Limiting THD of Grid Connected Photovoltaic System using PWM Switching Frequency Selection Based on Solar Irradiance Changing

Photovoltaic (PV) system becomes the best alternative energy to produce electricity that can replace fuel resource. Grid Connected Photovoltaic (GC-PV) system will supply the AC power generated to the utility grid then distributed to the consumer. Solar irradiance in Malaysia varies daily and throughout the year. The consequence of low irradiance level is the output of the PV array is low and thus the input of the inverter relatively becoming low. The inverter will exhibit large non-linearity when the inverter is operating at low power input during low level of solar irradiance and Total Harmonic Distortion (THD) will increased. Pulse Width Modulation (PWM) techniques that are Continuous Pulse Width Modulation (CPWM) and Discontinuous PWM (DPWM) are implemented in the inverter control of the GC-PV system using MATLAB/Simulink environment to investigate the effect of switching frequency on THD at different level of solar irradiance. THD is limit within standard requirement by selecting appropriate value of switching frequency. Results shows that CPWM has better performance in THD and switching losses at selected switching frequency.

[1]  Pradhan Arjyadhara,et al.  Analysis of Solar PV cell Performance with Changing Irradiance and Temperature Pradhan Arjyadhara1, Ali S.M2, J , 2013 .

[2]  Hang Cheng,et al.  Forecasting Research of Long-Term Solar Irradiance and Output Power for Photovoltaic Generation System , 2012 .

[3]  Hasimah Abd Rahman,et al.  Pre-installation Design Simulation Tool for Grid-connected Photovoltaic System Using Iterative Methods☆ , 2015 .

[4]  F. Blaabjerg,et al.  Application of Discontinuous PWMModulation in Active Power Filters , 2008, IEEE Transactions on Power Electronics.

[5]  Salih Mohammed Salih,et al.  Practical Evaluation of Solar Irradiance Effect on PV Performance , 2013 .

[6]  Saeed Mohajeryami,et al.  Effects of photovoltaic systems on power quality , 2016, 2016 North American Power Symposium (NAPS).

[7]  Yun Seng Lim,et al.  Grid-connected photovoltaic system in Malaysia: A review on voltage issues , 2014 .

[8]  Suhaili Beeran Kutty,et al.  Performance and impact analysis of grid connected photovoltaic system to the utility grid , 2014, 2014 IEEE Symposium on Wireless Technology and Applications (ISWTA).

[10]  Ahteshamul Haque,et al.  A simple and effective control of single phase solar inverter , 2017, 2017 International Conference on Power and Embedded Drive Control (ICPEDC).

[11]  Mohammed Harmouchi,et al.  A new strategy to control the active and reactive power for single phase grid-connected PV inverter , 2015, 2015 3rd International Renewable and Sustainable Energy Conference (IRSEC).

[12]  Piyus Mohanty,et al.  Analysis of two level and three level inverters , 2010 .

[13]  Mohd Hendra Hairi,et al.  Investigating the Impact of Photovoltaic Connection to the Malaysian Distribution System , 2016 .

[14]  Ali Q. Al-Shetwi,et al.  Harmonic distortion and voltage imbalance study of photovoltaic power plant connected to the Malaysian grid , 2018 .

[15]  Saurabh Kharjule Voltage source inverter , 2015, 2015 International Conference on Energy Systems and Applications.

[16]  Istvan Erlich,et al.  Control of DFIG based Wind Turbine Converter using Continuous and Discontinuous PWM: A Comparative Study , 2012 .

[17]  Robins Anto,et al.  Harmonics control and performance analysis of a grid connected photovoltaic system , 2013, 2013 International Conference on Advanced Computing and Communication Systems.

[18]  M. Sunwoo,et al.  Variable structure PWM controller for high efficient PV inverters , 2008, 2008 IEEE International Conference on Sustainable Energy Technologies.