Third-generation blood pumps with mechanical noncontact magnetic bearings.

This article reviews third-generation blood pumps, focusing on the magnetic-levitation (maglev) system. The maglev system can be categorized into three types: (i) external motor-driven system, (ii) direct-drive motor-driven system, and (iii) self-bearing or bearingless motor system. In the external motor-driven system, Terumo (Ann Arbor, MI, U.S.A.) DuraHeart is an example where the impeller is levitated in the axial or z-direction. The disadvantage of this system is the mechanical wear in the mechanical bearings of the external motor. In the second system, the impeller is made into the rotor of the motor, and the magnetic flux, through the external stator, rotates the impeller, while the impeller levitation is maintained through another electromagnetic system. The Berlin Heart (Berlin, Germany) INCOR is the best example of this principle where one-axis control combination with hydrodynamic force achieves high performance. In the third system, the stator core is shared by the levitation and drive coil to make it as if the bearing does not exist. Levitronix CentriMag (Zürich, Switzerland), which appeared recently, employs this concept to achieve stable and safe operation of the extracorporeal system that can last for a duration of 14 days. Experimental systems including HeartMate III (Thoratec, Woburn, MA, U.S.A.), HeartQuest (WorldHeart, Ottawa, ON, Canada), MagneVAD (Gold Medical Technologies, Valhalla, NY, U.S.A.), MiTiHeart (MiTi Heart, Albany, NY, U.S.A.), Ibaraki University's Heart (Hitachi, Japan) and Tokyo Medical and Dental University/Tokyo Institute of Technology's disposable and implantable maglev blood pumps are also reviewed. In reference to second-generation blood pumps, such as the Jarvik 2000 (Jarvik Heart, New York, NY, U.S.A.), which is showing remarkable achievement, a question is raised whether a complicated system such as the maglev system is really needed. We should pay careful attention to future clinical outcomes of the ongoing clinical trials of the second-generation devices before making any further remarks. What is best for patients is the best for everyone. We should not waste any efforts unless they are actually needed to improve the quality of life of heart-failure patients.

[1]  Toru Masuzawa,et al.  Magnetically suspended centrifugal blood pump with a self bearing motor. , 2001 .

[2]  James F. Walton,et al.  Testing of a Centrifugal Blood Pump With a High Efficiency Hybrid Magnetic Bearing , 2003, ASAIO journal.

[3]  R. Lafaro,et al.  Magnevad status of design improvements human blood results and preliminary sheep trial. , 2005, Artificial organs.

[4]  J. Pepper,et al.  Clinical performance with the Levitronix Centrimag short-term ventricular assist device. , 2006, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[5]  Gill B Bearnson,et al.  HeartQuest ventricular assist device magnetically levitated centrifugal blood pump. , 2006, Artificial organs.

[6]  James F. Antaki,et al.  DESIGN OPTIMIZATION OF THE HEARTQUEST MAGLEV VAD , 2001 .

[7]  Satoshi Saito,et al.  First permanent implant of the Jarvik 2000 Heart , 2000, The Lancet.

[8]  Yukihiko Nosé,et al.  Clarence Dennis, 1909–2005: Innovator, Nurturer . . . Pillar of Integrity , 2006 .

[9]  Tadahiko Shinshi,et al.  Magnetically Suspended Centrifugal Blood Pump With a Radial Magnetic Driver , 2005, ASAIO journal.

[10]  Ludwig K von Segesser,et al.  No drive line, no seal, no bearing and no wear: magnetics for impeller suspension and flow assessment in a new VAD. , 2004, Interactive cardiovascular and thoracic surgery.

[11]  A. Besarab,et al.  Detection of Access Strictures and Outlet Stenoses in Vascular Accesses Which Test Is Best? , 1997, ASAIO journal.

[12]  R Kiraly,et al.  Comparative evaluation of nonpulsatile and pulsatile cardiac prostheses. , 1980, Transactions - American Society for Artificial Internal Organs.

[13]  Tadahiko Shinshi,et al.  Disposable magnetically levitated centrifugal blood pump: design and in vitro performance. , 2005, Artificial organs.

[14]  T Akutsu,et al.  Recent progress in the development of Terumo implantable left ventricular assist system. , 1999, ASAIO journal.

