Determination of ammonium on an integrated microchip with LED-induced fluorescence detection.

A simply fabricated microfluidic device integrated with a fluorescence detection system has been developed for on-line determination of ammonium in aqueous samples. A 365-nm light-emitting diode (LED) as an excitation source and a minor band pass filter were mounted into a polydimethylsiloxane (PDMS)-based microchip for the purpose of miniaturization of the entire analytical system. The ammonium sample reacted with o-phthaldialdehyde (OPA) on-chip with sodium sulfite as reducing reagent to produce a fluorescent isoindole derivative, which can emit fluorescence signal at about 425 nm when excited at 365 nm. Effects of pH, flow rate of solutions, concentrations of OPA-reagent, phosphate and sulfite salt were investigated. The calibration curve of ammonium in the range of 0.018-1.8 microg/mL showed a good linear relationship with R2 = 0.9985, and the detection limit was (S/N = 3) 3.6 x 10(-4) microg/mL. The relative standard deviation was 2.8% (n = 11) by calculating at 0.18 microg/mL ammonium for repeated detection. The system was applied to determine the ammonium concentration in rain and river waters, even extent to other analytes fluorescence detection by the presented device.

[1]  E. Pelletier,et al.  Determination of ammonium using a microplate-based fluorometric technique. , 2007, Talanta.

[2]  Roger Kerouel,et al.  A simple and precise method for measuring ammonium in marine and freshwater ecosystems , 1999 .

[3]  A. Jouyban,et al.  Development of a Simple and Sensitive Terbium Sensitized Fluorescence Method for Determination of Epinephrine and Norepinephrine in Serum , 2007 .

[4]  Ring-Ling Chien,et al.  Selective ion extraction: a separation method for microfluidic devices. , 2002, Analytical chemistry.

[5]  S. Wakida,et al.  Determination of ammonium in river water and sewage samples by capillary zone electrophoresis with direct UV detection. , 2006, Journal of chromatography. A.

[6]  Takehiko Kitamori,et al.  On-Chip Integration of Neutral Ionophore-Based Ion Pair Extraction Reaction , 2001 .

[7]  Sarah M. Gray,et al.  Spectrophotometric Determination of Ammonia in Estuarine Waters by Hybrid Reagent‐Injection Gas‐Diffusion Flow Analysis , 2006 .

[8]  Yi Zhang,et al.  An integrated fluorescence detection system for lab-on-a-chip applications. , 2007, Lab on a chip.

[9]  J. A. Camargo,et al.  Ecological and toxicological effects of inorganic nitrogen pollution in aquatic ecosystems: A global assessment. , 2006, Environment international.

[10]  J. Michael Ramsey,et al.  Precolumn Reactions with Electrophoretic Analysis Integrated on a Microchip , 1994 .

[11]  M. Macka,et al.  Deep-UV-LEDs in photometric detection: a 255 nm LED on-capillary detector in capillary electrophoresis. , 2009, The Analyst.

[12]  Liduo Wang,et al.  A microfluidic device using a green organic light emitting diode as an integrated excitation source. , 2005, Lab on a chip.

[13]  Chien-Hou Wu,et al.  Fluorometric determination of ammonium ion by ion chromatography using postcolumn derivatization with o-phthaldialdehyde. , 2005, Journal of chromatography. A.

[14]  Syun-Ru Yeh,et al.  Design and evaluation of a passive alcove-based microfluidic mixer. , 2009, Analytical chemistry.

[15]  R. Harrison,et al.  Analysis of atmospheric ammonia and particulate ammonium by a sensitive fluorenscence method. , 1988, Environmental science & technology.

[16]  Jin‐Ming Lin,et al.  Microfluidic cell culture and metabolism detection with electrospray ionization quadrupole time-of-flight mass spectrometer. , 2010, Analytical chemistry.

[17]  L. Clementson,et al.  Flow-injection analysis with fluorescence detection for the determination of trace levels of ammonium in seawater. , 2005, Journal of environmental monitoring : JEM.

[18]  Purnendu K. Dasgupta,et al.  Fluorometric measurement of aqueous ammonium ion in a flow injection system , 1989 .

[19]  Vasan Venugopalan,et al.  Laser-induced mixing in microfluidic channels. , 2007, Analytical chemistry.

[20]  Cheng-Huang Lin,et al.  Determination of riboflavin in urine by capillary electrophoresis-blue light emitting diode-induced fluorescence detection combined with a stacking technique. , 2003, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[21]  M. Munemori,et al.  Continuous flow fluorometric determination of ammonia in water , 1983 .

[22]  T. Johnson,et al.  Rapid microfluidic mixing. , 2002, Analytical chemistry.

[23]  Dafu Cui,et al.  Development of an integrated direct-contacting optical-fiber microchip with light-emitting diode-induced fluorescence detection. , 2007, Journal of chromatography. A.

[24]  P. Campíns-Falcó,et al.  Selective determination of ammonium in water based on HPLC and chemiluminescence detection , 2005 .

[25]  Feng Xu,et al.  Fabrication of microfluidic reactors and mixing studies for luciferase detection. , 2008, Analytical chemistry.

[26]  Xianliang Zhou,et al.  A measurement method for atmospheric ammonia and primary amines based on aqueous sampling, OPA derivatization and HPLC analysis. , 2009, Environmental science & technology.

[27]  Wenzhi Hu,et al.  Selective determination of ammonium ions by high-speed ion-exclusion chromatography on a weakly basic anion-exchange resin column. , 2003, Journal of chromatography. A.

[28]  S. Krupa Effects of atmospheric ammonia (NH3) on terrestrial vegetation: a review. , 2003, Environmental pollution.

[29]  E. D. de Jong,et al.  Low-picomolar limits of detection using high-power light-emitting diodes for fluorescence. , 2006, The Analyst.

[30]  M. Ortiz-Santaliestra,et al.  Effects of ammonium nitrate exposure and water acidification on the dwarf newt: the protective effect of oviposition behaviour on embryonic survival. , 2007, Aquatic toxicology.

[31]  Toru Futami,et al.  Enzymatic degradation of p-chlorophenol in a two-phase flow microchannel system. , 2003, Lab on a chip.

[32]  Toshiro Yamada,et al.  Ammonium detection by formation of colored zebra-bands in a detecting tube. , 2010, Talanta.

[33]  S Meseguer Lloret,et al.  Determination of ammonia and primary amine compounds and Kjeldahl nitrogen in water samples with a modified Roth's fluorimetric method. , 2005, Talanta.

[34]  Ildikó V. Tóth,et al.  Determination of ammonium in marine waters using a gas diffusion multicommuted flow injection system with in-line prevention of metal hydroxides precipitation. , 2009, Journal of environmental monitoring : JEM.