Automated correction of unwanted phase jumps in reference signals which corrupt MRSI spectra after eddy current correction.

A commonly applied step in the postprocessing of gradient localized proton MR spectroscopy, is correction for eddy current effects using the water signal as a reference. However, this method can degrade some of the metabolite signals, in particular if applied on proton MR spectroscopic imaging data. This artifact arises from the water reference signal in the presence of a second signal which resonates close to the main water resonance. The interference of both resonances will introduce jumps in the phase of the reference time domain signal. Using this phase for eddy current correction will result in a ringing artifact in the frequency domain of the metabolite signal over the whole frequency range. We propose a moving window correction algorithm, which screens the phase of reference signals and removes phase jumps in time domain caused by interference of signals from multiple spin systems. The phase jumps may be abrupt or gradually distributed over several time data points. Because the correction algorithm only corrects time data points which contain phase jumps, the phase is minimally disrupted. Furthermore, the algorithm is automated for large datasets, correcting only those water reference signals which are corrupted. After correction of the corrupted reference signals, normal eddy current correction may be performed. The algorithm is compared with a method which uses a low-pass filter and tested on simulated data as well as on in vivo proton spectroscopic imaging data from a healthy volunteer and from patients with a brain tumor.

[1]  S. Huffel,et al.  MR spectroscopy quantitation: a review of time‐domain methods , 2001, NMR in biomedicine.

[2]  de Beer R,et al.  LeuvenDepartement Elektrotechniek ESAT-SISTA / TR 1997-89 Fast removal of residual water in proton spectra 1 , 2022 .

[3]  M W Weiner,et al.  Automated processing for proton spectroscopic imaging using water reference deconvolution , 1994, Magnetic resonance in medicine.

[4]  A. Webb,et al.  Reference deconvolution: a simple and effective method for resolution enhancement in nuclear magnetic resonance spectroscopy , 2000 .

[5]  John S. Leigh,et al.  Errors of fourier chemical-shift imaging and their corrections , 1991 .

[6]  Gareth A. Morris,et al.  Compensation of instrumental imperfections by deconvolution using an internal reference signal , 1988 .

[7]  Roger J. Ordidge,et al.  THE CORRECTION OF TRANSIENT B0 FIELD SHIFTS FOLLOWING THE APPLICATION OF PULSED GRADIENTS BY PHASE CORRECTION IN THE TIME DOMAIN , 1986 .

[8]  J. Wild Artifacts introduced by zero order phase correction in proton NMR spectroscopy and a method of elimination by phase filtering. , 1999, Journal of magnetic resonance.

[9]  Matthew O'Donnell,et al.  Correction of phase effects produced by eddy currents in solvent suppressed 1H‐CSI , 1993, Magnetic resonance in medicine.

[10]  S. Provencher Estimation of metabolite concentrations from localized in vivo proton NMR spectra , 1993, Magnetic resonance in medicine.

[11]  U. Klose In vivo proton spectroscopy in presence of eddy currents , 1990, Magnetic resonance in medicine.

[12]  A Heerschap,et al.  Common processing of in vivo MR spectra , 2001, NMR in biomedicine.

[13]  G. Morris,et al.  REFERENCE DECONVOLUTION USING MULTIPLET REFERENCE SIGNALS , 1995 .