MEMS Capacitive Accelerometer-Based Middle Ear Microphone

The design, implementation, and characterization of a microelectromechanical systems (MEMS) capacitive accelerometer-based middle ear microphone are presented in this paper. The microphone is intended for middle ear hearing aids as well as future fully implantable cochlear prosthesis. Human temporal bones acoustic response characterization results are used to derive the accelerometer design requirements. The prototype accelerometer is fabricated in a commercial silicon-on-insulator (SOI) MEMS process. The sensor occupies a sensing area of 1 mm × 1 mm with a chip area of 2 mm × 2.4 mm and is interfaced with a custom-designed low-noise electronic IC chip over a flexible substrate. The packaged sensor unit occupies an area of 2.5 mm × 6.2 mm with a weight of 25 mg. The sensor unit attached to umbo can detect a sound pressure level (SPL) of 60 dB at 500 Hz, 35 dB at 2 kHz, and 57 dB at 8 kHz. An improved sound detection limit of 34-dB SPL at 150 Hz and 24-dB SPL at 500 Hz can be expected by employing start-of-the-art MEMS fabrication technology, which results in an articulation index of approximately 0.76. Further micro/nanofabrication technology advancement is needed to enhance the microphone sensitivity for improved understanding of normal conversational speech.

[1]  Michael A. Suster,et al.  A High-Performance MEMS Capacitive Strain Sensing System , 2006 .

[2]  Rafael Urquiza,et al.  Tympanic-ossicular prostheses and MEMS technology: whats and whys , 2009, Acta oto-laryngologica.

[3]  Darrin J. Young,et al.  Effect of Incus Removal on Middle Ear Acoustic Sensor for a Fully Implantable Cochlear Prosthesis , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[4]  Rui Zhang,et al.  Studies of MEMS Acoustic Sensors as Implantable Microphones for Totally Implantable Hearing-Aid Systems , 2009, IEEE Transactions on Biomedical Circuits and Systems.

[5]  Rudolf Häusler,et al.  A Novel Implantable Hearing System with Direct Acoustic Cochlear Stimulation , 2008, Audiology and Neurotology.

[6]  Wen H. Ko,et al.  Bioelectronic microphone options for a totally implantable hearing device for partial and total hearing loss , 2001 .

[7]  T. Gabrielson Mechanical-thermal noise in micromachined acoustic and vibration sensors , 1993 .

[8]  John J. Rosowski,et al.  Acoustic responses of the human middle ear , 2000, Hearing Research.

[9]  Jun Guo,et al.  A High-Performance MEMS Capacitive Strain Sensing System , 2006, Journal of Microelectromechanical Systems.

[10]  Chris J James,et al.  An Investigation of Input Level Range for the Nucleus 24 Cochlear Implant System: Speech Perception Performance, Program Preference, and Loudness Comfort Ratings , 2003, Ear and hearing.

[11]  Rong Z Gan,et al.  Human Middle Ear Transfer Function Measured by Double Laser Interferometry System , 2004, Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology.

[12]  John J. Rosowski,et al.  Cadaver Middle Ears as Models for Living Ears: Comparisons of Middle Ear Input Immittance , 1990, The Annals of otology, rhinology, and laryngology.

[13]  Rong Z. Gan,et al.  Mass Loading on the Ossicles and Middle Ear Function , 2001, The Annals of otology, rhinology, and laryngology.

[14]  Saumil N Merchant,et al.  A normative study of tympanic membrane motion in humans using a laser Doppler vibrometer (LDV) , 2004, Hearing Research.

[15]  Joachim W. Baumann,et al.  Patient selection for incus body coupling of a totally implantable middle ear implant , 2003, Acta oto-laryngologica.

[16]  W H Ko,et al.  Engineering principles applied to implantable otologic devices. , 2001, Otolaryngologic clinics of North America.

[17]  R. Goode,et al.  Effect of Changes in Mass on Middle Ear Function , 1993, Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery.

[18]  Fan-Gang Zeng,et al.  Cochlear Implants: System Design, Integration, and Evaluation , 2008, IEEE Reviews in Biomedical Engineering.

[19]  M. Dorman,et al.  Performance of Patients Using Different Cochlear Implant Systems: Effects of Input Dynamic Range , 2007, Ear and hearing.

[20]  Woo-Tae Park,et al.  Sub-mm encapsulated accelerometers: a fully implantable sensor for cochlear implants , 2005, The 13th International Conference on Solid-State Sensors, Actuators and Microsystems, 2005. Digest of Technical Papers. TRANSDUCERS '05..

[21]  Michel Mondain,et al.  Rehabilitation for High-Frequency Sensorineural Hearing Impairment in Adults with the Symphonix Vibrant Soundbridge: A Comparative Study , 2003, Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology.

[22]  Jin-Ho Cho,et al.  Design of differential electromagnetic transducer for implantable middle ear hearing device using finite element method , 2006 .

[23]  G. Ball,et al.  Measurement of umbo vibration in human subjects--method and possible clinical applications. , 1993, The American journal of otology.

[24]  Fan-Gang Zeng,et al.  Speech dynamic range and its effect on cochlear implant performance. , 2002, The Journal of the Acoustical Society of America.

[25]  C. Toumazou,et al.  A 126-/spl mu/W cochlear chip for a totally implantable system , 2005, IEEE Journal of Solid-State Circuits.