Spectrophotometer Ageing and Prediction of Fruit Attributes

Deterioration of lamp output quality over time and degradation of detector signal-to-noise ratio are issues associated with ageing of a spectrophotometer. To document the effect of instrument ageing on short wavelength near infrared spectroscopy-based assessment of internal attributes of fruit quality prediction (total soluble solids, TSS, of juice), an assessment was conducted of several handheld photodiode array-based spectrophotometers over several years, with repeated spectra of a reference Teflon (PTFE) tile and spectra of 20 apple fruit acquired at yearly intervals. The repeatability of each instrument was assessed as the standard deviation of absorbance of repeated measures of a reference, typically around 0.2 mAbs. Instrument changes were identified in performance and in principal components analysis plots, but performance (apple TSS model) was not related to instrument repeatability. A piecewise direct standardisation method is recommended to maintain a multivariate calibration model across spectrometers.

[1]  T. Fearn Standardisation and Calibration Transfer for near Infrared Instruments: A Review , 2001 .

[2]  Dominique Bonvin,et al.  Framework for explicit drift correction in multivariate calibration models , 2010 .

[3]  Kaiyi Zheng,et al.  A Robust Near-Infrared Calibration Model for the Determination of Chlorophyll Concentration in Tree Leaves with a Calibration Transfer Method , 2015 .

[4]  B. Kowalski,et al.  Multivariate instrument standardization , 1991 .

[5]  K. Walsh,et al.  A remote acceptance probe and illumination configuration for spectral assessment of internal attributes of intact fruit , 2000 .

[6]  Robert B Jordan,et al.  Temporal Sensitivity of the Wavelength Calibration of a Photodiode Array Spectrometer , 2010, Applied spectroscopy.

[7]  J. Roger,et al.  Robustness of Models Based on NIR Spectra for Sugar Content Prediction in Apples , 2003 .

[8]  K. Walsh,et al.  Optimization of Instrumentation Precision and Wavelength Resolution for the Performance of NIR Calibrations of Sucrose in a Water—Cellulose Matrix , 2000 .

[9]  Jean-Michel Roger,et al.  Calibration transfer of intact olive NIR spectra between a pre-dispersive instrument and a portable spectrometer , 2013 .

[10]  Tom Fearn,et al.  Transfer by orthogonal projection: making near-infrared calibrations robust to between-instrument variation , 2004 .

[11]  Steven D. Brown,et al.  Transfer of multivariate calibration models: a review , 2002 .

[12]  Nils Bo Büchmann,et al.  The Standardisation of Infratec 1221 near Infrared Transmission Instruments in the Danish Network Used for the Determination of Protein and Moisture in Grains , 1995 .

[13]  K. Walsh,et al.  Temporal and Environmental Sensitivity of a Photodiode Array Spectrophometric System , 2014 .

[14]  Miguel Lopo,et al.  A Review on the Applications of Portable Near-Infrared Spectrometers in the Agro-Food Industry , 2013, Applied spectroscopy.

[15]  K. Walsh,et al.  Calibration Transfer between Miniature Photodiode Array-Based Spectrometers in the near Infrared Assessment of Mandarin Soluble Solids Content , 2002 .

[16]  C. Spiegelman,et al.  Calibration Transfer between PDA-Based NIR Spectrometers in the NIR Assessment of Melon Soluble Solids Content , 2001 .

[17]  J. Guthrie,et al.  Application of commercially available, low-cost, miniaturised NIR spectrometers to the assessment of the sugar content of intact fruit , 2000 .

[18]  E. Moltó,et al.  Calibration transfer between NIR diode array and FT-NIR spectrophotometers for measuring the soluble solids contents of apple , 2007 .

[19]  Using Clutter to Improve Pattern Recognition, Calibration and Classification Models , 2010 .

[20]  Sumio Kawano,et al.  Development of a Common Calibration Model for Determining the Brix Value of Intact Apple, Pear and Persimmon Fruits by near Infrared Spectroscopy , 2014 .

[21]  D. Himmelsbach,et al.  Effect of Random Noise on the Performance of NIR Calibrations , 1998 .