Optimisation in diagnostic radiology requires accurate methods for determination of patient absorbed dose and clinical image quality. Simple methods for evaluation of clinical image quality are at present scarce and this project aims at developing such methods. Two methods are used and further developed; fulfilment of image criteria (IC) and visual grading analysis (VGA). Clinical image quality descriptors are defined based on these two methods: image criteria score (ICS) and visual grading analysis score (VGAS), respectively. For both methods the basis is the Image Criteria of the “European Guidelines on Quality Criteria for Diagnostic Radiographic Images”. Both methods have proved to be useful for evaluation of clinical image quality. The two methods complement each other: IC is an absolute method, which means that the quality of images of different patients and produced with different radiographic tech-niques can be compared with each other. The separating power of IC is, however, weaker than that of VGA. VGA is the best method for comparing images produced with different radiographic techniques and has strong separating power, but the re-sults are relative, since the quality of an image is compared to the quality of a refer-ence image.
The usefulness of the two methods has been verified by comparing the results from both of them with results from a generally accepted method for evaluation of clinical image quality, receiver operating characteristics (ROC). The results of the comparison between the two methods based on visibility of anatomical structures and the method based on detection of pathological structures (free-response forced error) indicate that the former two methods can be used for evaluation of clinical image quality as efficiently as the method based on ROC. More studies are, however, needed for us to be able to draw a general conclusion, including studies of other organs, using other radiographic techniques, etc.
The results of the experimental evaluation of clinical image quality are compared with physical quantities calculated with a theoretical model based on a voxel phantom, and correlations are found. The results demonstrate that the computer model can be a useful tool in planning further experimental studies.
[1]
Michael Sandborg,et al.
Calibration and validation of a voxel phantom for use in the Monte Carlo modeling and optimization of x-ray imaging systems
,
1999,
Medical Imaging.
[2]
L B Lusted,et al.
Factors affecting the detectability of a simulated radiographic signal.
,
1973,
Investigative radiology.
[3]
A E Burgess,et al.
Visual signal detection. II. Signal-location identification.
,
1984,
Journal of the Optical Society of America. A, Optics and image science.
[4]
C. Metz.
ROC Methodology in Radiologic Imaging
,
1986,
Investigative radiology.
[5]
D. C. Barber,et al.
Medical Imaging-The Assessment of Image Quality
,
1996
.
[6]
M Zankl,et al.
The influence of different technique factors on image quality of lumbar spine radiographs as evaluated by established CEC image criteria.
,
2000,
The British journal of radiology.
[7]
John A. Swets,et al.
Evaluation of diagnostic systems : methods from signal detection theory
,
1982
.
[8]
D R Dance,et al.
A Monte Carlo program for the calculation of contrast, noise and absorbed dose in diagnostic radiology.
,
1994,
Computer methods and programs in biomedicine.
[9]
D. Hoeschen,et al.
Correlation Between Physical Image Quality Parameters and Visually Perceptible Image Quality in X-Ray Diagnosis
,
1993
.
[10]
B B Hobbs,et al.
Detection accuracy in chest radiography.
,
1978,
AJR. American journal of roentgenology.
[11]
M Sandborg,et al.
Evaluation of image quality in fluoroscopy by measurements and Monte Carlo calculations.
,
1995,
Physics in medicine and biology.
[12]
Lars Gunnar Månsson.
Evaluation of radiographic procedures : investigations related to chest imaging
,
1994
.
[13]
J. Hanley.
Receiver operating characteristic (ROC) methodology: the state of the art.
,
1989,
Critical reviews in diagnostic imaging.
[14]
M J Yaffe,et al.
Model of the spatial-frequency-dependent detective quantum efficiency of phosphor screens.
,
1990,
Medical physics.