Optimization of a spherical mechanism for a minimally invasive surgical robot: theoretical and experimental approaches

With a focus on design methodology for developing a compact and lightweight minimally invasive surgery (MIS) robot manipulator, the goal of this study is progress toward a next-generation surgical robot system that will help surgeons deliver healthcare more effectively. Based on an extensive database of in-vivo surgical measurements, the workspace requirements were clearly defined. The pivot point constraint in MIS makes the spherical manipulator a natural candidate. An experimental evaluation process helped to more clearly understand the application and limitations of the spherical mechanism as an MIS robot manipulator. The best configuration consists of two serial manipulators in order to avoid collision problems. A complete kinematic analysis and optimization incorporating the requirements for MIS was performed to find the optimal link lengths of the manipulator. The results show that for the serial spherical 2-link manipulator used to guide the surgical tool, the optimal link lengths (angles) are (60/spl deg/, 50/spl deg/). A prototype 6-DOF surgical robot has been developed and will be the subject of further study.

[1]  Jacques Marescaux,et al.  Transatlantic robot-assisted telesurgery , 2001, Nature.

[2]  E. Lerner Computer-integrated surgery. , 1997, New Jersey medicine : the journal of the Medical Society of New Jersey.

[3]  S. Shankar Sastry,et al.  Milli-robotics for remote, minimally invasive surgery , 1997, Robotics Auton. Syst..

[4]  Blake Hannaford,et al.  The BlueDRAGON - a system for measuring the kinematics and dynamics of minimally invasive surgical tools in-vivo , 2002, Proceedings 2002 IEEE International Conference on Robotics and Automation (Cat. No.02CH37292).

[5]  R. Satava Disruptive visions: The operating room of the future , 2003 .

[6]  Y. Matsuoka,et al.  Robotics for surgery. , 1999, Annual review of biomedical engineering.

[7]  Jean-Pierre Merlet,et al.  Parallel Robots , 2000 .

[8]  Blake Hannaford,et al.  Generalized approach for modeling minimally invasive surgery as a stochastic process using a discrete Markov model , 2006, IEEE Transactions on Biomedical Engineering.

[9]  Vivek Kumar,et al.  Optimization of a Spherical Five-Bar Parallel Drive Linkage , 1994 .

[10]  S. C. Venema Experiments in Surface Perception Using a Haptic Display , 1999 .

[11]  Russell H. Taylor,et al.  Robotic total hip replacement surgery in dogs , 1989, Images of the Twenty-First Century. Proceedings of the Annual International Engineering in Medicine and Biology Society,.

[12]  Phillip J. McKerrow,et al.  Introduction to robotics , 1991 .

[13]  Lerner Ej Computer-integrated surgery. , 1997, New Jersey medicine : the journal of the Medical Society of New Jersey.

[14]  Shahram Payandeh,et al.  A Robotic Case Study: Optimal Design for Laparoscopic Positioning Stands , 1998, Int. J. Robotics Res..

[15]  J. D. Brown,et al.  In-Vivo and Postmortem Biomechanics of Abdominal Organs Under Compressive Loads: Experimental Approa , 2003 .

[16]  J. Desai Medical Robotics , 2003 .

[17]  K. Cleary,et al.  State of the art in surgical robotics: clinical applications and technology challenges. , 2001, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[18]  Blake Hannaford,et al.  Kinematic optimization of a spherical mechanism for a minimally invasive surgical robot , 2004, IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004.

[19]  Tsuneo Yoshikawa,et al.  Manipulability and redundancy control of robotic mechanisms , 1985, Proceedings. 1985 IEEE International Conference on Robotics and Automation.

[20]  John Kenneth Salisbury,et al.  The Black Falcon: a teleoperated surgical instrument for minimally invasive surgery , 1998, Proceedings. 1998 IEEE/RSJ International Conference on Intelligent Robots and Systems. Innovations in Theory, Practice and Applications (Cat. No.98CH36190).

[21]  Vincent Hayward,et al.  Multiple-goal kinematic optimization of a parallel spherical mechanism with actuator redundancy , 1992, IEEE Trans. Robotics Autom..

[22]  G. Buess,et al.  Robotics and allied technologies in endoscopic surgery. , 2000, Archives of surgery.

[23]  John J. Craig,et al.  Articulated hands: Force control and kinematic issues , 1981 .

[24]  Shahram Payandeh,et al.  Design of spherical parallel mechanisms for application to laparoscopic surgery , 2002, Robotica.

[25]  B. Hannaford,et al.  Force controlled and teleoperated endoscopic grasper for minimally invasive surgery-experimental performance evaluation , 1999, IEEE Transactions on Biomedical Engineering.

[26]  G. Wnek,et al.  Encyclopedia of biomaterials and biomedical engineering , 2008 .