A theoretical study on phase-contrast mammography with Thomson-scattering x-ray sources.

PURPOSE The x-ray transmitted beam from any material/tissue depends on the complex refractive index (n= 1-delta+ibeta), where delta is responsible for the phase shift and beta is for the beam attenuation. Although for human tissues, the delta cross section is about 1000 times greater than the beta ones in the x-ray energy range from 10 to 150 keV, the gain in breast tumor visualization of phase-contrast mammography (PCM) with respect to absorption contact imaging (AI) is limited by the maximum dose that can be delivered to the patient. Moreover, in-line PC imaging (PCI) is the simplest experimental mode among all available x-ray PCI techniques since no optics are needed. The latter is a fundamental requirement in order to transfer the results of laboratory research into hospitals. Alternative to synchrotron radiation sources, the implementation of relativistic Thomson-scattering (TS) x-ray sources is particularly suitable for hospital use because of their high peak brightness within a relatively compact and affordable system. In this work, the possibility to realize PCM using a TS source in a hospital environment is studied, accounting for the effect of a finite deliverable dose on the PC visibility enhancement with respect to AI. METHODS The contrast-to-noise ratio of tumor-tissue lesions in PCM has been studied on the bases of a recent theoretical model, describing image contrast formation by means of both wave-optical theory and the mutual coherence formalism. The latter is used to describe the evolution, during wave propagation, of the coherence of the wave field emitted by a TS source. The contrast-to-noise ratio for both PCI and AI has been analyzed in terms of tumor size, beam energy, detector, and source distances, studying optimal conditions for performing PCM. Regarding other relevant factors which could influence "tumor" visibility, the authors have assumed simplified conditions such as a spherical shape description of the tumor inclusion, a constant surrounding background, ideal conditions for the calculus of the contrast-to-noise ratio. RESULTS The results show the possibility to enhance with PCI the signal-to-noise ratio for features in the submillimeter scale. This finding could give PCM a great advantage with respect to AI, opening the possibility to decrease the number of wrong diagnoses before histological exams. The results agree with experimental evidences obtained by Dreossi et al. [D. Dreossi et al., "The mammography project at the SYRMEP beamline," Eur. J. Radiol. 68, S58-S62 (2008)] with real PCM using synchrotron radiation. CONCLUSIONS The challenging characteristics of TS sources, suitable for PCM, should be fluxes of at least 10(11) photons/s emitted by very small sources of about 10 microm, together with moderate energy spreads (less than 10%) in order to realize both sufficient spatial coherence and enough fluence on the patient, collecting images in reasonable exposure times. These fluxes will be achieved by next generation TS sources which are already under development.

[1]  B. Thomlinson Medical Applications of Synchrotron Radiation , 1991, Physics in medicine and biology.

[2]  M. Ando,et al.  First Observation of Small Fractures on a Human Dried Proximal Phalanx by Synchrotron X-Ray Interference Radiography , 1999 .

[3]  D. H. Lee,et al.  Phase contrast radiography of Lewy bodies in Parkinson disease , 2006, NeuroImage.

[4]  M. Ferrario,et al.  Linear and Nonlinear Thomson Scattering for Advanced X-ray Sources in PLASMONX , 2008, IEEE Transactions on Plasma Science.

[5]  A. Snigirev,et al.  On the possibilities of x-ray phase contrast microimaging by coherent high-energy synchrotron radiation , 1995 .

[6]  A Bravin,et al.  High-resolution brain tumor visualization using three-dimensional x-ray phase contrast tomography , 2007, Physics in medicine and biology.

[7]  Albert Rose,et al.  A Unified Approach to the Performance of Photographic Film, Television Pickup Tubes, and the Human Eye * --> , 1946 .

[8]  V. N. Ingal,et al.  Phase mammography--a new technique for breast investigation. , 1998, Physics in medicine and biology.

[9]  W. R. Fowkes,et al.  Development of an X‐band RF Gun at SLAC , 2002 .

[10]  Hong Liu,et al.  Clarification of aspects in in-line phase-sensitive x-ray imaging. , 2007, Medical physics.

[11]  Alberto Bravin,et al.  High-resolution CT by diffraction-enhanced x-ray imaging: mapping of breast tissue samples and comparison with their histo-pathology , 2007, Physics in medicine and biology.

