Ultrasonic longitudinal waves to monitor the integration of titanium rods with host bone

Osseointegrated prostheses which integrate the prosthesis directly to the limb bone are being developed for patients that are unable to wear traditional socket prostheses. While osseointegration of the prosthesis offers amputees improvement in their quality of life, there remains a need to better understand the integration process that occurs between the bone and the prosthesis. Quantification of the degree of integration is important to track the recuperation process of the amputee, guide physical therapy regimes, and to identify when the state of integration may change (due to damage to the bone). This study explores the development of an assessment strategy for quantitatively assessing the degree of integration between an osseointegrated prosthesis and host bone. Specifically, the strategy utilizes a titanium rod prosthesis as a waveguide with guided waves used to assess the degree of integration. By controlling waveforms launched by piezoelectric wafers bonded on the percutaneous tip of the prosthesis, body waves are introduced into the waveguide with wave reflections at the boneprosthesis interface recorded by the same array. Changes in wave energy are correlated to changes at the contact interface between the titanium rod and the bone material. Both simulation and experimental tests are presented in this paper. Experimental testing is performed using a high-density polyethylene (HDPE) host because the elastic modulus and density of HDPE are close to that of human and animal bone. Results indicate high sensitivity of the longitudinal wave energy to rod penetration depth and confinement stress issued by the host bone.

[1]  J. Currey,et al.  Young's modulus, density and material properties in cancellous bone over a large density range , 1992 .

[2]  J. Sullivan,et al.  Rehabilitation of the transfemoral amputee with an osseointegrated prosthesis: The United Kingdom experience , 2003, Prosthetics and orthotics international.

[3]  Wenwu Cao,et al.  Measurements of face shear properties in relaxor-PbTiO3 single crystals , 2011 .

[4]  John Sullivan,et al.  Monitoring of the load regime applied on the osseointegrated fixation of a trans-femoral amputee: A tool for evidence-based practice , 2008, Prosthetics and orthotics international.

[5]  Wei Xu,et al.  X-Ray Image Review of the Bone Remodeling Around an Osseointegrated Trans-femoral Implant and a Finite Element Simulation Case Study , 2008, Annals of Biomedical Engineering.

[6]  S Sawamura,et al.  The efficacy of physiological cost index (PCI) measurement of a subject walking with an Intelligent Prosthesis , 1999, Prosthetics and orthotics international.

[7]  Evans,et al.  MEMS Capacitive Strain Sensing Elements for Integrated Total Knee Arthroplasty Prosthesis Monitoring , 2007 .

[8]  K. Hagberg,et al.  Osseointegrated Titanium Implants for Limb Prostheses Attachments: Infectious Complications , 2010, Clinical orthopaedics and related research.

[10]  T. Mazúch,et al.  Wave Dispersion Modelling in Anisotropic Shells and Rods by the Finite Element Method , 1996 .

[11]  J. Rose,et al.  Guided wave dispersion curves for a bar with an arbitrary cross-section, a rod and rail example. , 2003, Ultrasonics.

[12]  J. Rose Ultrasonic Waves in Solid Media , 1999 .

[13]  Renaldas Raisutis,et al.  Application of ultrasonic guided waves for non-destructive testing of defective CFRP rods with multiple delaminations , 2010 .

[14]  J. Lewsey,et al.  Continuous monitoring of the performance of hip prostheses. , 2006, The Journal of bone and joint surgery. British volume.

[15]  Oguz Atasoy,et al.  Instrumented prosthesis for knee implants monitoring , 2011, 2011 IEEE International Conference on Automation Science and Engineering.

[16]  Wensong Zhou,et al.  In-plane shear piezoelectric wafer active sensor phased arrays for structural health monitoring , 2016, SPIE Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring.