Analysis on load-factor dependence of triple active bridge converter's transmission efficiency for autonomous power networks

A hybrid AC/DC microgrid systems that uses a triple active bridge (TAB) converter as a power routing unit has been proposed. Since the demand and supply balance of power fluctuates in the microgrid system, the power handled by the TAB converter also varies with time. Therefore, a TAB converter with a small load-factor dependence of transmission efficiency is necessary to reduce the unit's overall loss and design highly efficient microgrid systems. We previously fabricated a prototype TAB converter rated at 400 V, 20 kHz, and 10 kW using SiC-MOSFETs and demonstrated that it can control transmission power. In this study, the load-factor dependence of the TAB converter's transmission efficiency was investigated based on experimental results. The results show that the transmission efficiency of the TAB converter decreased under low-load conditions such as a load factor of less than 20%. In addition, the loss components involved in this dependence was analyzed. The analysis results indicate that switching loss is the main component of transmission-efficiency degradation under low-load conditions.

[1]  Yuichi Kado,et al.  Implementation and performance of three-way isolated DC/DC converter using SiC-MOSFETs for power flow control , 2016, 2016 IEEE 7th International Symposium on Power Electronics for Distributed Generation Systems (PEDG).

[2]  A Q Huang,et al.  The Future Renewable Electric Energy Delivery and Management (FREEDM) System: The Energy Internet , 2011, Proceedings of the IEEE.

[3]  Subhashish Bhattacharya,et al.  Energy router: Architectures and functionalities toward Energy Internet , 2011, 2011 IEEE International Conference on Smart Grid Communications (SmartGridComm).

[4]  Koya Nishimoto,et al.  Decoupling power flow control system in triple active bridge converter rated at 400 V, 10 kW, and 20 kHz , 2017, 2017 IEEE 8th International Symposium on Power Electronics for Distributed Generation Systems (PEDG).

[5]  J.W. Kolar,et al.  An Isolated Three-Port Bidirectional DC-DC Converter With Decoupled Power Flow Management , 2008, IEEE Transactions on Power Electronics.

[6]  Katsumi Iwatsuki,et al.  Multiport power router and its impact on future smart grids , 2016 .

[7]  Keiji Wada,et al.  Loss Analysis of Magnetic Components for a Solid-State-Transformer , 2015 .

[8]  Nakagawa Shota,et al.  Power loss analysis of 10kW three-way isolated DC/DC converter using SiC-MOSFETs as a power routing unit for constructing 400V DC microgrid systems , 2016 .

[9]  Rikiya Abe,et al.  Digital Grid: Communicative Electrical Grids of the Future , 2011, IEEE Trans. Smart Grid.

[10]  Junichi Toyoda,et al.  A Study on Autonomous Decentralized Control Mechanism of Power Flow in Open Electric Energy Network , 1997 .

[11]  Koya Nishimoto,et al.  Implementation and power-loss characteristics of 400-V, 10-kW, 20-kHz three-way isolated DC/DC converter as a power routing unit for constructing microgrid systems , 2016, 2016 IEEE Region 10 Conference (TENCON).

[12]  J.W. Kolar,et al.  A novel three-phase three-port UPS employing a single high-frequency isolation transformer , 2004, 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551).

[13]  Koya Nishimoto,et al.  Dynamic performance of triple-active bridge converter rated at 400 V, 10 kW, and 20 kHz , 2017, 2017 IEEE 3rd International Future Energy Electronics Conference and ECCE Asia (IFEEC 2017 - ECCE Asia).