[12]  E Castelli,et al.  The mammography project at the SYRMEP beamline. , 2008, European journal of radiology.

[13]  M. Carpinelli,et al.  Phase contrast imaging simulation and measurements using polychromatic sources with small source-object distances , 2008 .

[14]  R. Lewis,et al.  Medical phase contrast x-ray imaging: current status and future prospects. , 2004, Physics in medicine and biology.

[15]  S. Wilkins,et al.  Phase-contrast imaging using polychromatic hard X-rays , 1996, Nature.

[16]  Yakov I Nesterets,et al.  Some simple rules for contrast, signal-to-noise and resolution in in-line x-ray phase-contrast imaging. , 2008, Optics express.

[17]  M. Ragozzino Optimal photon energies with respect to absorbed dose for visualization of soft tissue masses with adipose tissue. , 1982, Medical physics.

[18]  J. S. Laughlin,et al.  Absorbed radiation dose in mammography. , 1979, Radiology.

[19]  A. Giulietti,et al.  Thomson backscattering X-rays from ultra-relativistic electron bunches and temporally shaped laser pulses , 2005 .

[20]  Hong Liu,et al.  Phase-space formulation for phase-contrast x-ray imaging. , 2005, Applied optics.

[21]  David R. Dance,et al.  Breast cancer diagnosis using scattered X‐rays , 2000 .

[22]  T Takeda,et al.  Blood vessels: depiction at phase-contrast X-ray imaging without contrast agents in the mouse and rat-feasibility study. , 2000, Radiology.

[23]  Frederic V. Hartemann,et al.  Three-dimensional time and frequency-domain theory of femtosecond x-ray pulse generation through Thomson scattering , 2004 .

[24]  Stefano Lagomarsino,et al.  In-line phase-contrast imaging for strong absorbing objects. , 2008, Physics in medicine and biology.

[25]  J. Kuba,et al.  Experimental characterization of an ultra-fast Thomson scattering x-ray source with three-dimensional time and frequency-domain analysis , 2004 .

[26]  Xizeng Wu,et al.  A general theoretical formalism for X-ray phase contrast imaging. , 2003, Journal of X-ray science and technology.

[27]  D. Babot,et al.  New developments in simulating X-ray phase contrast imaging , 2007 .

[28]  Hong Liu,et al.  Clinical implementation of x-ray phase-contrast imaging: theoretical foundations and design considerations. , 2003, Medical physics.

[29]  David N. Fittinghoff,et al.  PLEIADES: A picosecond Compton scattering x-ray source for advanced backlighting and time-resolved material studies , 2004 .

[30]  S. Fiedler,et al.  Imaging lobular breast carcinoma: comparison of synchrotron radiation DEI-CT technique with clinical CT, mammography and histology. , 2004, Physics in medicine and biology.

[31]  P. Cloetens,et al.  Quantitative comparison between two phase contrast techniques: diffraction enhanced imaging and phase propagation imaging , 2006, Physics in medicine and biology.

[32]  Franz Pfeiffer,et al.  Hard X-ray phase-contrast imaging with the Compact Light Source based on inverse Compton X-rays. , 2009, Journal of synchrotron radiation.

[33]  A. Dinklage,et al.  Thomson scattering analysis with the Bayesian probability theory , 2002 .

[34]  S. Marchesini,et al.  Spatial coherence of synchrotron radiation , 1995 .

[35]  E. Pisano,et al.  Human breast cancer specimens: diffraction-enhanced imaging with histologic correlation--improved conspicuity of lesion detail compared with digital radiography. , 2000, Radiology.

[36]  J. Urakawa,et al.  Development of high-brightness laser synchrotron source at BNL ATF , 2001 .

[37]  A. Peterzol,et al.  X-ray phase contrast image simulation , 2007 .

[38]  K. Dobashi,et al.  Observation of high-intensity X-rays in inverse Compton scattering experiment , 2000 .

[39]  E Castelli,et al.  Mammography with synchrotron radiation: phase-detection techniques. , 2000, Radiology.

[40]  R. Geise,et al.  Composition of mammographic phantom materials. , 1996, Radiology.

[41]  Kentaro Uesugi,et al.  X-ray refraction-enhanced imaging and a method for phase retrieval for a simple object. , 2002, Journal of synchrotron radiation.

[42]  A. Gibaud,et al.  Effects of partial coherence on the scattering of x rays by matter , 1998 .