Endothelial lamellar keratoplasty using an artificial anterior chamber and a microkeratome.

OBJECTIVE To compare postoperative astigmatic change and graft stability using 2 different donor button diameters in endothelial lamellar keratoplasty to treat corneal endothelial failure. METHODS A 200- micro m-thick corneal flap keratectomy was performed in human donor corneoscleral rims (n = 20; 10 donors and 10 recipients) using an artificial anterior chamber and a manual microkeratome (ALTK System; Moria USA, Doylestown, Pa). After flap reflection, stromal bed trephination was performed to obtain a disc consisting of posterior stroma, Descemet membrane, and endothelium. Host beds of 7.0 mm and 7.25-mm (n = 5) or 7.50-mm (n = 5) donor buttons were obtained using a freehand trephine. The graft was secured with 8 interrupted sutures (10-0 nylon) in the stromal bed. The flap was sutured with 3 interrupted sutures. Transplanted corneas were submitted to increasing intrachamber pressures to detect graft stability, and preoperative and postoperative videokeratographic data were recorded to assess astigmatic change. RESULTS The mean (SD) postoperative astigmatic change was 1.14 (3.17) diopters (D) in the 7.25-mm donor button group and 2.27 (1.77) D in the 7.50-mm donor button group (P =.69). Mean (SD) resisted pressures of 75.4 (44.81) mm Hg and 100.4 (46.86) mm Hg were observed in the 7.25-mm and 7.50-mm groups, respectively (P =.54). CONCLUSION Both donor button sizes exhibited similar graft stability and astigmatic postoperative change in this experimental model. CLINICAL RELEVANCE As endothelial lamellar keratoplasty becomes further developed as a clinical alternative to penetrating keratoplasty, this laboratory model system should be useful in evaluating different mechanical factors that contribute to graft success.

[1]  A. Behrens,et al.  A Laboratory Model for Microkeratome-Assisted Posterior Lamellar Keratoplasty Utilizing a Running Graft Suture and a Sutureless Hinged Flap , 2002, Cornea.

[2]  Mark J Mannis,et al.  Summary of Corneal Transplant Activity: Eye Bank Association of America , 2002, Cornea.

[3]  D. Azar,et al.  Microkeratome-assisted posterior keratoplasty. , 2001, Journal of cataract and refractive surgery.

[4]  A. Behrens,et al.  Precision and accuracy of an artificial anterior chamber system in obtaining corneal lenticules for lamellar keratoplasty , 2001, Journal of cataract and refractive surgery.

[5]  M. Terry,et al.  Endothelial Replacement Without Surface Corneal Incisions or Sutures: Topography of the Deep Lamellar Endothelial Keratoplasty Procedure , 2001, Cornea.

[6]  S. Jain,et al.  Microkeratome-assisted posterior keratoplasty. , 2001, Journal of cataract and refractive surgery.

[7]  M. Busin,et al.  Endokeratoplasty as an alternative to penetrating keratoplasty for the surgical treatment of diseased endothelium: initial results. , 2000, Ophthalmology.

[8]  T. Møller-Pedersen,et al.  Grafting of the posterior cornea. Description of a new technique with 12-month clinical results. , 2000, Acta ophthalmologica Scandinavica.

[9]  E. Pels,et al.  Preliminary clinical results of posterior lamellar keratoplasty through a sclerocorneal pocket incision. , 2000, Ophthalmology.

[10]  M. Terry The Evolution of Lamellar Grafting Techniques Over Twenty-five Years , 2000, Cornea.

[11]  P. McDonnell Emergence of refractive surgery. , 2000, Archives of ophthalmology.

[12]  U. Schlötzer-Schrehardt,et al.  Keratopathy in pseudoexfoliation syndrome as a cause of corneal endothelial decompensation: a clinicopathologic study. , 2000, Ophthalmology.

[13]  A Langenbucher,et al.  Experimental evaluation of two current-generation automated microkeratomes: the Hansatome and the Supratome. , 2000, American journal of ophthalmology-glaucoma.

[14]  P. Eggli,et al.  Morphological and functional analysis of immortalized human corneal endothelial cells after transplantation. , 1999, Experimental eye research.

[15]  B. Seitz,et al.  Nonmechanical corneal trephination with the excimer laser improves outcome after penetrating keratoplasty. , 1999, Ophthalmology.

[16]  A. Behrens,et al.  Evaluation of corneal flap dimensions and cut quality using a manually guided microkeratome. , 1999, Journal of refractive surgery.

[17]  P. Binder,et al.  Posterior lamellar keratoplasty for a case of pseudophakic bullous keratopathy. , 1999, American journal of ophthalmology.

[18]  E. Pels,et al.  A surgical technique for posterior lamellar keratoplasty. , 1998, Cornea.

[19]  A. Behrens,et al.  Experimental 193-nm excimer laser trephination with divergent cut angles in penetrating keratoplasty. , 1998, Cornea.

[20]  R. Chuck,et al.  Screening of myopic photorefractive keratectomy in eye bank eyes by computerized videokeratography. , 1998, Archives of ophthalmology.

[21]  I. Schwab,et al.  Comparison of astigmatism after penetrating keratoplasty by experienced cornea surgeons and cornea fellows. , 1997, American journal of ophthalmology.

[22]  B. Seitz,et al.  Endotheliale Keratopathie bei Pseudoexfoliationssyndrom: Quantitative und qualitative Morphometrie mittels automatisierter Videobildanalyse , 1995 .

[23]  T. Wood,et al.  Transplantation of Corneal Endothelial Cells Using a Cell Carrier Device , 1994, Cornea.

[24]  R C Troutman,et al.  Astigmatism after penetrating keratoplasty using the Krumeich guided trephine system. , 1993, Refractive & corneal surgery.

[25]  I G Pallikaris,et al.  A corneal flap technique for laser in situ keratomileusis. Human studies. , 1991, Archives of ophthalmology.

[26]  W. Culbertson,et al.  Optical lamellar keratoplasty using the barraquer microkeratome. , 1991, Refractive & corneal surgery.

[27]  E. Perlman,et al.  An analysis and interpretation of refractive errors after penetrating keratoplasty. , 1981, Ophthalmology.

[28]  D. Maurice,et al.  Corneal endothelial transplantation. , 1980, Ophthalmology.

[29]  D. Gospodarowicz,et al.  Transplantation of cultured bovine corneal endothelial cells to rabbit cornea: clinical implications for human studies. , 1979, Proceedings of the National Academy of Sciences of the United States of America.

[30]  D. Maurice,et al.  Transplantation of tissue-cultured corneal endothelium. , 1978, Investigative ophthalmology & visual science.

[31]  B. Ji Lamellar keratoplasty. (Special techniques). , 1972 .

[32]  J. Barraquer Lamellar keratoplasty. (Special techniques). , 1972, Annals of ophthalmology.