Drift Removal for Improving the Accuracy of Gait Parameters Using Wearable Sensor Systems

Accumulated signal noise will cause the integrated values to drift from the true value when measuring orientation angles of wearable sensors. This work proposes a novel method to reduce the effect of this drift to accurately measure human gait using wearable sensors. Firstly, an infinite impulse response (IIR) digital 4th order Butterworth filter was implemented to remove the noise from the raw gyro sensor data. Secondly, the mode value of the static state gyro sensor data was subtracted from the measured data to remove offset values. Thirdly, a robust double derivative and integration method was introduced to remove any remaining drift error from the data. Lastly, sensor attachment errors were minimized by establishing the gravitational acceleration vector from the acceleration data at standing upright and sitting posture. These improvements proposed allowed for removing the drift effect, and showed an average of 2.1°, 33.3°, 15.6° difference for the hip knee and ankle joint flexion/extension angle, when compared to without implementation. Kinematic and spatio-temporal gait parameters were also calculated from the heel-contact and toe-off timing of the foot. The data provided in this work showed potential of using wearable sensors in clinical evaluation of patients with gait-related diseases.

[1]  Johan Kärrholm,et al.  Changed gait pattern in patients with total knee arthroplasty but minimal influence of tibial insert design , 2005, Acta orthopaedica.

[2]  Volker Dietz,et al.  Assessing walking ability in subjects with spinal cord injury: validity and reliability of 3 walking tests. , 2005, Archives of physical medicine and rehabilitation.

[3]  Aurelio Cappozzo,et al.  An optimized Kalman filter for the estimate of trunk orientation from inertial sensors data during treadmill walking. , 2012, Gait & posture.

[4]  Pascal Fua,et al.  Estimation and visualization of sagittal kinematics of lower limbs orientation using body-fixed sensors , 2006, IEEE Transactions on Biomedical Engineering.

[5]  Sofiane Ramdani,et al.  Integration of Human Walking Gyroscopic Data Using Empirical Mode Decomposition , 2013, Sensors.

[6]  S. Simon Gait Analysis, Normal and Pathological Function. , 1993 .

[7]  M A Brodie,et al.  The static accuracy and calibration of inertial measurement units for 3D orientation , 2008, Computer methods in biomechanics and biomedical engineering.

[8]  I-Ming Chen,et al.  Localization and velocity tracking of human via 3 IMU sensors , 2014 .

[9]  M H Granat,et al.  A practical gait analysis system using gyroscopes. , 1999, Medical engineering & physics.

[10]  Alfred D. Grant Gait Analysis: Normal and Pathological Function , 2010 .

[11]  J R Morris,et al.  Accelerometry--a technique for the measurement of human body movements. , 1973, Journal of biomechanics.

[12]  Friedrich Foerster,et al.  Detection of posture and motion by accelerometry : a validation study in ambulatory monitoring , 1999 .

[13]  P H Veltink,et al.  Detection of static and dynamic activities using uniaxial accelerometers. , 1996, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[14]  Kristian Overgaard,et al.  Relations between 6 minute walking distance and 10 meter walking speed in patients with multiple sclerosis and stroke. , 2012, Archives of physical medicine and rehabilitation.

[15]  Stefano Pastorelli,et al.  A Biomechanical Approach to Paralympic Cross-Country Sit-Ski Racing , 2012, Clinical journal of sport medicine : official journal of the Canadian Academy of Sport Medicine.

[16]  Masahiro Todoh,et al.  Gait posture estimation using wearable acceleration and gyro sensors. , 2009, Journal of biomechanics.

[17]  Tao Liu,et al.  Development of a wearable sensor system for quantitative gait analysis , 2009 .

[18]  Ryo Takeda,et al.  Gait analysis using gravitational acceleration measured by wearable sensors. , 2009, Journal of biomechanics.

[19]  Shuozhi Yang,et al.  Estimation of spatio-temporal parameters for post-stroke hemiparetic gait using inertial sensors. , 2013, Gait & posture.

[20]  P H Veltink,et al.  Ambulatory measurement of arm orientation. , 2007, Journal of biomechanics.

[21]  S R Simon,et al.  Quantitative gait analysis after total knee arthroplasty for monarticular degenerative arthritis. , 1983, The Journal of bone and joint surgery. American volume.

[22]  Christopher Kirtley,et al.  Clinical Gait Analysis: Theory and Practice , 2006 .

[23]  Shigeru Tadano,et al.  Three Dimensional Gait Analysis Using Wearable Acceleration and Gyro Sensors Based on Quaternion Calculations , 2013, Sensors.

[24]  J. Allum,et al.  Gait event detection using linear accelerometers or angular velocity transducers in able-bodied and spinal-cord injured individuals. , 2006, Gait & posture.

[25]  Aurelio Cappozzo,et al.  Joint kinematics estimate using wearable inertial and magnetic sensing modules. , 2008, Gait & posture.

[26]  Denise M. Peters,et al.  Assessing the Reliability and Validity of a Shorter Walk Test Compared With the 10-Meter Walk Test for Measurements of Gait Speed in Healthy, Older Adults , 2013, Journal of geriatric physical therapy.

[27]  Peter H. Veltink,et al.  Measuring orientation of human body segments using miniature gyroscopes and accelerometers , 2005, Medical and Biological Engineering and Computing.

[28]  J. D. Janssen,et al.  A triaxial accelerometer and portable data processing unit for the assessment of daily physical activity , 1997, IEEE Transactions on Biomedical Engineering.

[29]  K. Aminian,et al.  Ambulatory measurement of 3D knee joint angle. , 2008, Journal of biomechanics.

[30]  D. Lloyd,et al.  Pre‐surgery knee joint loading patterns during walking predict the presence and severity of anterior knee pain after total knee arthroplasty , 2004, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[31]  K. Aminian,et al.  Quaternion-based fusion of gyroscopes and accelerometers to improve 3D angle measurement , 2006 .