Optimization of a tracer-based PLIF diagnostic for simultaneous imaging of EGR and temperature in IC engines

A tracer-based planar laser-induced fluorescence (TB-PLIF) imaging diagnostic using 3-pentanone has been optimized for use in IC engines. The diagnostic utilizes dual-wavelength excitation of 3-pentanone in the ultraviolet to make simultaneous measurements of exhaust gas residual mole fraction and temperature. A merit function based optimization of the diagnostic precision was performed which allowed for selection of optimal excitation wavelengths for the conditions of interest. Optimized system performance was validated in a motored optical engine over a wide range of in-cylinder temperatures and pressures. In-cylinder results verify the utility of the uncertainty estimates. Differences in magnitude between the estimated and measured precision were determined to be due to errors in parameter values used in the calculations. The observed 2.1% temperature precision at a temperature of 600 K was compared with previous TB-PLIF temperature measurements and shown to be approximately a factor of 2 better than previous results.

[1]  R. Hanson,et al.  Measurements and modeling of acetone laser-induced fluorescence with implications for temperature-imaging diagnostics. , 1998, Applied optics.

[2]  Ronald K. Hanson,et al.  Simultaneous Imaging of Exhaust Gas Residuals and Temperature During HCCI Combustion , 2009 .

[3]  Volker Sick,et al.  Tracer-LIF diagnostics: quantitative measurement of fuel concentration, temperature and fuel/air ratio in practical combustion systems , 2005 .

[4]  Jon Koch,et al.  Fuel tracer photophysics for quantitative planar laser-induced fluorescence , 2005 .

[5]  Ernest Otto Doebelin,et al.  Measurement Systems Application and Design , 1966 .

[6]  P. R. Bevington,et al.  Data Reduction and Error Analysis for the Physical Sciences , 1969 .

[7]  S. E. Bisson,et al.  Parametric study of an excimer-pumped, nitrogen Raman shifter for lidar applications. , 1995, Applied optics.

[8]  R. Steeper,et al.  Evaporation characteristics of the 3-pentanone–isooctane binary system , 2003 .

[9]  Volker Sick,et al.  Toluene laser-induced fluorescence for in-cylinder temperature imaging in internal combustion engines , 2008 .

[10]  P. Guibert,et al.  Influence of pressure, temperature and gas phase composition on biacetyl laser-induced fluorescence , 2006 .

[11]  Volker Sick,et al.  Measurement of temperature, fuel concentration and equivalence ratio fields using tracer LIF in IC engine combustion , 2000 .

[12]  M. Thurber Acetone laser-induced fluorescence for temperature and multiparameter imaging in gaseous flows , 1999 .

[13]  N Ladommatos,et al.  Optical diagnostics for in-cylinder mixture formation measurements in IC engines , 1998 .

[14]  Residual Gas Mixing in Engines , 2009 .

[15]  M. Aldén,et al.  Measurements of picosecond laser induced fluorescence from gas phase 3-pentanone and acetone: Implications to combustion diagnostics , 1997 .

[16]  V. Mitev,et al.  Experimental investigation of high-power single-pass Raman shifters in the ultraviolet with Nd:YAG and KrF lasers. , 1997, Applied optics.

[17]  R. Hanson,et al.  Temperature imaging with single- and dual-wavelength acetone planar laser-induced fluorescence. , 1997, Optics letters.

[18]  R. Hanson,et al.  High resolution digital flowfield imaging of jets , 1990 .

[19]  R. Hanson,et al.  Absorption and fluorescence of toluene vapor at elevated temperatures , 2004 .

[20]  A Frenkel,et al.  Photon-noise-limited operation of intensified CCD cameras. , 1997, Applied optics.

[21]  R. Howe,et al.  Quantitative flow visualization technique for measurements in combustion gases. , 1984, Applied optics.

[22]  A. John Mallinckrodt,et al.  Data Reduction and Error Analysis for the Physical Sciences , 1993 .