Estimation of displacement vectors and strain tensors in elastography using angular insonifications

In current practice, only one out of three components of the tissue displacement vector and one of nine components of the strain tensor are accurately estimated and imaged in ultrasound elastography. Since, only the axial component of both the displacement and strain are imaged, other important elastic parameters, such as shear strains and the Poisson's ratio, also are not imaged. Moreover, reconstruction of the Young's modulus would be significantly improved if all components of the strain tensor were available. In this paper, we describe a new method for estimating all the components of the tissue displacement vector following a quasi-static compression. The method uses displacements estimated from radiofrequency echo-signals along multiple ultrasound beam insonification directions. At each spatial location in the compressed medium, orthogonal tissue displacements in both the axial and lateral direction with respect to the direction of the applied compression are estimated by curve fitting angular displacement vector data calculated for all insonification directions. Following displacement estimation in orthogonal directions, components of the corresponding normal and shear strain tensors are estimated. Simulation and experimental results demonstrate the utility of this technique for the computation of the normal and shear strain tensors.

[1]  J. Ophir,et al.  Elastography: A Quantitative Method for Imaging the Elasticity of Biological Tissues , 1991, Ultrasonic imaging.

[2]  J Ophir,et al.  Shear strain estimation and lesion mobility assessment in elastography. , 2000, Ultrasonics.

[3]  C. S. Spalding,et al.  In vivo real-time freehand palpation imaging. , 2003, Ultrasound in medicine & biology.

[4]  J F Greenleaf,et al.  Application of Radiation Force in Noncontact Measurement of the Elastic Parameters , 1999, Ultrasonic imaging.

[5]  Tomy Varghese,et al.  Wavelet denoising of displacement estimates in elastography. , 2004, Ultrasound in medicine & biology.

[6]  K J Parker,et al.  Tissue response to mechanical vibrations for "sonoelasticity imaging". , 1990, Ultrasound in medicine & biology.

[7]  G. Mailloux,et al.  Computer Analysis of Heart Motion from Two-Dimensional Echocardiograms , 1987, IEEE Transactions on Biomedical Engineering.

[8]  O. Bonnefous Measurement of the complete (3D) velocity vector of blood flows , 1988, IEEE 1988 Ultrasonics Symposium Proceedings..

[9]  Gregg E. Trahey,et al.  A Finite Element Model of Remote Palpation of Breast Lesions Using Radiation Force: Factors Affecting Tissue Displacement , 2000, Ultrasonic imaging.

[10]  F. Kallel,et al.  A Least-Squares Strain Estimator for Elastography , 1997, Ultrasonic imaging.

[11]  B. Garra,et al.  Elastography of breast lesions: initial clinical results. , 1997, Radiology.

[12]  S. Emelianov,et al.  Shear wave elasticity imaging: a new ultrasonic technology of medical diagnostics. , 1998, Ultrasound in medicine & biology.

[13]  W F Walker,et al.  Internal deformation of a uniform elastic solid by acoustic radiation force. , 1999, The Journal of the Acoustical Society of America.

[14]  K. R. Raghavan,et al.  Lateral displacement estimation using tissue incompressibility , 1996, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[15]  T. Krouskop,et al.  Poroelastography: imaging the poroelastic properties of tissues. , 2001, Ultrasound in medicine & biology.

[16]  F. Kallel,et al.  Tradeoffs in Elastographic Imaging , 2001, Ultrasonic imaging.

[17]  J. Ophir,et al.  A new elastographic method for estimation and imaging of lateral displacements, lateral strains, corrected axial strains and Poisson's ratios in tissues. , 1998, Ultrasound in medicine & biology.

[18]  Jonathan Ophir,et al.  Axial resolution in elastography. , 2002, Ultrasound in medicine & biology.

[19]  Insana,et al.  Maximum-likelihood approach to strain imaging using ultrasound , 2000, The Journal of the Acoustical Society of America.

[20]  J. Ophir,et al.  Three-dimensional tissue motion and its effect on image noise in elastography , 1997, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[21]  J Ophir,et al.  Fundamental limitations on the contrast-transfer efficiency in elastography: an analytic study. , 1996, Ultrasound in medicine & biology.

[22]  G E Trahey,et al.  A real time system for quantifying and displaying two-dimensional velocities using ultrasound. , 1993, Ultrasound in medicine & biology.

[23]  F. S. Vinson,et al.  A pulsed Doppler ultrasonic system for making noninvasive measurements of the mechanical properties of soft tissue. , 1987, Journal of rehabilitation research and development.

[24]  B A Porter,et al.  Real-time spatial compound imaging: application to breast, vascular, and musculoskeletal ultrasound. , 2001, Seminars in ultrasound, CT, and MR.

[25]  Yadong Li,et al.  A frequency domain model for generating B-mode images with array transducers , 1999, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[26]  M. Fink,et al.  Ultrafast compound imaging for 2-D motion vector estimation: application to transient elastography , 2002, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[27]  A.A. Morsy,et al.  FLASH correlation: a new method for 3-D ultrasound tissue motion tracking and blood velocity estimation , 1999, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[28]  Faouzi Kallel,et al.  Tissue elasticity reconstruction using linear perturbation method , 1996, IEEE Trans. Medical Imaging.

[29]  Jeffrey A Ketterling,et al.  Time-domain pressure response of arrays with periodic excitation. , 2003, The Journal of the Acoustical Society of America.

[30]  B. J. Geiman,et al.  2-D motion estimation using two parallel receive beams , 2001, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[31]  A. Quazi An overview on the time delay estimate in active and passive systems for target localization , 1981 .

[32]  E B Hunziker,et al.  Mechanical anisotropy of the human knee articular cartilage in compression , 2003, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[33]  M. Sato [Mechanical properties of living tissues]. , 1986, Iyo denshi to seitai kogaku. Japanese journal of medical electronics and biological engineering.

[34]  M. O’Donnell,et al.  Internal displacement and strain imaging using ultrasonic speckle tracking , 1994, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.