Dose‐ rather than fluence‐averaged LET should be used as a single‐parameter descriptor of proton beam quality for radiochromic film dosimetry

Purpose The dose response of Gafchromic EBT3 films exposed to proton beams depends on the dose, and additionally on the beam quality, which is often quantified with the linear energy transfer (LET) and, hence, also referred to as LET quenching. Fundamentally different methods to determine correction factors for this LET quenching effect have been reported in literature and a new method using the local proton fluence distribution differential in LET is presented. This method was exploited to investigate whether a more practical correction based on the dose‐ or fluence‐averaged LET is feasible in a variety of clinically possible beam arrangements. Methods The relative effectiveness (RE) was characterized within a high LET spread‐out Bragg peak (SOBP) in water made up by the six lowest available energies (62.4–67.5 MeV, configuration “b1”) resulting in one of the highest clinically feasible dose‐averaged LET distributions. Additionally, two beams were measured where a low LET proton beam (252.7 MeV) was superimposed on “b1”, which contributed either 50% of the initial particle fluence or 50% of the dose in the SOBP, referred to as configuration “b2” and “b3,” respectively. The proton LET spectrum was simulated with GATE/Geant4 at all measurement positions. The net optical density change differential in LET was integrated over the local proton spectrum to calculate the net optical density and therefrom the beam quality correction factor. The LET dependence of the film response was accounted for by an LET dependence of one of the three parameters in the calibration function and was determined from inverse optimization using measurement “b1.” This method was then validated on the measurements of “b2” and “b3” and subsequently used to calculate the RE at 900 positions in nine clinically relevant beams. The extrapolated RE set was used to derive a simple linear correction function based on dose‐averaged LET (Ld) and verify the validity in all points of the comprehensive RE set. Results The uncorrected film dose deviated up to 26% from the reference dose, whereas the corrected film dose agreed within 3% in all three beams in water (“b1”, “b2” and “b3”). The LET dependence of the calibration function started to strongly increase around 5 keV/μm and flatten out around 30 keV/μm. All REs calculated from the proton fluence in the nine simulated beams could be approximated with a linear function of dose‐averaged LET (RE = 1.0258−0.0211 μm/keV Ld). However, no functional relationship of RE‐ and fluence‐averaged LET could be found encompassing all beam energies and modulations. Conclusions The film quenching was found to be nonlinear as a function of proton LET as well as of the dose‐averaged LET. However, the linear relation of RE on dose‐averaged LET was a good approximation in all cases. In contrast to dose‐averaged LET, fluence‐averaged LET could not describe the RE when multiple beams were applied.

[1]  D. Georg,et al.  Phantom design and dosimetric characterization for multiple simultaneous cell irradiations with active pencil beam scanning , 2019, Radiation and Environmental Biophysics.

[2]  L. Dewerd,et al.  LET response variability of Gafchromic TM EBT3 film from a 60 Co calibration in clinical proton beam qualities. , 2019, Medical physics.

[3]  L. Grzanka,et al.  THE ROLE OF PARTICLE SPECTRA IN MODELING THE RELATIVE BIOLOGICAL EFFECTIVENESS OF PROTON RADIOTHERAPY BEAMS. , 2019, Radiation protection dosimetry.

[4]  M. Stock,et al.  Evaluation of electromagnetic and nuclear scattering models in GATE/Geant4 for proton therapy , 2019, Medical physics.

[5]  S. E. Anderson,et al.  A linear relationship for the LET-dependence of Gafchromic EBT3 film in spot-scanning proton therapy , 2019, Physics in medicine and biology.

[6]  D. J. Brenner,et al.  LET dependent response of GafChromic films investigated with MeV ion beams , 2018, Physics in medicine and biology.

[7]  L. Grzanka,et al.  MONTE CARLO SIMULATIONS OF SPATIAL LET DISTRIBUTIONS IN CLINICAL PROTON BEAMS , 2018, Radiation protection dosimetry.

[8]  J. Lárraga-Gutiérrez,et al.  Investigation of EBT3 radiochromic film's response to humidity , 2018, Journal of applied clinical medical physics.

[9]  Hugo Palmans,et al.  Characteristic of EBT-XD and EBT3 radiochromic film dosimetry for photon and proton beams , 2018, Physics in medicine and biology.

[10]  Alexander Utz,et al.  The technological basis for adaptive ion beam therapy at MedAustron: Status and outlook. , 2017, Zeitschrift fur medizinische Physik.

[11]  A. Lühr,et al.  Modeling in vivo relative biological effectiveness in particle therapy for clinically relevant endpoints , 2017, Acta oncologica.

[12]  K Parodi,et al.  A phenomenological relative biological effectiveness approach for proton therapy based on an improved description of the mixed radiation field , 2017, Physics in medicine and biology.

[13]  Hugo Palmans,et al.  Beam monitor calibration in scanned light-ion beams. , 2016, Medical Physics (Lancaster).

