A data acquisition system for a single-ring, high-resolution, small-animal PET scanner is described. This single-ring test system is part of the development of a multi-ring scanner. The system was designed to be as simple (short development cycle, and low cost) and as flexible as possible while maintaining high performance standards necessary for high-resolution quantitative studies. Unlike the multi-ring system electronics under developments the test system does not use a clock, but identifies coincidences by overlapping logic signals. The ring consists of up to 18 multi-crystal MiCE modules, each of which is coupled to a resistive summing board that produces two X and two Y position signals. These are sent to the inputs of an analog multiplexer circuit. Total energy signals are also produced and used as inputs to NIM discriminators. A field programmable gate array (FPGA) is used for all system logic functions. This allows software development, testing, implementation, and modification of logic circuitry without hardware modification. Inputs to the FPGA are the outputs of the 18 discriminators. The FPGA logic produces and locks an event signal whenever two modules along allowed lines of response trigger within a preset resolving time. The FPGA also produces detector codes identifying the detectors involved in the event. These are recorded and also sent to the multiplexer to switch the position signals from the modules involved in the event to a buffered CAMAC ADC system for digitization. A "not busy" signal from the ADC is used to reset the FPGA releasing the locked signals allowing further event acquisition.
[1]
Thomas K. Lewellen,et al.
Performance characteristics of a second generation micro crystal element (MiCE2) detector
,
2001,
2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310).
[2]
Thomas K. Lewellen,et al.
Performance characteristics of micro crystal element (MiCE) detectors
,
2000
.
[3]
Paul E. Kinahan,et al.
Design of a Firewire based data acquisition system for use in animal PET scanners
,
2001,
2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310).
[4]
J.W. Young,et al.
FPGA based front-end electronics for a high resolution PET scanner
,
1999,
1999 IEEE Nuclear Science Symposium. Conference Record. 1999 Nuclear Science Symposium and Medical Imaging Conference (Cat. No.99CH37019).
[5]
Robert S. Miyaoka,et al.
A data acquisition system for coincidence imaging using a conventional dual head gamma camera
,
1996
.