Possibilities and limitations of fast temperature programming as a route towards fast GC

One possible way to speed up a gas chromatographic analysis is the application of fast temperature programming by using resistive heating techniques. With this heating technique programming rates up to 20° per second can be reached. A relative standard deviation of retention times better than 0.2% is obtained. Using fast temperature programming the analysis-times of a mineral oil sample, an industrial oligomer sample, and toxic compounds in diesel fuel have been reduced 5 to 20 times, compared to a standard temperature programmed analysis. In most cases resistive heating cannot be applied to reduce the analysis time of a complex sample. The use of fast temperature programming is preferable to the use of short columns and columns operated at above-optimum carrier gas velocities.

[1]  L. Blumberg Theory of fast capillary gas chromatography. Part 1: Column efficiency , 1997 .

[2]  V. Jain,et al.  Fast Temperature Programming on Fused-Silica Open-Tubular Capillary Columns by Direct Resistive Heating , 1995 .

[3]  C. Cramers,et al.  High‐speed GC/MS using narrow‐bore columns and ion trap detection , 1993 .

[4]  Ja Jacques Rijks,et al.  Increased speed of analysis in isothermal and temperature-programmed capillary gas chromatography by reduction of the column inner diameter , 1982 .

[5]  R. Yost,et al.  Compact gas chromatograph probe for gas chromatography/mass spectrometry utilizing resistively heated aluminum-clad capillary columns , 1989 .

[6]  C. Cramers,et al.  Increased speed of analysis in directly coupled gas chromatography-mass spectrometry systems : capillary columns at sub-atmospheric outlet pressures , 1981 .

[7]  E. Overton,et al.  Novel Column Heater for Fast Capillary Gas Chromatography , 1996 .

[8]  C. Cramers,et al.  Optimum performance of capillary GC columns as a function of tube diameter and film thickness under various operating conditions. Computer program for calculation of H‐ū curves and minimum analysis times , 1985 .

[9]  H. Poppe,et al.  Improvement of speed of separation in packed column gas chromatography , 1982 .

[10]  C. Cramers,et al.  TURBULENT FLOW IN CAPILLARY GAS CHROMATOGRAPHY , 1989 .

[11]  R. Tijssen Liquid Chromatography in Helically Coiled Open Tubular Columns , 1978 .

[12]  R. Tijssen,et al.  Theoretical aspects and practical potentials of rapid gas analysis in capillary gas chromatography , 1987 .

[13]  M. V. Russo Fast headspace analysis with short microcapillary columns , 1995 .

[14]  P. Leclercq Optimum Performance of Capillary GC Columns as a Function of Column Diameter and Film Thickness under Various Operating Conditions: Part II: Computer Program Extensions for n-Alkane Solutes and Polydimethylsiloxane Phases') , 1992 .