Ion-selective electrodes using multi-walled carbon nanotubes as ion-to-electron transducers for the detection of perchlorate.

A solid contact ion-selective electrode using for the first time multi-walled carbon nanotubes (MWCNT) for the transducer material was developed for detecting perchlorate in water. To demonstrate the excellent ion-to electron transducer ability of the MWCNTs, a 15 microm thick layer of carboxylated MWCNT was deposited between an acrylic membrane selective to perchlorate ions and a glassy carbon rod used as the substrate and electrical conductor. The electrodes showed a Nernstian response of 57 mV decade(-1) (standard deviation of 3 mV decade(-1) over time and different electrodes) across a wide linear range of 10(-6) to 10(-2) M. The limit of detection was 10(-7.4) M of perchlorate. The response time was less than 10 s for activities higher than 10(-6) M and the intermediate-term potential stability shows a small drift of 0.22 mV h(-1) recorded over 5 hours. The electrode displays a selectivity comparable to liquid-contacted ISEs containing the same membrane.

[1]  F. Rius,et al.  Transduction mechanism of carbon nanotubes in solid-contact ion-selective electrodes. , 2009, Analytical chemistry.

[2]  M. Fouskaki,et al.  Fullerene-based electrochemical buffer layer for ion-selective electrodes. , 2008, The Analyst.

[3]  F. Rius,et al.  Ion-selective electrodes using carbon nanotubes as ion-to-electron transducers. , 2008, Analytical chemistry.

[4]  P. Dasgupta,et al.  Dicationic ion-pairing agents for the mass spectrometric determination of perchlorate. , 2007, Analytical chemistry.

[5]  J. D. Lamb,et al.  Determination of perchlorate in drinking water by ion chromatography using macrocycle-based concentration and separation methods. , 2006, Journal of chromatography. A.

[6]  P. Dasgupta,et al.  Matrix interference free determination of perchlorate in urine by ion association-ion chromatography-mass spectrometry. , 2006, Analytica chimica acta.

[7]  Joseph Wang,et al.  Electrochemical biosensors: towards point-of-care cancer diagnostics. , 2006, Biosensors & bioelectronics.

[8]  H. Mousavi,et al.  Extraction Spectrophotometric Determination of Trace Amounts of Perchlorate Based on Ion-Pair Formation with Thionine , 2005 .

[9]  Ernö Pretsch,et al.  Solid-contact polymeric membrane electrodes with detection limits in the subnanomolar range , 2004 .

[10]  J. Ortuño,et al.  Flow-Through Bulk Optode for the Spectrophotometric Determination of Perchlorate , 2003 .

[11]  Hongjie Dai,et al.  Carbon nanotubes: synthesis, integration, and properties. , 2002, Accounts of chemical research.

[12]  P. Avouris,et al.  Engineering Carbon Nanotubes and Nanotube Circuits Using Electrical Breakdown , 2001, Science.

[13]  N. D. de Rooij,et al.  Potential Drifts of Solid‐Contacted Ion‐Selective Electrodes Due to Zero‐Current Ion Fluxes Through the Sensor Membrane , 2000 .

[14]  J. Ortuño,et al.  Perchlorate-selective polymeric membrane electrode based on a gold(I) complex: application to water and urine analysis , 2000 .

[15]  P. Bühlmann,et al.  Selectivity of potentiometric ion sensors. , 2000, Analytical chemistry.

[16]  P. Parilla,et al.  A Simple and Complete Purification of Single‐Walled Carbon Nanotube Materials , 1999 .

[17]  Arabinda Das,et al.  Indirect determination of perchlorate by atomic absorption spectrometry , 1992 .

[18]  Róbert E. Gyurcsányi,et al.  Quality control criteria for solid-contact, solvent polymeric membrane ion-selective electrodes , 2009 .

[19]  Andreas Stein,et al.  Subnanomolar detection limit application of ion-selective electrodes with three-dimensionally ordered macroporous (3DOM) carbon solid contacts , 2009, Journal of solid state electrochemistry : current research and development in science and technology.

[20]  E. Pretsch The new wave of ion-selective electrodes , 2007 .

[21]  Ziqiang Zhu,et al.  Fabrication and Characterization of Potassium Ion-Selective Electrode Based on Porous Silicon , 2007, IEEE Sensors Journal.

[22]  E. Hall,et al.  Producing "self-plasticizing" ion-selective membranes. , 2000, Analytical chemistry.

[23]  P. C. Meier Two-parameter debye-hückel approximation for the evaluation of mean activity coefficients of 109 electrolytes , 1982 .