Geometric Changes in Aortic Endografts over a 2-Year Observation Period

Purpose: To report geometric changes in bifurcated aortic endografts observed over a 2-year follow-up period. Methods: Twenty-two patients (21 men; mean age 68 years, range 57–83) with abdominal aortic aneurysms were treated with an endovascular stent-graft. Follow-up examinations included spiral computed tomographic scanning postoperatively and at 3, 6, 9, 12, 18, and 24 months after treatment. Geometric changes were measured using 3-dimensional reconstructed images in anteroposterior (AP) and lateral projections. Locations for the measurements were the proximal neck, the midportion of the endograft, and the graft limbs at the origin of the iliac arteries. Results: Lateral changes predominated, demonstrating maximum angles on the side of the inserted left limb. For the proximal neck, the stent angle changed by a mean −0.71° in the AP and 4.0° in the lateral projection. At the midgraft, changes were −0.56° for AP and 12.5° for lateral. The right limb showed an angle of 6.43° in AP and −0.43° in lateral, whereas the left limb angles changed 1.38° in AP and 11.71° in the lateral plane after 2 years. There was no statistically significance difference in these changes from baseline. Conclusions: Aortic endografts are exposed to a significant amount of movement after insertion, but the resultant changes are very inhomogeneous, unpredictable, and ongoing even after 2 years. The most vulnerable location seems to be the attachment zone of the modular graft limb. These geometric changes might be one cause for late complications, including leaks and limb dislocations.

[1]  W. Stelter,et al.  Time-related alterations in shape, position, and structure of self-expanding, modular aortic stent-grafts: a 4-year single-center follow-up. , 1999 .

[2]  L. Sunder-Plassmann,et al.  Endovascular Repair of Aortic Aneurysms: Treatment of Complications , 1999, Journal of endovascular surgery : the official journal of the International Society for Endovascular Surgery.

[3]  F Beyersdorf,et al.  Endoluminal stent-grafts for infrarenal abdominal aortic aneurysms. , 1997, The New England journal of medicine.

[4]  T. Resch,et al.  Distal migration of stent-grafts after endovascular repair of abdominal aortic aneurysms. , 1999, Journal of vascular and interventional radiology : JVIR.

[5]  G. White,et al.  Surgical management of complications following endoluminal grafting of abdominal aortic aneurysms. , 1995, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[6]  J. Lammer,et al.  Treatment of abdominal aortic aneurysms with transfemoral placement of stent-grafts: complications and secondary radiologic intervention. , 1997, Radiology.

[7]  D. Gould,et al.  Longitudinal aneurysm shrinkage following endovascular aortic aneurysm repair: a source of intermediate and late complications. , 1999 .

[8]  W. Stelter,et al.  Time-Related Alterations in Shape, Position, and Structure of Self-Expanding, Modular Aortic Stent-Grafts: A 4-year Single-Center Follow-up , 1999, Journal of endovascular surgery : the official journal of the International Society for Endovascular Surgery.

[9]  W. Edwards,et al.  Technical complications of endovascular abdominal aortic aneurysm repair. , 1997, Journal of vascular surgery.