A simple methodology for characterization of germanium coaxial detectors by using Monte Carlo simulation and evolutionary algorithms.
暂无分享,去创建一个
J. G. Rubiano | J G Guerra | J G Rubiano | G Winter | A G Guerra | H Alonso | M A Arnedo | A Tejera | J M Gil | R Rodríguez | P Martel | J P Bolivar | J. Bolívar | A. Tejera | G. Winter | R. Rodríguez | J. Gil | P. Martel | H. Alonso | M. A. Arnedo | J. G. Guerra | A. G. Guerra | J. P. Bolívar | Antonio González Guerra | Rafael Rodríguez
[1] César Marques Salgado,et al. Determination of HPGe detector response using MCNP5 for 20-150 keV X-rays. , 2006, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.
[2] Z. Molnár,et al. Monte Carlo determination of full energy peak efficiency for a HPGe detector. , 2001, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.
[3] L. Szentmiklósi,et al. Characterization of HPGe gamma spectrometers by geant4 Monte Carlo simulations , 2014, Journal of Radioanalytical and Nuclear Chemistry.
[4] A. Jakobi,et al. Uncertainty of gamma-ray spectrometry measurement of environmental samples due to uncertainties in matrix composition, density and sample geometry. , 2014, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.
[5] H. Heijnis,et al. The determination of the efficiency of a Compton suppressed HPGe detector using Monte Carlo simulations. , 2012, Journal of environmental radioactivity.
[6] Maximising the sensitivity of a γ spectrometer for low-energy, low-activity radionuclides using Monte Carlo simulations. , 2014, Journal of environmental radioactivity.
[7] Arthur C. Sanderson,et al. Adaptive Differential Evolution: A Robust Approach to Multimodal Problem Optimization , 2009 .
[8] A. M. Arogunjo,et al. Rates of intestinal absorption of molybdenum in humans. , 2006, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.
[9] J. Hardy,et al. Precise efficiency calibration of an HPGe detector up to 3.5 MeV, with measurements and Monte Carlo calculations. , 2004, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.
[10] K. Debertin,et al. Gamma- and X-Ray Spectrometry with Semiconductor Detectors , 1988 .
[11] A. Plamboeck,et al. Evaluation of Monte Carlo-based calibrations of HPGe detectors for in situ gamma-ray spectrometry. , 2009, Journal of environmental radioactivity.
[12] M. Maučec,et al. Monte Carlo uncertainty analysis of germanium detector response to γ-rays with energies below 1 MeV , 2005 .
[13] F. Bronson. Validation of the accuracy of the LabSOCS software for mathematical efficiency calibration of Ge detectors for typical laboratory samples , 2003 .
[14] E. Baussan,et al. Simulation approach to coincidence summing in γ-ray spectrometry. , 2012, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.
[15] Saed Dababneh,et al. Application of Geant4 in routine close geometry gamma spectroscopy for environmental samples. , 2014, Journal of environmental radioactivity.
[16] J. F. Briesmeister. MCNP-A General Monte Carlo N-Particle Transport Code , 1993 .
[17] P. N. Suganthan,et al. Differential Evolution: A Survey of the State-of-the-Art , 2011, IEEE Transactions on Evolutionary Computation.
[18] N. C. Díaz,et al. DETEFF: An improved Monte Carlo computer program for evaluating the efficiency in coaxial gamma-ray detectors , 2008 .
[19] D. Todorovic,et al. Calculation of HPGe efficiency for environmental samples: comparison of EFFTRAN and GEANT4 , 2014 .
[20] Peter D. Rostron,et al. Optimising in situ gamma measurements to identify the presence of radioactive particles in land areas. , 2014, Journal of environmental radioactivity.
[21] J. Pérez‐Moreno,et al. A comprehensive calibration method of Ge detectors for low-level gamma-spectrometry measurements , 2002 .
[22] Feng Wang,et al. Optimisation design of cylindrical containers for improving the detection efficiency of a high-purity germanium detector using the LabSOCS , 2013, Journal of Radioanalytical and Nuclear Chemistry.
[23] U. Sansone,et al. The IAEA's 'ALMERA Network' proficiency test on the determination of gamma-emitting radionuclides: a test of results comparability. , 2008, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.
[24] J. Sempau,et al. Experimental benchmarks of the Monte Carlo code penelope , 2003 .
[25] Girard,et al. Monte Carlo calculation of the efficiency calibration curve and coincidence-summing corrections in low-level gamma-ray spectrometry using well-type HPGe detectors , 2000, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.
[26] M. F. Stroosnijder,et al. Reliability of two calculation codes for efficiency calibrations of HPGe detectors. , 2002, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.
[27] L. Johansson,et al. A detailed investigation of HPGe detector response for improved Monte Carlo efficiency calculations , 2008 .
[28] N. Q. Huy,et al. Study on the increase of inactive germanium layer in a high-purity germanium detector after a long time operation applying MCNP code , 2007 .
[29] Rafael García-Tenorio,et al. GEANT4 code for simulation of a germanium gamma-ray detector and its application to efficiency calibration , 2004 .
[30] D. Budjáš,et al. Optimisation of the MC-model of a p-type Ge-spectrometer for the purpose of efficiency determination. , 2009, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.
[31] D. Arnold,et al. On the Monte Carlo simulation of HPGe gamma-spectrometry systems. , 2009, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.
[32] J. Hardy,et al. Precise efficiency calibration of an HPGe detector: source measurements and Monte Carlo calculations with sub-percent precision. , 2002, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.
[33] E R van der Graaf,et al. Monte Carlo based calibration of scintillation detectors for laboratory and in situ gamma ray measurements. , 2011, Journal of environmental radioactivity.
[34] K. Ungar,et al. Testing of an automatic outdoor gamma ambient dose-rate surveillance system in Tokyo and its calibration using measured deposition after the Fukushima nuclear accident. , 2013, Journal of environmental radioactivity.
[35] M. Villa,et al. An intercomparison of Monte Carlo codes used for in-situ gamma-ray spectrometry , 2010 .
[36] J. Pérez‐Moreno,et al. A simple method for efficiency calibration of HPGe detectors in γ-spectrometric measurements , 2001 .
[37] J. Ródenas,et al. Analysis of the influence of germanium dead layer on detector calibration simulation for environmental radioactive samples using the Monte Carlo method , 2003 .
[38] J. Sempau,et al. PENELOPE-2006: A Code System for Monte Carlo Simulation of Electron and Photon Transport , 2009 .
[39] N. C. Díaz,et al. Monte Carlo simulation of the self-absorption corrections for natural samples in gamma-ray spectrometry. , 2002, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.
[40] N. Q. Huy,et al. A study for improving detection efficiency of an HPGe detector based gamma spectrometer using Monte Carlo simulation and genetic algorithms. , 2012, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.
[41] J. Baró,et al. An algorithm for Monte Carlo simulation of coupled electron-photon transport , 1997 .
[42] B. Young,et al. Improved detector response characterization method in ISOCS and LabSOCS , 2005 .
[43] D. Miallier,et al. Ge well detector calibration by means of a trial and error procedure using the dead layers as a unique parameter in a Monte Carlo simulation , 2008 .
[44] Rainer Storn,et al. Differential Evolution – A Simple and Efficient Heuristic for global Optimization over Continuous Spaces , 1997, J. Glob. Optim..
[45] S. Kamboj,et al. Use of Monte Carlo simulation to examine gamma-ray interactions in germanium detectors , 2003 .