Median prior constrained TV algorithm for sparse view low-dose CT reconstruction

It is known that lowering the X-ray tube current (mAs) or tube voltage (kVp) and simultaneously reducing the total number of X-ray views (sparse view) is an effective means to achieve low-dose in computed tomography (CT) scan. However, the associated image quality by the conventional filtered back-projection (FBP) usually degrades due to the excessive quantum noise. Although sparse-view CT reconstruction algorithm via total variation (TV), in the scanning protocol of reducing X-ray tube current, has been demonstrated to be able to result in significant radiation dose reduction while maintain image quality, noticeable patchy artifacts still exist in reconstructed images. In this study, to address the problem of patchy artifacts, we proposed a median prior constrained TV regularization to retain the image quality by introducing an auxiliary vector m in register with the object. Specifically, the approximate action of m is to draw, in each iteration, an object voxel toward its own local median, aiming to improve low-dose image quality with sparse-view projection measurements. Subsequently, an alternating optimization algorithm is adopted to optimize the associative objective function. We refer to the median prior constrained TV regularization as "TV_MP" for simplicity. Experimental results on digital phantoms and clinical phantom demonstrated that the proposed TV_MP with appropriate control parameters can not only ensure a higher signal to noise ratio (SNR) of the reconstructed image, but also its resolution compared with the original TV method.

[1]  Guang-Hong Chen,et al.  Dose reduction using prior image constrained compressed sensing (DR-PICCS) , 2011, Medical Imaging.

[2]  Guang-Hong Chen,et al.  Characterization of statistical prior image constrained compressed sensing (PICCS): II. Application to dose reduction. , 2013, Medical physics.

[3]  Guang-Hong Chen,et al.  Extraction of tumor motion trajectories using PICCS-4DCBCT: a validation study. , 2011, Medical physics.

[4]  Xiaochuan Pan,et al.  Enhanced imaging of microcalcifications in digital breast tomosynthesis through improved image-reconstruction algorithms. , 2009, Medical physics.

[5]  E. Sidky,et al.  Accurate image reconstruction from few-views and limited-angle data in divergent-beam CT , 2009, 0904.4495.

[6]  Emmanuel J. Candès,et al.  Robust uncertainty principles: exact signal reconstruction from highly incomplete frequency information , 2004, IEEE Transactions on Information Theory.

[7]  Mike E. Davies,et al.  Gradient Pursuits , 2008, IEEE Transactions on Signal Processing.

[8]  Yuanke Zhang,et al.  Statistical Sinogram Smoothing for Low-Dose CT With Segmentation-Based Adaptive Filtering , 2010, IEEE Transactions on Nuclear Science.

[9]  L. Shepp,et al.  A Statistical Model for Positron Emission Tomography , 1985 .

[10]  T G Turkington,et al.  Introduction to PET instrumentation. , 2001, Journal of nuclear medicine technology.

[11]  Jing Wang Noise reduction for low-dose x-ray computed tomography , 2006 .

[12]  Zhengrong Liang,et al.  Adaptive-weighted total variation minimization for sparse data toward low-dose x-ray computed tomography image reconstruction , 2012, Physics in medicine and biology.

[13]  Jean-Baptiste Thibault,et al.  A three-dimensional statistical approach to improved image quality for multislice helical CT. , 2007, Medical physics.

[14]  Lei Zhang,et al.  Low-Dose X-ray CT Reconstruction via Dictionary Learning , 2012, IEEE Transactions on Medical Imaging.

[15]  Jie Tang,et al.  Time-resolved cardiac interventional cone-beam CT reconstruction from fully truncated projections using the prior image constrained compressed sensing (PICCS) algorithm , 2012, Physics in medicine and biology.

[16]  Zhang Jun Noise analysis and noise reduction for low-dose CT sinogram , 2010 .

[17]  Jie Tang,et al.  Temporal resolution improvement in cardiac CT using PICCS (TRI-PICCS): performance studies. , 2010, Medical physics.

[18]  Zhengrong Liang,et al.  Noise reduction for low-dose single-slice Helical CT sinogram , 2004 .

[19]  Z. Liang,et al.  Noise reduction for low-dose single-slice Helical CT sinogram , 2006, IEEE Symposium Conference Record Nuclear Science 2004..

[20]  Anand Rangarajan,et al.  A new convex edge-preserving median prior with applications to tomography , 2003, IEEE Transactions on Medical Imaging.

[21]  Jiayu Song,et al.  Sparseness prior based iterative image reconstruction for retrospectively gated cardiac micro-CT. , 2007, Medical physics.

[22]  Hengyong Yu,et al.  Compressed sensing based interior tomography , 2009, Physics in medicine and biology.

[23]  E. Veklerov,et al.  MLE reconstruction of a brain phantom using a Monte Carlo transition matrix and a statistical stopping rule , 1988 .

[24]  Jie Tang,et al.  Performance comparison between total variation (TV)-based compressed sensing and statistical iterative reconstruction algorithms , 2009, Physics in medicine and biology.

[25]  E. Sidky,et al.  Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization , 2008, Physics in medicine and biology.

[26]  Eric A. Hoffman,et al.  Statistical Interior Tomography , 2011, IEEE Transactions on Medical Imaging.

[27]  Zhiguo Gui,et al.  A statistical iteration approach with energy minimization to sinogram noise reduction for low-dose X-ray CT , 2012 .

[28]  Jie Tang,et al.  Prior image constrained compressed sensing (PICCS): a method to accurately reconstruct dynamic CT images from highly undersampled projection data sets. , 2008, Medical physics.

[29]  J Trzasko,et al.  Nonconvex prior image constrained compressed sensing (NCPICCS): theory and simulations on perfusion CT. , 2011, Medical physics.

[30]  Gaohang Yu,et al.  Sparse-view x-ray CT reconstruction via total generalized variation regularization , 2014, Physics in medicine and biology.