Evaluation of Maintained Load Test (MLT) and Pile Driving Analyzer (PDA) in Measuring Bearing Capacity of Driven Reinforced Concrete Piles

Results of several full scale RC (reinforced concrete) pile load tests were studied and analyzed to create a comparison between the MLT (maintained load test) and PDA (pile driving analyzer) methods. The ultimate pile capacities derived from analysis of PDA were consistently higher than results from the MLT. A coefficient of 0.9 or a 10% reduction is suggested to be applied to values derived from PDA. It is also observed that the longer the time interval, the greater the shaft friction contribution is towards the pile capacity.

[1]  Woojin Lee,et al.  Real-time monitoring of SPT donut hammer motion and SPT energy transfer ratio using digital line-scan camera and pile driving analyzer , 2014 .

[2]  Aravinda Ramakrishna,et al.  Reliability of Pile Driving Analyzer for Determination of Axial Capacity of Large-Diameter Cylindrical Pile , 2010 .

[3]  Paul J Bullock Advantages of Dynamic Pile Testing , 2012 .

[4]  M. Sakr Comparison between high strain dynamic and static load tests of helical piles in cohesive soils , 2013 .

[5]  Camilo Alvarez,et al.  Dynamic Pile Analysis Using CAPWAP and Multiple Sensors , 2006 .

[6]  Joseph E. Bowles,et al.  Foundation analysis and design , 1968 .

[7]  Zou Dong-feng Behaviors of bearing capacity of ultra-long bored piles , 2013 .

[8]  Garland Likins,et al.  Analysis of Post-Installation Dynamic Load Test Data for Capacity Evaluation of Deep Foundations , 2008 .

[9]  Spg Madabhushi,et al.  Axial load transfer in liquefiable soils for free-standing piles , 2013 .

[10]  Kathleen A. Issen,et al.  Compaction localization in the Earth and the laboratory: state of the research and research directions , 2007 .

[11]  Sri Sritharan,et al.  Pile Setup in Cohesive Soil. I: Experimental Investigation , 2013 .

[12]  Garland Likins,et al.  Dynamic Determination of Pile Capacity , 1985 .

[13]  Garland Likins,et al.  CORRELATION OF CAPWAP WITH STATIC LOAD TESTS , 2004 .

[14]  Donald P. Coduto,et al.  Foundation Design: Principles and Practices , 2000 .

[15]  G. Likins What constitutes a good PDA test ? , .

[16]  Virgil A. Baker,et al.  Pile Foundation Design Using Pile Driving Analyzer , 1984 .

[17]  Kazem Fakharian A Case Study On the Application of Pile Driving Analyzer (PDA) And CAPWAP Analysis to Bearing Capacity of Piles , 2000 .

[18]  Frank Rausche,et al.  PILE LOAD TEST BY IMPACT DRIVING , 1970 .