Review of PSS Based on WAMS Suppressing Low Frequency Oscillation of Interconnected Power Grid

With the development of power grid interconnection, the low frequency oscillation including local modes and inter-area modes is becoming more notable. And the effectiveness of local power system stabilizer (LPSS) in damping inter-area modes is not very well. Then the global PSS (GPSS) based on WAMS (wide area measurement system) is proposed which is aimed to damp inter-area modes. This paper summarizes the proposal of the GPSS based on WAMS and describes 4 problems about the global damping control: model identification, the design of GPSS, the choice of GPSS location and input signals. Then the delay and reliability for the global damping control are analyzed. Some new viewpoints and solutions based on WAMS in monitoring and analysis of low frequency oscillations are researched. The deep research on applications of WAMS in power systems is worth much.

[1]  H. F. Wang,et al.  Indices for selecting the best location of PSSs or FACTS-based stabilisers in multimachine power systems: a comparative study , 1997 .

[2]  A.G. Phadke,et al.  Wide Area Protection—Technology and Infrastructures , 2006, IEEE Transactions on Power Delivery.

[3]  Hui Xue,et al.  Decentralized stabilizer design for model-uncertain large interconnected power systems based on WAMS , 2007, 2007 International Power Engineering Conference (IPEC 2007).

[4]  Paul M. Anderson Power System Protection , 1998 .

[5]  Shaopeng Wang,et al.  Power system damping controller design-using multiple input signals , 2000 .

[6]  K. Uhlen,et al.  Monitoring amplitude, frequency and damping of power system oscillations with PMU measurements , 2008, 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century.

[7]  Lamine Mili,et al.  Power system stability agents using robust wide area control , 2002 .

[8]  Xiaorong Xie,et al.  WAMS applications in Chinese power systems , 2006 .

[9]  Zhijian Hu,et al.  Robust stability control of power systems based on WAMs , 2008, 2008 Chinese Control and Decision Conference.

[10]  Jing Zhang,et al.  Realization of the WAMS based power system aggregate load area model , 2008, 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century.

[11]  J. F. Hauer Validation of phasor calculations in the macrodyne PMU for California-Oregon Transmission Project tests of March 1993 , 1996 .

[12]  Christian Rehtanz,et al.  Design Aspects for Wide-Area Monitoring and Control Systems , 2005, Proceedings of the IEEE.

[13]  James S. Thorp,et al.  Power System Protection , 2000 .

[14]  T.S. Bi,et al.  Study on wide area measurement system based transient stability control for power system , 2005, 2005 International Power Engineering Conference.

[15]  Tianshu Bi,et al.  WAMS Implementation in China and the Challenges for Bulk Power System Protection , 2007, 2007 IEEE Power Engineering Society General Meeting.