3-Phase 4-wire matrix converter-based voltage sag/swell generator to test low-voltage ride through in wind energy conversion systems

The high penetration of energy from wind energy conversion systems (WECSs) can have a significant influence on the stability, power quality and reliability of power systems. Therefore several countries have developed stringent grid codes in recent years in order to enhance the overall stability of power systems. In these grid codes, the capacity to fulfil low-voltage ride through (LVRT) requirements is considered an important issue for the control of WECSs. Therefore in this study, a novel voltage sag/ swell generator (VSG) based on a 4-leg matrix converter is presented. This VSG can be used to generate the symmetrical and asymmetrical faults required to test LVRT algorithms in a laboratory environment. The performance of the VSG is experimentally demonstrated and compared with the operation of other VSGs conventionally used for LVRT studies.

[1]  A. Alesina,et al.  Analysis and design of optimum-amplitude nine-switch direct AC-AC converters , 1989 .

[2]  Honghua Xu,et al.  Comparison of Voltage Sag Generators for Wind Power System , 2009, 2009 Asia-Pacific Power and Energy Engineering Conference.

[3]  P. Wheeler,et al.  The Application of Resonant Controllers to Four-Leg Matrix Converters Feeding Unbalanced or Nonlinear Loads , 2012, IEEE Transactions on Power Electronics.

[4]  G. H. Kwon,et al.  Voltage sag and swell generator with thyristor controlled reactor , 2002, Proceedings. International Conference on Power System Technology.

[5]  M. Venturini,et al.  Solid-state power conversion: A Fourier analysis approach to generalized transformer synthesis , 1981 .

[6]  R. Lohde,et al.  Transformer based voltage sag generator to perform LVRT and HVRT tests in the laboratory , 2010, Proceedings of 14th International Power Electronics and Motion Control Conference EPE-PEMC 2010.

[7]  Rong Zeng,et al.  A three-phase programmable voltage sag generator for low voltage ride-through capability test of wind turbines , 2010, 2010 IEEE Energy Conversion Congress and Exposition.

[8]  Johann W. Kolar,et al.  Comparative Evaluation of Three-Phase AC–AC Matrix Converter and Voltage DC-Link Back-to-Back Converter Systems , 2012, IEEE Transactions on Industrial Electronics.

[9]  José R. Rodríguez,et al.  Matrix converters: a technology review , 2002, IEEE Trans. Ind. Electron..

[10]  P.W. Wheeler,et al.  An Integrated 30kW Matrix Converter based Induction Motor Drive , 2005, 2005 IEEE 36th Power Electronics Specialists Conference.

[11]  Marcelo A. Perez,et al.  Vector Control of Front-End Converters for , 2006 .

[12]  R. Teodorescu,et al.  Overview of recent grid codes for wind power integration , 2010, 2010 12th International Conference on Optimization of Electrical and Electronic Equipment.

[13]  Roberto Cárdenas,et al.  Overview of control systems for the operation of DFIGs in wind energy applications , 2013, IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society.

[14]  Roberto Cárdenas,et al.  Analysis and Experimental Validation of Control Systems for Four-Leg Matrix Converter Applications , 2012, IEEE Transactions on Industrial Electronics.

[15]  Math Bollen Characterisation of voltage sags experienced by three-phase adjustable-speed drives , 1997 .

[16]  F. Blaabjerg,et al.  Benchmarking of Voltage Sag Generators , 2012, IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society.

[17]  Ahmet M. Hava,et al.  A simple sag generator using SSRs , 2010, 2010 IEEE Energy Conversion Congress and Exposition.

[18]  Mark Sumner,et al.  Microgrid unbalance compensator - Mitigating the negative effects of unbalanced microgrid operation , 2013, IEEE PES ISGT Europe 2013.

[19]  Stavros A. Papathanassiou,et al.  A review of grid code technical requirements for wind farms , 2009 .

[20]  José A. Sánchez,et al.  Voltage dip generator for testing wind turbines connected to electrical networks , 2011 .

[21]  A. Alesina,et al.  Intrinsic amplitude limits and optimum design of 9-switches direct PWM AC-AC converters , 1988, PESC '88 Record., 19th Annual IEEE Power Electronics Specialists Conference.

[22]  Humberto Pinheiro,et al.  Design of a voltage sag generator based on impedance switching , 2011, IECON 2011 - 37th Annual Conference of the IEEE Industrial Electronics Society.