Standardisation of a European measurement method for the determination of total gaseous mercury: results of the field trial campaign and determination of a measurement uncertainty and working range.
暂无分享,去创建一个
Working Group 25 of the European Committee for Standardisation's (CEN) Technical Committee 264 'Air Quality' is currently finalising a standard method for the measurement of total gaseous mercury (TGM) in ambient air, in response to the requirements of the European Union's Fourth Air Quality Daughter Directive (4(th) DD). We report the results of a programme of field measurements and the statistical analysis performed to assess the uncertainty of the proposed standard method, define its working range and determine its compliance with the required data quality objectives of the Fourth Air Quality Daughter Directive. The statistical analysis has shown that the maximum relative expanded uncertainty of 50% allowed by the 4(th) DD is met down to a mercury mass concentration of approximately 0.75 ng m(-3), and that the dominant contribution to this uncertainty is systematic bias between instruments, mainly arising from the uncertainty in the calibration of the instruments.
[1] J. Miller,et al. Statistics and chemometrics for analytical chemistry , 2005 .
[2] A. Brown,et al. Accurate calibration of mercury vapour measurements. , 2008, The Analyst.
[3] W. Corns,et al. A practical uncertainty budget for ambient mercury vapour measurement , 2008 .