Comparison of twelve-lead electrocardiogram using a glove-based recording system with standard methodology.

We tested the clinically relevant diagnostic accuracy of a new electrocardiographic (ECG) recording system incorporating all 10 ECG electrodes in a single-size glove worn on the patient's left arm and placed on the chest. The PhysioGlove (PG) was designed to allow fast, reproducible, electrode placement with only minimal training. The American College of Cardiology/American Heart Association ECG recording guidelines and others have repeatedly highlighted the unacceptable progressive deterioration in ECG accuracy mainly resulting from a performer's lack of proficiency and diligence, leading to frequent electrode misplacement. We studied 428 consenting adult patients with a broad spectrum of anthropomorphic characteristics and ECG and cardiovascular pathologic entities. The chest girth was measured to ascertain the single-size PG clinical diagnostic accuracy in ≥90% of this patient population. For each patient, a PG and standard-cable electrocardiogram were consecutively recorded and interpreted by experienced electrocardiographers. The study included 3 phases: phase 1, run-in (n = 120); phase 2, comparative diagnostic accuracy (n = 208); and phase 3, randomized, blinded, diagnostic accuracy (n = 100). Of the entire study population (n = 428), 92% fit the chest girth range of 85 to 118 cm (34 to 47 in.), representing the reference standard clinical diagnostic PG chest girth range. The phase 2 PG diagnostic accuracy was 91.3% for entire chest girth range and 95.7% for the 89.4% of patients with a chest girth within the reference range. The mean PG diagnostic accuracy in phase 3 was 93% (95% confidence interval 89% to 95%). In conclusion, compared with standard-cable electrocardiograms, the PG demonstrated excellent diagnostic accuracy (93% to 95.7%) in ≥90% of a typical western adult patient population. The PG's ease of use and minimal training requirements offer a promising tool to markedly improve ECG clinical diagnostic accuracy in most adult western patients.

[1]  S. Salerno,et al.  Training and Competency Evaluation for Interpretation of 12-Lead Electrocardiograms: Recommendations from the American College of Physicians* , 2003, Annals of Internal Medicine.

[2]  P W Macfarlane,et al.  Methods for Improving the Repeatability of Automated ECG Analysis , 1995, Methods of Information in Medicine.

[3]  Geoffrey R. Norman,et al.  Impact of a clinical scenario on accuracy of electrocardiogram interpretation , 1999, Journal of General Internal Medicine.

[4]  Roger Fisher,et al.  Pre-hospital electrocardiography by emergency medical personnel: effects on scene and transport times for chest pain and ST-segment elevation myocardial infarction patients. , 2012, Journal of the American College of Cardiology.

[5]  J. Ornato,et al.  Development of systems of care for ST-elevation myocardial infarction patients: the emergency medical services and emergency department perspective. , 2007, Circulation.

[6]  R. Popp,et al.  Clinical competence in adult echocardiography. A statement for physicians from the ACP/ACC/AHA Task Force on Clinical Privileges in Cardiology. , 1990, Circulation.

[7]  C. Fisch Clinical competence in electrocardiography. A statement for physicians from the ACP/ACC/AHA Task Force on Clinical Privileges in Cardiology. , 1995, Circulation.

[8]  P Kligfield,et al.  Variability of precordial electrode placement during routine electrocardiography. , 1996, Journal of electrocardiology.

[9]  E. W. Hancock,et al.  Recommendations for the standardization and interpretation of the electrocardiogram: part II: electrocardiography diagnostic statement list a scientific statement from the American Heart Association Electrocardiography and Arrhythmias Committee, Council on Clinical Cardiology; the American College o , 2007, Journal of the American College of Cardiology.

[10]  Frank Bogun,et al.  Accuracy of electrocardiogram interpretation by cardiologists in the setting of incorrect computer analysis. , 2006, Journal of electrocardiology.

[11]  T. Suzuki,et al.  Comparative accuracy of automated computer analysis versus physicans in training in the interpretation of electrocardiograms. , 1999, Journal of medicine.

[12]  D. Francis,et al.  Accuracy in ECG lead placement among technicians, nurses, general physicians and cardiologists , 2007, International journal of clinical practice.

[13]  Jan A. Kors,et al.  Employment of Intra-Individual Variability to Improve Computerized ECG Interpretation , 2001, MedInfo.

[14]  S. Salerno,et al.  Competency in Interpretation of 12-Lead Electrocardiograms: A Summary and Appraisal of Published Evidence , 2003, Annals of Internal Medicine.

[15]  E. W. Hancock,et al.  Recommendations for the standardization and interpretation of the electrocardiogram: part II: Electrocardiography diagnostic statement list: a scientific statement from the American Heart Association Electrocardiography and Arrhythmias Committee, Council on Clinical Cardiology; the American College , 2007, Circulation.

[16]  E. W. Hancock,et al.  AHA/ACCF/HRS recommendations for the standardization and interpretation of the electrocardiogram: part III: intraventricular conduction disturbances: a scientific statement from the American Heart Association Electrocardiography and Arrhythmias Committee, Council on Clinical Cardiology; the American , 2009, Journal of the American College of Cardiology.

[17]  Anna Holdgate,et al.  Accuracy of ECG electrode placement by emergency department clinicians , 2007, Emergency medicine Australasia : EMA.

[18]  A. Hoes,et al.  Diagnostic interpretation of electrocardiograms in population-based research: computer program research physicians, or cardiologists? , 1997, Journal of clinical epidemiology.

[19]  H V Pipberger,et al.  The impact of an ECG computer analysis program on the cardiologist's interpretation. A cooperative study. , 1983, Journal of electrocardiology.

[20]  Donald P. Connelly,et al.  The Effects of Computer-assisted Electrocardiographic Interpretation on Physicians' Diagnostic Decisions , 1995, Medical decision making : an international journal of the Society for Medical Decision Making.

[21]  P. Dunn,et al.  The lack of effect of clinical information on electrocardiographic diagnosis of acute myocardial infarction. , 1990, Archives of Internal Medicine.

[22]  C Brohet,et al.  Effect of combining electrocardiographic interpretation results on diagnostic accuracy. , 1988, European heart journal.

[23]  R. Tibshirani,et al.  An introduction to the bootstrap , 1993 .

[24]  C. Tracy,et al.  ACC/AHA clinical competence statement on electrocardiography and ambulatory electrocardiography: A report of the ACC/AHA/ACP-ASIM task force on clinical competence (ACC/AHA Committee to develop a clinical competence statement on electrocardiography and ambulatory electrocardiography) endorsed by the , 2001, Circulation.

[25]  J A Kors,et al.  Effect of electrode positioning on ECG interpretation by computer. , 1997, Journal of electrocardiology.