[15]  Tadahiko Shinshi,et al.  A compact highly efficient and low hemolytic centrifugal blood pump with a magnetically levitated impeller. , 2006, Artificial organs.

[16]  H Harasaki,et al.  Chronic nonpulsatile blood flow in an alive, awake animal 34-day survival. , 1980, Transactions - American Society for Artificial Internal Organs.

[17]  Georg Wieselthaler,et al.  293: Initial results of a European multicenter clinical trial with the DuraHeart® Mag-Lev centrifugal left ventricular assist device , 2006 .

[18]  Toru Masuzawa,et al.  Axial type self-bearing motor for axial flow blood pump. , 2003, Artificial organs.

[19]  Toru Masuzawa,et al.  Novel Maglev Pump With a Combined Magnetic Bearing , 2005, ASAIO journal.

[20]  Teruaki Akamatsu,et al.  OVER NINE MONTHS CONTINUOUS OPERATION OF A CENTRIFUGAL PUMP WITH A MAGNETICALLY SUSPENDED IMPELLER IN A SHEEP , 1997 .

[21]  Tadahiko Shinshi,et al.  Detection of left ventricle function from a magnetically levitated impeller behavior. , 2006, Artificial organs.

[22]  Christoph Schmidt,et al.  First clinical experience with the Incor left ventricular assist device. , 2005, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[23]  D B Olsen,et al.  Prototype Continuous Flow Ventricular Assist Device Supported on Magnetic Bearings. , 1996, Artificial organs.

[24]  T Akutsu,et al.  Terumo implantable left ventricular assist system: results of long-term animal study. , 2000, ASAIO journal.

[25]  T Akamatsu,et al.  Centrifugal blood pump with a magnetically suspended impeller. , 1992, Artificial organs.

[26]  Reto Schöb Centrifugal pump without bearings or seals , 2002 .

[27]  Natale Barletta,et al.  Incorporation of electronics within a compact, fully implanted left ventricular assist device. , 2002, Artificial organs.

[28]  Roland Hetzer,et al.  First experiences with a novel magnetically suspended axial flow left ventricular assist device. , 2004, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[29]  H. Harasaki,et al.  Chronic nonpulsatile blood flow. , 1982, Transactions - American Society for Artificial Internal Organs.

[30]  T. Tsukiya,et al.  Recent studies of the centrifugal blood pump with a magnetically suspended impeller. , 1995, Artificial organs.

[31]  J. Beams Magnetic Suspension for Small Rotors , 1950 .

[32]  M Komeda,et al.  Results of chronic animal experiments with a new version of a magnetically suspended centrifugal pump. , 1998, ASAIO journal.

[33]  Michael Goldowsky Magnevad--the world's smallest magnetic-bearing turbo pump. , 2004, Artificial organs.

[34]  M Kameneva,et al.  The Heartmate III: design and in vivo studies of a maglev centrifugal left ventricular assist device. , 2001, Artificial organs.

[35]  Akira Chiba,et al.  An analysis of bearingless AC motors , 1994 .

[36]  K. Litwak,et al.  HeartMate III: Pump Design for a Centrifugal LVAD with a Magnetically Levitated Rotor , 2001, ASAIO journal.

[37]  K. Butler,et al.  HeartMate left ventricular assist devices: a multigeneration of implanted blood pumps. , 2001, Artificial organs.

[38]  Daniel Tamez,et al.  Total Heart Replacement with Dual Centrifugal Ventricular Assist Devices , 2005, ASAIO journal.

[39]  Jed Ludlow,et al.  A magnetic suspension theory and its application to the HeartQuest ventricular assist device. , 2002, Artificial organs.

[40]  S Westaby,et al.  Reliable long-term non-pulsatile circulatory support without anticoagulation. , 2001, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[41]  Setsuo Takatani,et al.  Beyond implantable first generation cardiac prostheses for treatment of end-stage cardiac patients with clinical results in a multicenter. , 2002, Annals of thoracic and cardiovascular surgery : official journal of the Association of Thoracic and Cardiovascular Surgeons of Asia.

[42]  S. Takatani,et al.  A New Design for a Compact Centrifugal Blood Pump with a Magnetically Levitated Rotor , 2004, ASAIO journal.

[43]  Natale Barletta,et al.  Principle and Application of a Bearingless Slice Motor , 1997 .