Left and right pump output control in one-piece electromechanical total artificial heart.

Left master alternate (LMA) ejection control based on the left pump fill method was implemented for a one-piece electromechanical total artificial heart (TAH). The TAH consists of left and right pusher-plate-type blood pumps sandwiching a compact electromechanical actuator comprising a direct current (DC) brushless motor and a planetary roller screw. The motor rotation is controlled on the basis of the roller-screw position as detected by a Hall effect sensor and a commutation pulse counting method. Since the pusher-plate shaft and roller screw are decoupled during filling, both pumps fill passively with the right and left atrial pressure. To obtain response to the right atrial pressure change in the LMA mode, the left fill trigger level as detected by a Hall effect position sensor is adjusted to operate the pump at a higher rate and to drive the right pump at 85-90% of the full stroke level. The in vitro evaluation demonstrated that this method can respond to right atrial pressure changes provided that the right pump is operated at less than the full stroke level. When the preload is high and the right pump goes into full stroke operation, the left eject level can be decreased to run the pump at a higher rate and to transfer more blood from the right to the left. In the in vivo evaluation, which lasted 1 week in a 95 kg calf, the left and right atrial pressures were kept within physiological ranges.(ABSTRACT TRUNCATED AT 250 WORDS)

[1]  R Kiraly,et al.  Pusher-plate type TAH system operated in the left and right free-running variable rate mode. , 1981, Artificial organs.

[2]  Y Nosé,et al.  Characterization of rehydrated gelatin gels. , 2008, Artificial organs.

[3]  Y Nosé,et al.  Intraoperative determination of mediastinal constraints for a total artificial heart. , 1991, ASAIO transactions.

[4]  R. Kung,et al.  A unique left-right flow imbalance compensation scheme for an implantable total artificial heart. , 1989, ASAIO transactions.

[5]  D B Olsen,et al.  Right-Left Ventricular output Balance in the Totally Implantable Artificial Heart , 1991, The International journal of artificial organs.

[6]  Y. Nosé Toward a totally implantable artificial heart: Development status at Cleveland Clinic , 1991 .

[7]  S Takatani,et al.  Simultaneously ejecting left-or-right triggered total artificial heart actuated by a single electromechanical system. , 1985, Transactions - American Society for Artificial Internal Organs.

[8]  D Hillegass,et al.  HIGH FLEX RUBBER FOR BLOOD PUMP DIAPHRAGMS , 1977, Transactions - American Society for Artificial Internal Organs.

[9]  D.B. Geselowitz,et al.  Permanent circulatory support systems at the Pennsylvania State University , 1990, IEEE Transactions on Biomedical Engineering.

[10]  S Takatani,et al.  A unique, efficient, implantable, electromechanical, total artificial heart. , 1991, ASAIO transactions.

[11]  H. Harasaki,et al.  Transient and permanent problems associated with the total artificial heart implantation. , 1979, Transactions - American Society for Artificial Internal Organs.