Ultrasonic interrogation of tissue vibrations in arterial and organ injuries: preliminary in vivo results.

Soft tissues surrounding vascular injuries are known to vibrate at audible and palpable frequencies, producing bruits and thrills. We report the results of a feasibility study where Doppler ultrasound (US) was used to quantitatively estimate the tissue vibrations after induced trauma in an animal model. A software-programmable US system was used to acquire quadrature-demodulated ensembles of received US echoes bypassing clutter filtering and other conventional Doppler processing stages. The waveforms of tissue velocity surrounding the injury site were then estimated from the clutter data using autocorrelation and analyzed to determine vibration characteristics. Six New Zealand white rabbits and two juvenile pigs were used for the study. The femoral artery of the anesthetized animal was punctured with an 18-gauge needle to model a peripheral arterial trauma, and the liver was surgically exposed and incised to model organ trauma. Two types of oscillatory tissue motion were observed: "vibrations" with high frequency (>50 Hz) and low peak-peak amplitude (<1 microm) and "flutter" with low frequency (<50 Hz) and high peak-peak amplitude (>1 microm). Active bleeding in femoral artery punctures produced tissue vibrations at the frequency of 323 +/- 214 Hz (mean +/- standard deviation, pooled for both rabbits and pigs) and the amplitude of 0.24 +/- 0.15 microm. Active bleeding in liver incisions produced vibrations at the frequency of 120 +/- 47 Hz and the amplitude of 0.33 +/- 0.25 microm. Flutter was observed in punctured arteries at the frequency of 28 +/- 13 Hz the amplitude of 2.92 +/- 1.75 microm, and in incised livers at the frequency of 26 +/- 6 Hz and the amplitude of 1.53 +/- 0.76 microm. In a punctured artery, the vibration frequency and phase of tissue surrounding the artery were highly correlated between neighboring locations in tissue (correlation coefficient = 0.98), and with the flow oscillations in the lumen (correlation coefficient = 0.96). This preliminary study indicates that tissue vibrations could provide additional physiologic information for detecting, localizing and monitoring internal bleeding using US.

[1]  D. Liepsch,et al.  Recording of unexpectedly high frequency vibrations of blood vessel walls in experimental arteriovenous fistulae of rabbits using a laser vibrometer. , 1995, Biorheology.

[2]  D. Merton,et al.  Contrast‐Enhanced Two‐ and Three‐dimensional Sonography for Evaluation of Intra‐abdominal Hemorrhage , 2002, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[3]  K. Hutchison,et al.  Arterial Wall Vibration Distal to Stenoses in Isolated Arteries of Dog and Man , 1970, Circulation research.

[4]  Yongmin Kim,et al.  Ultrasonic technique for imaging tissue vibrations: preliminary results. , 2005, Ultrasound in medicine & biology.

[5]  H. C. Veldenz,et al.  Continued experience with physical examination alone for evaluation and management of penetrating zone 2 neck injuries: results of 145 cases. , 2000, Journal of vascular surgery.

[6]  G. Casola,et al.  Blunt abdominal trauma: clinical value of negative screening US scans. , 2004, Radiology.

[7]  N R Cholvin,et al.  Wall vibrations induced by flow through simulated stenosis in models and arteries. , 1977, Journal of biomechanics.

[8]  Lawrence E. Kinsler,et al.  Fundamentals of acoustics , 1950 .

[9]  S. Offerman,et al.  Clinical importance of intraperitoneal fluid in patients with blunt intra-abdominal injury. , 2002, The American journal of emergency medicine.

[10]  K. Beach,et al.  Transcutaneous localization of arterial bleeding by two-dimensional ultrasonic imaging of tissue vibrations , 2003, IEEE Symposium on Ultrasonics, 2003.

[11]  T. Dubinsky,et al.  High-intensity focused ultrasound: current potential and oncologic applications. , 2008, AJR. American journal of roentgenology.

[12]  G. Casola,et al.  Blunt abdominal trauma: screening us in 2,693 patients. , 2001, Radiology.

[13]  K. Klose,et al.  Color Doppler sonography in penetrating injuries of the neck. , 1996, AJNR. American journal of neuroradiology.

[14]  Y. Yamakoshi,et al.  Ultrasonic imaging of internal vibration of soft tissue under forced vibration , 1990, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[15]  M. Dolich,et al.  2,576 ultrasounds for blunt abdominal trauma. , 2001, The Journal of trauma.

[16]  D. Winestock,et al.  The clinical indications for arteriography in trauma to the extremity. A review of 114 cases. , 1975, Radiology.

[17]  J. Holen,et al.  Representations of rapidly oscillating structures on the Doppler display. , 1985, Ultrasound in medicine & biology.

[18]  Shahram Vaezy,et al.  Therapeutic Ultrasound, Part II * . High Intensity Focused Ultrasound: A Method of Hemostasis , 2001, Echocardiography.

[19]  F. W. Blaisdell,et al.  Chapter 5 – Diagnosis of Vascular Trauma , 2004 .

[20]  B E Brink,et al.  Vascular trauma. , 1977, The Surgical clinics of North America.

[21]  G. Rozycki,et al.  Blunt vascular trauma in the extremity: diagnosis, management, and outcome. , 2003, The Journal of trauma.

[22]  Michael F. O'Rourke,et al.  McDonald's blood flow in arteries : theoretic, experimental, and clinical principles , 1990 .

[23]  R. Lees,et al.  Evaluation of carotid stenosis by phonoangiography. , 1975, The New England journal of medicine.

[24]  W D Middleton,et al.  Perivascular color artifact: pathologic significance and appearance on color Doppler US images. , 1989, Radiology.

[25]  W. Nichols,et al.  McDonald's Blood Flow in Arteries: Theoretical, Experimental and Clinical Principles , 1998 .

[26]  H. Torp,et al.  Ultrasound doppler measurements of low velocity blood flow: limitations due to clutter signals from vibrating muscles , 1997, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[27]  W. Nichols McDonald's Blood Flow in Arteries , 1996 .

[28]  R. Martin,et al.  Hemostasis of punctured vessels using Doppler-guided high-intensity ultrasound. , 1999, Ultrasound in medicine & biology.

[29]  J. Hogg Magnetic resonance imaging. , 1994, Journal of the Royal Naval Medical Service.

[30]  J. McGahan,et al.  The Focused Abdominal Sonography for Trauma Scan , 2002, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[31]  R. Lees,et al.  Phonoangiography: a new noninvasive diagnostic method for studying arterial disease. , 1970, Proceedings of the National Academy of Sciences of the United States of America.

[32]  Tetsuya Hayashi,et al.  A single mediaprocessor-based programmable ultrasound system , 2003, IEEE Transactions on Information Technology in Biomedicine.

[33]  J. Polak,et al.  Arterial injuries: a sonographic approach. , 2004, Radiologic clinics of North America.

[34]  D. Ku,et al.  Effect of stenosis on wall motion. A possible mechanism of stroke and transient ischemic attack. , 1989, Arteriosclerosis.

[35]  F. Logerfo,et al.  A Comprehensive Approach to Extremity Vascular Trauma , 1985 .

[36]  Michael Leitch,et al.  Magnetic resonance imaging of shear wave propagation in excised tissue , 1998, Journal of magnetic resonance imaging : JMRI.

[37]  K W Beach,et al.  In vivo ultrasonic measurement of tissue vibration at a stenosis: a case study. , 2001, Ultrasound in medicine & biology.

[38]  Melani Plett,et al.  Ultrasonic vibration dectection with wavelets: preliminary results. , 2005, Ultrasound in medicine & biology.