Single-atom optical clock with high accuracy.

For the past 50 years, atomic standards based on the frequency of the cesium ground-state hyperfine transition have been the most accurate time pieces in the world. We now report a comparison between the cesium fountain standard NIST-F1, which has been evaluated with an inaccuracy of about 4 x 10(-16), and an optical frequency standard based on an ultraviolet transition in a single, laser-cooled mercury ion for which the fractional systematic frequency uncertainty was below 7.2 x 10(-17). The absolute frequency of the transition was measured versus cesium to be 1,064,721,609,899,144.94 (97) Hz, with a statistically limited total fractional uncertainty of 9.1 x 10(-16) the most accurate absolute measurement of an optical frequency to date.

[1]  Theodor W. Hänsch,et al.  Absolute Optical Frequency Measurement of the Cesium D 1 Line with a Mode-Locked Laser , 1999 .

[2]  Jon H. Shirley,et al.  Accuracy evaluation of NIST-F1 , 2002 .

[3]  David J. Wineland,et al.  Minimization of ion micromotion in a Paul trap , 1998 .

[4]  A Bartels,et al.  Generation of a broadband continuum by a Ti:sapphire femtosecond oscillator with a 1-GHz repetition rate. , 2002, Optics letters.

[5]  Jon H. Shirley,et al.  NIST-F1: recent improvements and accuracy evaluations , 2005 .

[6]  Flavio C. Cruz,et al.  VISIBLE LASERS WITH SUBHERTZ LINEWIDTHS , 1999 .

[7]  R. Wynands,et al.  Atomic fountain clocks , 2005 .

[8]  J. V. L. PARRY,et al.  An Atomic Standard of Frequency and Time Interval: A Cæsium Resonator , 1955, Nature.

[9]  L. Hollberg,et al.  Phase-coherent link from optical to microwave frequencies by means of the broadband continuum from a 1-GHz Ti:sapphire femtosecondoscillator. , 2002, Optics letters.

[10]  E. A. Curtis,et al.  An Optical Clock Based on a Single Trapped 199Hg+ Ion , 2001, Science.

[11]  W. Itano,et al.  Measurement of the (199)Hg+ 5d9 6s2 (2)D(5/2) electric quadrupole moment and a constraint on the quadrupole shift. , 2005, Physical review letters.

[12]  B Lipphardt,et al.  Limit on the present temporal variation of the fine structure constant. , 2004, Physical review letters.

[13]  W M Itano,et al.  Testing the stability of fundamental constants with the 199Hg+ single-ion optical clock. , 2003, Physical review letters.

[14]  Wayne M. Itano,et al.  External-Field Shifts of the 199Hg+ Optical Frequency Standard , 2000, Journal of research of the National Institute of Standards and Technology.

[15]  M. G. Boshier,et al.  Destabilization of dark states and optical spectroscopy in Zeeman-degenerate atomic systems , 2002 .

[16]  T Schneider,et al.  Sub-Hertz optical frequency comparisons between two trapped 171Yb+ ions. , 2005, Physical review letters.

[17]  P. Gill,et al.  Hertz-Level Measurement of the Optical Clock Frequency in a Single 88Sr+ Ion , 2004, Science.

[18]  J. Bernard,et al.  Electric quadrupole shift cancellation in single-ion optical frequency standards. , 2005, Physical review letters.

[19]  Steven R. Jefferts,et al.  Operation of the NIST-F1 caesium fountain primary frequency standard with a maser ensemble, including the impact of frequency transfer noise , 2005 .

[20]  Hall,et al.  Direct link between microwave and optical frequencies with a 300 THz femtosecond laser comb , 2000, Physical review letters.

[21]  D. Percival,et al.  Total variance, an estimator of long-term frequency stability [standards] , 1999, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[22]  P. Gill Optical frequency standards , 2005 .

[23]  H. Dehmelt,et al.  Monoion oscillator as potential ultimate laser frequency standard , 1982, IEEE Transactions on Instrumentation and Measurement.

[24]  David J. Wineland,et al.  Laser-Cooled Mercury Ion Frequency Standard , 1998 .

[25]  Scott A. Diddams,et al.  Optical Frequency Synthesis and Comparison with Uncertainty at the 10-19 Level , 2004, Science.