Sinogram bow-tie filtering in FBP PET reconstruction.

Low-pass filtering of sinograms in the radial direction is the most common practice to limit noise amplification in filtered back projection (FBP) reconstruction of positron emission tomography studies. Other filtering strategies have been proposed to prevent the loss in resolution due to low-pass radial filters, although results have been diverse. Using the well-known properties of the Fourier transform of a sinogram, the authors defined a binary mask that matches the expected shape of the support region in the Fourier domain of the sinogram ("bow tie"). This mask was smoothed by a convolution with a ten-point Gaussian kernel which not only avoids ringing but also introduces a pre-emphasis at low frequencies. A new filtering scheme for FBP is proposed, comprising this smoothed bow-tie filter combined with a standard radial filter and an axial filter. The authors compared the performance of the bow-tie filtering scheme with that of other previously reported methods: Standard radial filtering, angular filtering, and stackgram-domain filtering. All the quantitative data in the comparisons refer to a baseline reconstruction using a ramp filter only. When using the smallest size of the Gaussian kernel in the stackgram domain, the authors achieved a noise reduction of 33% at the cost of degrading radial and tangential resolutions (14.5% and 16%, respectively, for cubic interpolation). To reduce the noise by 30%, the angular filter produced a larger degradation of contrast (3%) and tangential resolution (46% at 10 mm from the center of the field of view) and showed noticeable artifacts in the form of circular blurring dependent on the distance to the center of the field of view. For a similar noise reduction (33%), the proposed bow-tie filtering scheme yielded optimum results in resolution (gain in radial resolution of 10%) and contrast (1% increase) when compared with any of the other filters alone. Experiments with rodent images showed noticeable image quality enhancement when using the proposed bow-tie filtering scheme.

[1]  Robert M. Lewitt,et al.  Fourier correction for spatially variant collimator blurring in SPECT , 1995, IEEE Trans. Medical Imaging.

[2]  S. Cherry,et al.  Observations regarding scatter fraction and NEC measurements for small animal PET , 2006, IEEE Symposium Conference Record Nuclear Science 2004..

[3]  A. Lindgren,et al.  Sampling the 2-D Radon transform , 1981 .

[4]  U. Ruotsalainen,et al.  New Sinogram Filter Design Utilizing Sinusoidal Trajectories , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[5]  H. Zaidi,et al.  Scatter Correction Strategies in Emission Tomography , 2006 .

[6]  Blanca Isabel Andia Nonstationary and Nonlinear Sinogram Filtering for Tomographic Image Reconstruction , 2003 .

[7]  Antti P. Happonen,et al.  A Comparison of Sinogram and Stackgram Domain Filtering Methods Employing L-Filters for Noise Reduction of Tomographic Data , 2005 .

[8]  Ken D. Sauer,et al.  Radially-dependent nonlinear sinogram filtering , 2001, 2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310).

[9]  C. W. Stearns Context-sensitive angular filtering of PET transmission data , 1994, Proceedings of 1994 IEEE Nuclear Science Symposium - NSS'94.

[10]  Michel Defrise,et al.  Exact and approximate rebinning algorithms for 3-D PET data , 1997, IEEE Transactions on Medical Imaging.

[11]  Ronald Boellaard,et al.  Postinjection transmission scanning in myocardial 18F-FDG PET studies using both filtered backprojection and iterative reconstruction. , 2004, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[12]  M. Desco,et al.  Improved image reconstruction in small animal PET using a priori estimates of single-pixel events , 2007, 2007 IEEE Nuclear Science Symposium Conference Record.

[13]  G Muehllehner,et al.  Constrained Fourier space method for compensation of missing data in emission computed tomography. , 1988, IEEE transactions on medical imaging.

[14]  Arion F. Chatziioannou,et al.  Detailed investigation of transmission and emission data smoothing protocols and their effects on emission images , 1996 .

[15]  F. Natterer The Mathematics of Computerized Tomography , 1986 .

[16]  M.E. Daube-Witherspoon,et al.  Investigation of angular and axial smoothing of PET data , 1996, 1996 IEEE Nuclear Science Symposium. Conference Record.

[17]  M. Daube-Witherspoon,et al.  Treatment of axial data in three-dimensional PET. , 1987, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[18]  Paul E Kinahan,et al.  Pragmatic fully 3D image reconstruction for the MiCES mouse imaging PET scanner. , 2004, Physics in medicine and biology.

[19]  Paul R. Edholm,et al.  Novel Properties Of The Fourier Decomposition Of The Sinogram , 1986, Other Conferences.

[20]  Thomas Martin Deserno,et al.  Survey: interpolation methods in medical image processing , 1999, IEEE Transactions on Medical Imaging.

[21]  M. Defrise A factorization method for the 3D X-ray transform , 1995 .

[22]  M. Desco,et al.  rPET detectors design and data processing , 2005, IEEE Nuclear Science Symposium Conference Record, 2005.

[23]  M. E. Daube-Witherspoon,et al.  Investigation of angular smoothing of PET data , 1997 .