Highly reproducible swept-source, dispersion-encoded full-range biometry and imaging of the mouse eye.

We report a high-speed, dispersion-encoded, full-range (DEFR) swept-source optical coherence tomography system for in vivo ocular imaging and biometry of small animals. The fast DEFR algorithm removes the depth ambiguity, gives access to objects located at the zero delay position, and doubles the sampling depth to 2x5.0 mm (at -101 to -71 dB sensitivity) in a single scan using 2048 samples/depth scan 0.43 nm line width of a light source operating at 1056 nm with 70 nm tuning range. The acquisition speed (frames of 512 depth scans in 18.3 ms) permits precise on-line monitoring during positioning and provides cross-sectional views of the mouse eye. Preliminary studies demonstrate high-throughput, reproducible assessment of multiple biometric features (e.g., day-to-day reproducibility of axial length measurement +/-5.3 microm) that is insensitive to eye motion sufficient for long-term monitoring.

[1]  J. Fujimoto,et al.  Optical Coherence Tomography , 1991, LEOS '92 Conference Proceedings.

[2]  R. Hill,et al.  Analysis of mouse eye development with chimeras and mosaics. , 2004, The International journal of developmental biology.

[3]  N. Eter Molecular imaging in the eye , 2009, British Journal of Ophthalmology.

[4]  Mitchell Vincent Gossman,et al.  Systematic Evaluation of the Mouse Eye: Anatomy, Pathology, and Biomethods , 2004 .

[5]  J. Fujimoto,et al.  Optical coherence tomography: technology and applications , 2002, IEEE/LEOS International Conference on Optical MEMs.

[6]  Frank Schaeffel,et al.  A paraxial schematic eye model for the growing C57BL/6 mouse , 2004, Vision Research.

[7]  Yimin Shen,et al.  Analysis of postnatal eye development in the mouse with high-resolution small animal magnetic resonance imaging. , 2010, Investigative ophthalmology & visual science.

[8]  Michael Pircher,et al.  High sensitive measurement of the human axial eye length in vivo with Fourier domain low coherence interferometry. , 2008, Optics express.

[9]  Manuel Guizar-Sicairos,et al.  Efficient subpixel image registration algorithms. , 2008, Optics letters.

[10]  Eric P.H. Yap,et al.  Two models of experimental myopia in the mouse , 2008, Vision Research.

[11]  Atsushi Morosawa,et al.  Large coherence length swept source for axial length measurement of the eye. , 2009, Applied optics.

[12]  Meixiao Shen,et al.  Biometric measurement of the mouse eye using optical coherence tomography with focal plane advancement , 2008, Vision Research.

[13]  R. Zawadzki,et al.  Numerical dispersion compensation for Partial Coherence Interferometry and Optical Coherence Tomography. , 2001, Optics express.

[14]  Frank Schaeffel,et al.  In vivo biometry in the mouse eye with low coherence interferometry , 2004, Vision Research.

[15]  Y. Yasuno,et al.  Visualization of phase retardation of deep posterior eye by polarization-sensitive swept-source optical coherence tomography with 1-microm probe. , 2009, Optics express.

[16]  G. Ripandelli,et al.  Optical coherence tomography. , 1998, Seminars in ophthalmology.

[17]  W. Drexler,et al.  Dispersion encoded full range frequency domain optical coherence tomography. , 2009, Optics express.

[18]  J. Boatright,et al.  Non-contact measurement of linear external dimensions of the mouse eye , 2010, Journal of Neuroscience Methods.

[19]  Robert W. Williams,et al.  Gene expression in the mouse eye: an online resource for genetics using 103 strains of mice , 2009, Molecular vision.

[20]  F. Stuart Foster,et al.  In Vivo Assessment of Postnatal Murine Ocular Development by Ultrasound Biomicroscopy , 2005, Current eye research.

[21]  Fred P. Seeber,et al.  OP-TEC national center for optics and photonics education and ANSI Z136.5 American National Standard for the safe use of lasers in educational institutions – How they will work together to improve laser safety in educational institutions , 2009 .

[22]  Gerald Matz,et al.  Fast dispersion encoded full range optical coherence tomography for retinal imaging at 800 nm and 1060 nm. , 2010, Optics express.

[23]  M. Angelis,et al.  Variations of eye size parameters among different strains of mice , 2006, Mammalian Genome.