Measurement of Blood flow through Av-Fistulae by Means of Doppler Sonography in Regularly Haemodialysed Patients

In regularly dialyzed patients a variety of pathological events can negatively influence haemodynamics and blood flow through arteriovenous fistula, leading to inadequate blood flow through the dialyzer or disturbances in hemodynamics of the whole body. It therefore appears important to quantify flow velocity and volume flow through the arteriovenous fistula in such cases. We used a Vasoview computer controlled system for noninvasive vascular diagnostics based on B-scan “real-time” ultrasound for imaging the structure of tissue, combined with pulsed Doppler ultrasound for determination of hemodynamics. Thirty patients (16 males and 14 females, aged 45 ± 10 years; range 23 to 61 years), with different periods spent on hemodialysis (5.5 ± 3.1 years, range 1 to 11 years) were included in this study. The average systolic, diastolic and mean blood volume flows were 2131.8 ± 565.8, 972.0 ± 309.6 and 728.4 ± 287.4 ml/min, respectively. The mean blood volume flow was calculated by integration of the area under curve of blood flow in one heart cycle on the Doppler signal. It is calculated by the apparatus and displayed on the screen during measurement. The average blood vessel diameter was 9.1 ± 1.3 mm (μ ± σ). The results revealed a marked inter-individual variation in volume flow through arteriovenous fistulae of dialyzed uremics (range 240.0 to 1200.0 ml/min). Doppler ultrasound thus appears to be a valuable method for determination of blood flow through arteriovenous fistula of dialyzed uremics as well as for detection of hemodynamics disturbances of interest, such as turbulent blood flow.

[1]  W. Kramer,et al.  Short-Term Dialysis - Long-Term Complications , 1987 .

[2]  J. McGahan,et al.  Absolute flow measurements using pulsed Doppler US. Work in progress. , 1986, Radiology.

[3]  D. Silver,et al.  Transcutaneous Quantitation of Arterial Flow with Ultrasound , 1982, Annals of surgery.

[4]  L. Forsberg,et al.  Quantitative Doppler and Ultrasound Measurements in Surgically Performed Arteriovenous Fistulas of the Arm , 1980, Acta radiologica: diagnosis.

[5]  D J Phillips,et al.  Carotid Artery Velocity Patterns in Normal and Stenotic Vessels , 1980, Stroke.

[6]  E. Lichti,et al.  Applications of the Doppler , 1975, Angiology.

[7]  Lichti El,et al.  Applications of the Doppler: Common and unusual situations. , 1975 .

[8]  C. Ronco,et al.  High-flux haemodialysis with 1.5 m2 modified cuprammonium rayon membrane: technical and clinical evaluation. , 1988, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[9]  W. Kramer,et al.  Short-term dialysis--long-term complications. Ten years experience with short-duration renal replacement therapy. , 1987, Blood purification.

[10]  M. Ramos Boyero,et al.  Flow of dialysis fistulas. Noninvasive study performed with standard Doppler equipment. , 1985, Nephron.

[11]  L. Pourcelot,et al.  Doppler spectrum analysis and vascular imaging in the diagnosis of extracranial carotid artery disease. , 1985, International angiology : a journal of the International Union of Angiology.

[12]  M. R. Boyero,et al.  Flow of Dialysis Fistulas , 1985 .

[13]  J. Shinaberger,et al.  Technical aspects of high-flux hemodiafiltration for adequate short (under 2 hours) treatment. , 1984, Transactions - American Society for Artificial Internal Organs.

[14]  A. Hart,et al.  Clinical significance of intraoperative flow measurement during bovine heterograft AV fistulae formation. , 1981, Transactions - American Society for Artificial Internal Organs.