Morphological Approach for the Functional Improvement of an Artificial Myocardial Assist Device using Shape Memory Alloy Fibres

The authors have been developing a mechano-electric artificial myocardial assist system (artificial myocardium) which is capable of supporting natural contractile functions from the outside of the ventricle without blood contacting surface. In this study, a nano-tech covalent type shape memory alloy fibre (Biometal, Toki Corp, Japan) was employed and the parallel-link structured myocardial assist device was developed. And basic characteristics of the system were examined in a mechanical circulatory system as well as in animal experiments using goats. The contractile functions were evaluated with the mock circulatory system that simulated systemic circulation with a silicone left ventricular model and an aortic afterload. Hemodynamic performance was also examined in goats. Prior to the measurement, the artificial myocardial assist device was installed into the goat's thoracic cavity and attached onto the ventricular wall. As a result, the system could be installed successfully without severe complications related to the heating, and the aortic flow rate was increased by 15% and the systolic left ventricular pressure was elevated by 7% under the cardiac output condition of 3L/min in a goat. And those values were elevated by the improvement of the design which was capable of the natural morphological myocardial tissue streamlines. Therefore it was indicated that the effective assistance might be achieved by the contraction by the newly-designed artificial myocardial assist system using Biometal. Moreover it was suggested that the assistance gain might be obtained by the optimised configuration design along with the natural anatomical myocardial stream line.

[1]  Masashi Komeda,et al.  Towards new understanding of the heart structure and function. , 2005, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[2]  M. Yoshizawa,et al.  Development of an Artificial Myocardium using a Covalent Shape-memory Alloy Fiber and its Cardiovascular Diagnostic Response , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[3]  Y. Saijo,et al.  An Innovative Approach to Evaluate a Cardiac Function Based on Surface Measurement , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[4]  Masayoshi Esashi,et al.  Addition of rhythm to non-pulsatile circulation. , 2004, Biomedicine & pharmacotherapy = Biomedecine & pharmacotherapie.

[5]  Mitsuo Umezu,et al.  An artificial myocardium assist system: electrohydraulic ventricular actuation improves myocardial tissue perfusion in goats. , 2004, Artificial organs.

[6]  Masayoshi Esashi,et al.  Artificial myocardium with an artificial baroreflex system using nano technology. , 2003, Biomedicine & pharmacotherapy = Biomedecine & pharmacotherapie.

[7]  Mitsuo Umezu,et al.  Fabrication of Pulsatile Cardiac Tissue Grafts Using a Novel 3-Dimensional Cell Sheet Manipulation Technique and Temperature-Responsive Cell Culture Surfaces , 2002, Circulation research.

[8]  F. Torrent-Guasp Estructura y función del corazón , 1998 .

[9]  R. Novick,et al.  The Registry of the International Society for Heart and Lung Transplantation: fifteenth official report--1998. , 1998, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[10]  F Torrent-Guasp,et al.  [Structure and function of the heart]. , 1998, Revista espanola de cardiologia.

[11]  H Suga,et al.  Dynamic cardiac compression improves contractile efficiency of the heart. , 1997, The Journal of thoracic and cardiovascular surgery.

[12]  S. K. Khanna Direct mechanical ventricular actuation. , 1993, The Annals of thoracic surgery.

[13]  J. Lowe,et al.  Direct mechanical ventricular actuation: a review. , 1991, Resuscitation.

[14]  D. Honma,et al.  SHAPE MEMORY EFFECT IN Ti-Ni ALLOY DURING RAPID HEATING. , 1982 .

[15]  N Ramasamy,et al.  FURTHER STUDY OF NITINOL WIRE AS CONTRACTILE ARTIFICIAL MUSCLE FOR AN ARTIFICIAL HEART. , 1976, Cardiovascular diseases.

[16]  J. V. Gilfrich,et al.  Effect of Low‐Temperature Phase Changes on the Mechanical Properties of Alloys near Composition TiNi , 1963 .