Full-scale model tests and nonlinear analysis of prestressed concrete simply supported box girders

Full-scale model tests were carried out on a 30 m span prestressed concrete box girder and a 20 m span prestressed concrete hollow slab. Failure models were prestressed reinforcement tensile failure and crushing of roof concrete,respectively. The ductility indexes of the box girder and hollow slab were 1.99 and 1.23, respectively,according to the energy viewpoint. Based on the horizontal section hypothesis,the nonlinear computation procedure was established using the limited banding law,and it could carry out the entire performance analysis including the unloading,mainly focusing on the ways to achieve the unloading curves computation through stress-strain,moment-curvature and load-displacement curves. Through the procedure,parameters that influence on the bearing capacity,deformation performance and ductility of the structures were analyzed. Those parameters were quantity of prestressed reinforcement and tension coefficients of prestressed reinforcement. From the analysis,some useful conclusions can be obtained.