This paper reports details on the design of the Nd: glass laser facility NIXE at the Central Institute of Optics and Spectroscopy, including the target chamber and the x-ray diagnostics, spatial and temporal behaviour of the 1.06 μm radiation generated are given.
Plane, massive targets of aluminium and silicon have been irradiated with 6-nsec FWHM laser pulses.
Investigations of laser produced Al- and Si-plasmas have been performed with spectral and spatial high resolution diagnostics, consisting of a 3 channel crystal-spectrometer, 2 crystal-microscopes, and 2 pinhole cameras and the results are presented. Line spectra have been interpreted within the hypothesis of a steady state coronal equilibrium. He-like lines of the Al-plasma indicate temperatures up to 400 eV and densities up to 2 · 1020 cm−3. Total x-ray photon flux in the He-like resonance line has been calculated giving 1013 phot/ster.
Untersuchungen der Rontgenemission von Plasmen, die mit dem 6 nsec Nd:Glaslaser-System NIXE erzeugt wurden
Es werden detailliert das Nd:Glaslasersystem NIXE des Zentralinstituts fur Optik und Spektroskopie einschlieslich der Targetkammer und der Rontgendiagnostik beschrieben. Das raumliche und zeitliche Verhalten der 1,06 μm Strahlung wird angegeben. Ebene, massive Al- und Si-Targets wurden mit Impulsen der Halbwertsbreite von 6 nsec bestrahlt. Die Untersuchungen der lasererzeugten Al- und Si-Plasmen wurden mit spektral und raumlich hochauflosender Diagnostik, bestehend aus einem 3-Kanal-Kristallspektrometer, zwei Kristallmikroskopen und 2 Lochkameras durchgefuhrt und die Ergebnisse werden vorgestellt. Die Linienspektren werden im Rahmen eines stationaren Koronamodells interpretiert. He-ahnliche Linien des Al-Plasmas weisen auf Temperaturen bis zu 400 eV und Dichten bis zu 2 · 1020 cm−3 hin. Der totale Rontgenphotonenflus in der He-ahnlichen Resonanzlinie ist zu 1013 Phot/sterad abgeschatzt worden.