[14]  Marco Durante,et al.  New Ions for Therapy. , 2015, International journal of particle therapy.

[15]  R. Mohan,et al.  Analysis of the track- and dose-averaged LET and LET spectra in proton therapy using the geant4 Monte Carlo code. , 2015, Medical physics.

[16]  M. Pimpinella,et al.  Calibration of GafChromic EBT3 for absorbed dose measurements in 5 MeV proton beam and (60)Co γ-rays. , 2015, Medical physics.

[17]  A. Carabe,et al.  A critical study of different Monte Carlo scoring methods of dose average linear-energy-transfer maps calculated in voxelized geometries irradiated with clinical proton beams , 2015, Physics in medicine and biology.

[18]  K Parodi,et al.  Investigation of EBT2 and EBT3 films for proton dosimetry in the 4–20 MeV energy range , 2015, Radiation and environmental biophysics.

[19]  B. Jones,et al.  Under-response correction for EBT3 films in the presence of proton spread out Bragg peaks. , 2014, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[20]  Markus Stock,et al.  Radiochromic film dosimetry: considerations on precision and accuracy for EBT2 and EBT3 type films. , 2014, Zeitschrift fur medizinische Physik.

[21]  R. Khan,et al.  Energy response of EBT3 radiochromic films: implications for dosimetry in kilovoltage range , 2014, Journal of applied clinical medical physics.

[22]  R. Mohan,et al.  LET dependence of the response of EBT2 films in proton dosimetry modeled as a bimolecular chemical reaction , 2013, Physics in medicine and biology.

[23]  J. Herault,et al.  Development and validation of radiochromic film dosimetry and Monte Carlo simulation tools for acquisition of absolute, high-spatial resolution longitudinal dose distributions in ocular proton therapy , 2013 .

[24]  M. Durante,et al.  Systematic analysis of RBE and related quantities using a database of cell survival experiments with ion beam irradiation , 2012, Journal of radiation research.

[25]  J J Wilkens,et al.  Comparison of Gafchromic EBT2 and EBT3 films for clinical photon and proton beams. , 2012, Medical physics.

[26]  S. Devic,et al.  EBT2 film as a depth-dose measurement tool for radiotherapy beams over a wide range of energies and modalities. , 2012, Medical physics.

[27]  J. Herault,et al.  Radiochromic EBT2 film dosimetry for low-energy protontherapy. , 2011, Medical physics.

[28]  H Paganetti,et al.  Elevated LET components in clinical proton beams , 2011, Physics in medicine and biology.

[29]  H. Bae,et al.  Dose verification of proton beam therapy using the Gafchromic EBT film , 2011 .

[30]  A. Micke,et al.  Multichannel film dosimetry with nonuniformity correction. , 2011, Medical physics.

[31]  Jan J Wilkens,et al.  Advanced treatment planning methods for efficient radiation therapy with laser accelerated proton and ion beams. , 2010, Medical physics.

[32]  Indra J Das,et al.  Gafchromic EBT film dosimetry in proton beams , 2010, Physics in medicine and biology.

[33]  O. Jäkel,et al.  Study of Gafchromic® EBT film response over a large dose range , 2010, Physics in medicine and biology.

[34]  H. Palmans,et al.  LET dependence of GafChromic films and an ion chamber in low-energy proton dosimetry , 2010, Physics in medicine and biology.

[35]  J. J. Ferrero,et al.  From the limits of the classical model of sensitometric curves to a realistic model based on the percolation theory for GafChromic EBT films. , 2009, Medical physics.

[36]  I. Vitkin,et al.  Temperature and hydration effects on absorbance spectra and radiation sensitivity of a radiochromic medium. , 2008, Medical physics.

[37]  A. Rink Point-based ionizing radiation dosimetry using radiochromic materials and a fibreoptic readout system. , 2008 .

[38]  Uwe Oelfke,et al.  Optimization of radiobiological effects in intensity modulated proton therapy. , 2005, Medical physics.

[39]  G. Kraft,et al.  Experimental investigations of the response of films to heavy-ion irradiation. , 2001, Physics in medicine and biology.

[40]  J. Seuntjens,et al.  Monte Carlo study of electron spectra and dose from backscattered radiation in the vicinity of media interfaces for monoenergetic photons of 50-1250 keV. , 1995, Radiation research.

[41]  L. Papiez,et al.  Radiance and particle fluence. , 1994, Physics in medicine and biology.

[42]  C. Candler Photographic Characteristic of a Monolayer , 1962 .

[43]  R. Khan,et al.  Energy response of EBT3 radiochromic films: implications for dosimetry in kilovoltage range. , 2014, Journal of applied clinical medical physics.

[44]  F. Verhaegen,et al.  Monte Carlo study of fluence perturbation effects on cavity dose response in clinical proton beams. , 1998, Physics in medicine and biology.