Comparison of Motor Bearing Currents with PWM and Soft Switched Voltage Source Inverters

This paper compares motor hearing currents due to PWM hard switched and soft switched inverters. The mechanisms for bearing currents are first identified using an approach based on direct excitation of the motor bearing with sinusoidal and square-wave signals to characterize the bearings. It is shown that many of the motor models that have been proposed in the literature to explain bearing currents do not adequately explain the observed higher frequency effects. The paper also outlines some of the important phenomena which need to be considered for a more complete description of bearing currents. Finally, the paper compares the performance of hard and soft switched inverters with respect to bearing currents. Experimental results are provided for PWM hard switched and soft switched IGBT inverters which have exactly same power circuit layout, identical chassis and rating of 70 kW.

[1]  A. H. Bonnett,et al.  Analysis of the impact of pulse-width modulated inverter voltage waveforms on AC induction motors , 1994, Proceedings of IEEE Pulp and Paper Industry Conference.

[2]  P. L. Alger,et al.  Shaft currents in electric machines , 1923, Journal of the American Institute of Electrical Engineers.

[3]  T.G. Habetler,et al.  Performance characterization of a new discrete pulse modulated current regulator , 1988, Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting.

[4]  Thomas A. Lipo,et al.  Modeling of motor bearing currents in PWM inverter drives , 1995 .

[5]  Doyle F. Busse,et al.  Bearing currents and their relationship to PWM drives , 1995, Proceedings of IECON '95 - 21st Annual Conference on IEEE Industrial Electronics.

[6]  Doyle F. Busse,et al.  The effects of PWM voltage source inverters on the mechanical performance of rolling bearings , 1996, Proceedings of Applied Power Electronics Conference. APEC '96.

[7]  K. Reichert,et al.  Shaft voltages in generators with static excitation systems-problems and solution , 1988 .

[8]  D.K. Sharma,et al.  Measured Winding Impedances of a Large A-C Motor , 1987, IEEE Transactions on Energy Conversion.

[9]  Doyle F. Busse,et al.  System electrical parameters and their effects on bearing currents , 1996, Proceedings of Applied Power Electronics Conference. APEC '96.

[10]  T. S. Lauber,et al.  Prestriking voltages associated with motor breaker closing , 1988 .