Direct laser processing of a tantalum coating on titanium for bone replacement structures.

Recently tantalum is gaining more attention as a new metallic biomaterial as it has been shown to be bioactive and biologically bonds to bone. However, the relatively high cost of manufacture and an inability to produce a modular all Ta implant has limited its widespread acceptance. In this study we have successfully deposited a Ta coating on Ti using laser engineered net shaping (LENS) to enhance the osseointegration properties. In vitro biocompatibility study, using human osteoblast cell line hFOB, showed excellent cellular adherence and growth with abundant extracellular matrix formation on the Ta coating surface compared with the Ti surface. A six times higher living cell density was observed on the Ta coating than on the Ti control surface by MMT assay. A high surface energy and wettability of the Ta surface were observed to contribute to its significantly better cell-material interactions. Also, these dense Ta coatings do not suffer from low fatigue resistance due to the absence of porosity and a sharp interface between the coating and the substrate, which is a major concern for porous coatings used for enhanced/early biological fixation.

[1]  R. Pilliar,et al.  The fatigue strength of porous-coated Ti-6%Al-4%V implant alloy. , 1984, Journal of biomedical materials research.

[2]  H. Skinner,et al.  Fatigue properties of carbon- and porous-coated Ti-6Al-4V alloy. , 1984, Journal of biomedical materials research.

[3]  B. Vamsi Krishna,et al.  Laser Processing of Net-Shape NiTi Shape Memory Alloy , 2007 .

[4]  I Macnab,et al.  The rate of bone ingrowth into porous metal. , 1976, Journal of biomedical materials research.

[5]  H. M. Kim,et al.  Bonding of alkali- and heat-treated tantalum implants to bone. , 2000, Journal of biomedical materials research.

[6]  A. Bandyopadhyay,et al.  Surface modifications and cell-materials interactions with anodized Ti. , 2007, Acta biomaterialia.

[7]  Michael Tanzer,et al.  Tissue response to porous tantalum acetabular cups: a canine model. , 1999, The Journal of arthroplasty.

[8]  Masakazu Kawashita,et al.  Novel bioactive materials with different mechanical properties. , 2003, Biomaterials.

[9]  Amit Bandyopadhyay,et al.  Functionally graded Co-Cr-Mo coating on Ti-6Al-4V alloy structures. , 2008, Acta biomaterialia.

[10]  A. Yokoyama,et al.  Biocompatibility and osteogenesis of refractory metal implants, titanium, hafnium, niobium, tantalum and rhenium. , 2001, Biomaterials.

[11]  M. Traisnel,et al.  Surface analyses of micro-arc oxidized and hydrothermally treated titanium and effect on osteoblast behavior. , 2004, Journal of biomedical materials research. Part A.

[12]  Amit Bandyopadhyay,et al.  Application of Laser Engineered Net Shaping (LENS) to manufacture porous and functionally graded structures for load bearing implants , 2009, Journal of materials science. Materials in medicine.

[13]  I Macnab,et al.  Porous surface layered prosthetic devices. , 1975, Biomedical engineering.

[14]  Michael Tanzer,et al.  Characteristics of bone ingrowth and interface mechanics of a new porous tantalum biomaterial. , 1999, The Journal of bone and joint surgery. British volume.

[15]  Vamsi Krishna Balla,et al.  Fabrication of compositionally and structurally graded Ti-TiO2 structures using laser engineered net shaping (LENS). , 2009, Acta biomaterialia.

[16]  C. Ohtsuki,et al.  Mechanism of bonelike apatite formation on bioactive tantalum metal in a simulated body fluid. , 2002, Biomaterials.

[17]  R. Barrack,et al.  Tissue growth into porous primary and revision femoral stems. , 1991, The Journal of arthroplasty.

[18]  M. Bermúdez,et al.  Erosion–corrosion of stainless steels, titanium, tantalum and zirconium , 2005 .

[19]  L. Sedel,et al.  Behavior of human osteoblastic cells on stoichiometric hydroxyapatite and type A carbonate apatite: role of surface energy. , 2000, Journal of biomedical materials research.

[20]  B Vamsi Krishna,et al.  Fabrication of porous NiTi shape memory alloy structures using laser engineered net shaping. , 2009, Journal of biomedical materials research. Part B, Applied biomaterials.

[21]  R M Pilliar,et al.  The optimum pore size for the fixation of porous-surfaced metal implants by the ingrowth of bone. , 1980, Clinical orthopaedics and related research.

[22]  B Vamsi Krishna,et al.  Low stiffness porous Ti structures for load-bearing implants. , 2007, Acta biomaterialia.

[23]  Pilliar Rm,et al.  Powder metal-made orthopedic implants with porous surface for fixation by tissue ingrowth. , 1983 .

[24]  Amit Bandyopadhyay,et al.  Laser processing of bioactive tricalcium phosphate coating on titanium for load-bearing implants. , 2008, Acta biomaterialia.

[25]  R. Barrack,et al.  Quantitative analysis of tissue growth into human porous total hip components. , 1988, The Journal of arthroplasty.

[26]  J. Chae,et al.  Macroscopic and microscopic evidence of prosthetic fixation with porous-coated materials. , 1988, Clinical orthopaedics and related research.

[27]  A. Bandyopadhyay,et al.  Laser-assisted Zr/ZrO(2) coating on Ti for load-bearing implants. , 2009, Acta biomaterialia.

[28]  H. Skinner,et al.  Current concepts in orthopaedic biomaterials and implant fixation. , 1993, Instructional course lectures.

[29]  Amit Bandyopadhyay,et al.  Engineered porous metals for implants , 2008 .

[30]  M Jasty,et al.  Histological and radiographic assessment of well functioning porous-coated acetabular components. A human postmortem retrieval study. , 1993, The Journal of bone and joint surgery. American volume.

[31]  P. Tresco,et al.  Relative importance of surface wettability and charged functional groups on NIH 3T3 fibroblast attachment, spreading, and cytoskeletal organization. , 1998, Journal of biomedical materials research.

[32]  D R Sumner,et al.  A quantitative study of bone and soft tissues in cementless porous-coated acetabular components retrieved at autopsy. , 1993, The Journal of arthroplasty.

[33]  D. Kohn,et al.  A parametric study of the factors affecting the fatigue strength of porous coated Ti-6A1-4V implant alloy. , 1990, Journal of biomedical materials research.

[34]  W. Duley Co2 Lasers: Effects and Applications , 1976 .

[35]  Michael Tanzer,et al.  Fibrous tissue ingrowth and attachment to porous tantalum. , 2000, Journal of biomedical materials research.

[36]  J. Galante,et al.  Sintered fiber metal composites as a basis for attachment of implants to bone. , 1971, The Journal of bone and joint surgery. American volume.

[37]  B Vamsi Krishna,et al.  Processing and biocompatibility evaluation of laser processed porous titanium. , 2007, Acta biomaterialia.