Knowledge of the spatial and temporal distribution of atmospheric carbon dioxide (CO2) is important for understanding the carbon natural cycle, predicting its future levels and its impact on global warming and climate changes. Laser technology has advanced considerably during the past few years in the 2-micron region where strong optimum lines are available for measuring CO2 using the Differential Absorption Lidar (DIAL) technique. Although several types of detectors might be suitable for this particular wavelength, an ideal device would have high gain, low noise and narrow spectral response peaking around the wavelength of interest. This increases the signal-to-noise ratio and minimizes the background signal, thereby increasing the instrument sensitivity and dynamic range. In this paper the detector requirements for a long range CO2 DIAL measurement will be presented. The requirements were compared to commercially available and newly developed infrared (IR) detectors. The IR detectors considered for this study consist of the well developed InGaAs and HgCdTe p-n junction photodiodes, beside the newly developed and proposed InGaAsSb and InGaSb detectors. All of the detectors were characterized and their performances were compared with the CO2 DIAL detector requirements. The characterization experiments included spectral response, dark current and noise measurements. CO2 DIAL measurements using InGaAs detectors were attempted and indicated the need for better detector performance. While InGaAs detectors showed the closest performance to the instrument requirements, InGaSb detectors indicated a promising solution.
[1]
G. G. Stokes.
"J."
,
1890,
The New Yale Book of Quotations.
[2]
Tamer F. Refaat,et al.
InGaSb ternary material for 2 m detectors
,
2003,
Conference on Lasers and Electro-Optics, 2003. CLEO '03..
[3]
Aaas News,et al.
Book Reviews
,
1893,
Buffalo Medical and Surgical Journal.
[4]
Ronald J. Gutmann,et al.
Antimonide-based devices for thermophotovoltaic applications
,
1999
.
[5]
Carl Ekdahl,et al.
Atmospheric carbon dioxide variations at Mauna Loa Observatory, Hawaii
,
1976
.
[6]
Tamer F. Refaat,et al.
InGaAsSb Detectors' Characterization for CO 2 Lidar/DIAL Applications
,
2003
.
[7]
Laurence S. Rothman,et al.
The HITRAN molecular spectroscopic database and HAWKS (HITRAN atmospheric workstation)
,
1998,
Defense, Security, and Sensing.
[8]
Michael G. Mauk,et al.
GaInAsSb and InAsSbP photodetectors for mid-infrared wavelengths
,
1997,
Photonics West.
[9]
Upendra N. Singh,et al.
Injection-seeded, room-temperature, diode-pumped Ho:Tm:YLF laser with output energy of 600 mJ at 10 Hz
,
1998
.
[10]
George P. Eppeldauer,et al.
Spectroradiometric Detector Measurements: Part III--Infrared Detectors
,
1998
.