Brachytherapy dosimetry parameters calculated for a new 103Pd source.

A new brachytherapy source having 103Pd adsorbed onto silver beads has been designed. The dose distributions of this source have been characterized using version 5 of the MCNP Monte Carlo radiation transport code available from Oak Ridge National Laboratory. These results are presented in terms of the updated AAPM Task Group No. 43 (TG-43U1) formalism, dosimetry parameters, and recommended calculation methodology.

[1]  Zuofeng Li,et al.  Monte Carlo calculations of dosimetry parameters of the urocor prostaseed 125I source. , 2002, Medical physics.

[2]  Lellery Storm,et al.  Photon cross sections from 1 keV to 100 MeV for elements Z=1 to Z=100 , 1970 .

[3]  J F Williamson,et al.  Comparison of measured and calculated dose rates in water near I-125 and Ir-192 seeds. , 1991, Medical physics.

[4]  L. Anderson,et al.  Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43 , 1995 .

[5]  D Granero,et al.  Phantom size in brachytherapy source dosimetric studies. , 2004, Medical physics.

[6]  A. Meigooni,et al.  Dosimetric characteristics of the InterSource103 palladium brachytherapy source. , 2000, Medical physics.

[7]  J. Williamson,et al.  Monte Carlo-aided dosimetry of the Symmetra model I25.S06 125I, interstitial brachytherapy seed. , 2000, Medical physics.

[8]  Kirsten Boedeker,et al.  An analysis of MCNP cross-sections and tally methods for low-energy photon emitters. , 2002, Physics in medicine and biology.

[9]  A. Meigooni,et al.  Dosimetric characteristics of the bests double-wall 103Pd brachytherapy source. , 2001, Medical physics.

[10]  R Nath,et al.  Dosimetric prerequisites for routine clinical use of new low energy photon interstitial brachytherapy sources. Recommendations of the American Association of Physicists in Medicine Radiation Therapy Committee. Ad Hoc Subcommittee of the Radiation Therapy Committee. , 1998, Medical physics.

[11]  J. Williamson,et al.  Monte Carlo modeling of the transverse-axis dose distribution of the model 200 103Pd interstitial brachytherapy source. , 2000, Medical physics.

[12]  S. Seltzer,et al.  Evaluation of the new cesium-131 seed for use in low-energy x-ray brachytherapy. , 2004, Medical physics.

[13]  B. Thomadsen,et al.  Measurements of the dosimetric constants for a new 103Pd brachytherapy source. , 2002, Brachytherapy.

[14]  J. Williamson Dosimetric characteristics of the DRAXIMAGE model LS-1 1-125 interstitial brachytherapy source design: a Monte Carlo investigation. , 2002, Medical physics.

[15]  Z. Chen,et al.  Dose rate constant of a cesium-131 interstitial brachytherapy seed measured by thermoluminescent dosimetry and gamma-ray spectrometry. , 2005, Medical physics.

[16]  M. Rivard A discretized approach to determining TG-43 brachytherapy dosimetry parameters: case study using Monte Carlo calculations for the MED3633 103Pd source. , 2001, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[17]  Mark J. Rivard,et al.  A technical evaluation of the Nucletron FIRST system: Conformance of a remote afterloading brachytherapy seed implantation system to manufacturer specifications and AAPM Task Group report recommendations , 2005, Journal of applied clinical medical physics.

[18]  N. Yue,et al.  Experimental determination of dosimetric characterization of a newly designed encapsulated interstitial brachytherapy source of 103Pd-model Pd-1. , 2002, Medical physics.

[19]  S M Seltzer,et al.  Calculation of photon mass energy-transfer and mass energy-absorption coefficients. , 1993, Radiation research.

[20]  J. Williamson,et al.  Monte Carlo-aided dosimetry of the Source Tech Medical Model STM1251 I-125 interstitial brachytherapy source. , 2001, Medical physics.

[21]  M. Rivard Monte Carlo calculations of AAPM Task Group Report No. 43 dosimetry parameters for the MED3631-A/M125I source. , 2001, Medical physics.

[22]  P. Scalliet,et al.  Dosimetric study of a new palladium seed. , 2002, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[23]  J. Williamson,et al.  Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations. , 2004 .

[24]  R. Nath,et al.  A comparison of solid phantoms with water for dosimetry of 125I brachytherapy sources. , 1988, Medical physics.

[25]  M. Rivard Dosimetry for 252Cf neutron emitting brachytherapy sources: protocol, measurements, and calculations. , 1999, Medical physics.

[26]  D. Duggan,et al.  Improved radial dose function estimation using current version MCNP Monte-Carlo simulation: Model 6711 and ISC3500 125I brachytherapy sources. , 2004, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.