MRI-Based Evaluation of the Vaginal Cuff in Brachytherapy Planning: Are We Missing the Target?

PURPOSE Although recurrences and toxicity occur after vaginal cuff (VC) brachytherapy, little is known about dosimetry due to the inability to clearly visualize the VC on computed tomography (CT). T2-weighted (T2W) magnetic resonance imaging (MRI) is superior to CT in this setting, and we hypothesized that it could provide previously unascertainable dosimetric information. METHODS AND MATERIALS In a cohort of 32 patients who underwent cylinder-based brachytherapy for endometrial cancer with available MR simulation images, the VC was retrospectively contoured on T2W images, and cases were replanned to treat the upper VC to a dose of 7 Gy/fraction prescribed to 5 mm. Relevant dose-volume parameters for the VC were calculated. RESULTS T2W MRI identified significant underdosing not observed on CT or T1-weighted imaging. Over two-thirds (69%) of patients had at least 1 cm(3) of VC that received less than 75% of the prescription dose and half (50%) of patients had a least 1 cm(3) of VC that received less than 50% of the prescription dose. The mean minimum point dose to the VC was 2.4 Gy, or 34% of the intended prescription dose (range: 0.53-6.4 Gy). CONCLUSIONS We identified previously unreported VC underdosing in over two-thirds of our patients, with most of these patients having volumes of undistended VC that received less than half of the prescription dose. The maximum dimension was along the craniocaudal axis in some patients or left-right/anterior-posterior axis in others, suggesting that suture material may be restricting access to the vaginal apex and that alternative applicators may be needed when the diameter of the apex is larger than the introitus. Additional follow-up will be needed to determine whether underdosing is associated with isolated VC failure or whether low failure rates across the cohort suggest that some patients are being exposed to excessive dose and unnecessary risk of toxicity.

[1]  H. Kauczor,et al.  Imaging of female pelvic malignancies regarding MRI, CT, and PET/CT , 2011, Strahlentherapie und Onkologie.

[2]  S. Jolly,et al.  Vaginal brachytherapy alone: an alternative to adjuvant whole pelvis radiation for early stage endometrial cancer. , 2005, Gynecologic oncology.

[3]  C. Sirlin,et al.  MRI of the female pelvis using vaginal gel. , 2005, AJR. American journal of roentgenology.

[4]  Rémi,et al.  Endometrium FIFTEEN-YEAR RADIOTHERAPY OUTCOMES OF THE RANDOMIZED PORTEC-1 TRIAL FOR ENDOMETRIAL CARCINOMA , 2011 .

[5]  H. Kauczor,et al.  Imaging of female pelvic malignancies regarding MRI, CT, and PET/CT , 2011, Strahlentherapie und Onkologie.

[6]  M. Siedhoff,et al.  Decreased incidence of vaginal cuff dehiscence after laparoscopic closure with bidirectional barbed suture. , 2011, Journal of minimally invasive gynecology.

[7]  Antonio Farina,et al.  Vaginal cuff dehiscence after hysterectomy: a multicenter retrospective study. , 2011, European journal of obstetrics, gynecology, and reproductive biology.

[8]  P. Grigsby,et al.  Dosimetric effects of air pockets around high-dose rate brachytherapy vaginal cylinders. , 2010, International journal of radiation oncology, biology, physics.

[9]  H. Putter,et al.  Vaginal brachytherapy versus pelvic external beam radiotherapy for patients with endometrial cancer of high-intermediate risk (PORTEC-2): an open-label, non-inferiority, randomised trial , 2010, The Lancet.

[10]  S. Davidson,et al.  Magnetic resonance imaging of primary vaginal carcinoma. , 2007, Clinical radiology.

[11]  J. Rownd,et al.  American Brachytherapy Society consensus guidelines for adjuvant vaginal cuff brachytherapy after hysterectomy. , 2012, Brachytherapy.

[12]  M. Maiman,et al.  A phase III trial of surgery with or without adjunctive external pelvic radiation therapy in intermediate risk endometrial adenocarcinoma: a Gynecologic Oncology Group study. , 2004, Gynecologic oncology.

[13]  Harry Easton,et al.  Customized vaginal vault brachytherapy with computed tomography imaging-derived applicator prototyping. , 2015, Brachytherapy.

[14]  J. Lee,et al.  MR appearance of the normal and abnormal vagina after hysterectomy. , 1992, AJR. American journal of roentgenology.

[15]  J. Adam M. Cunha,et al.  Evaluation of PC-ISO for customized, 3D printed, gynecologic 192Ir HDR brachytherapy applicators. , 2015, Journal of applied clinical medical physics.

[16]  H. Putter,et al.  Long-term impact of endometrial cancer diagnosis and treatment on health-related quality of life and cancer survivorship , 2022 .

[17]  Hye-Chun Hur,et al.  Incidence and patient characteristics of vaginal cuff dehiscence after different modes of hysterectomies. , 2007, Journal of minimally invasive gynecology.

[18]  Christian Kirisits,et al.  Recommendations from Gynaecological (GYN) GEC-ESTRO Working Group (I): concepts and terms in 3D image based 3D treatment planning in cervix cancer brachytherapy with emphasis on MRI assessment of GTV and CTV. , 2005, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[19]  S. Jolly,et al.  Single or multi-channel vaginal cuff high-dose-rate brachytherapy: Is replanning necessary prior to each fraction? , 2014, Practical radiation oncology.

[20]  H. Putter,et al.  Five-year quality of life of endometrial cancer patients treated in the randomised Post Operative Radiation Therapy in Endometrial Cancer (PORTEC-2) trial and comparison with norm data. , 2012, European journal of cancer.

[21]  Ken Goldberg,et al.  Evaluation of PC‐ISO for customized, 3D printed, gynecologic 192Ir HDR brachytherapy applicators , 2015, Journal of applied clinical medical physics.

[22]  A. Viswanathan,et al.  A novel low dose fractionation regimen for adjuvant vaginal brachytherapy in early stage endometrioid endometrial cancer. , 2012, Gynecologic oncology.

[23]  B. Sorbe,et al.  Intravaginal high-dose-rate brachytherapy for stage I endometrial cancer: a randomized study of two dose-per-fraction levels. , 2005, International journal of radiation oncology, biology, physics.