Power quality signals detection using S-transform

Power quality has become very important issue over the last decade. Poor quality can cause equipment failure, data and economical. An automated monitoring system is needed to ensure signal quality, reduces diagnostic time and rectifies failures. In this paper, S-transform is used to analyze the power quality signals such as swell, sag, interruption, harmonic, interharmonic and transient based on IEEE Std. 1159-2009 to detect, localize and classify the disturbance. The S-transform is used to represent the signals in time-frequency representation (TFR).). To get an accurate TFR, the parameters are estimated to identify the signal characteristics. The signal characteristics are the root means square voltage (Vrms), total harmonic distortion (THD), total non harmonic distortion (TnHD) and total waveform distortion (TWD). To verify the performance of S-transform several sets of data with different time duration are analyzed to determine the accuracy of S-transform. The lowest value of mean absolute percentage error (MAPE) gives the highest accuracy to provide the best performance of TFD.

[1]  Abdul Rahim Abdullah,et al.  Power Quality Analysis Using Bilinear Time-Frequency Distributions , 2011 .

[2]  Abdul Rahim Abdullah,et al.  Bilinear time-frequency analysis techniques for power quality signals , 2012, IMECS 2012.

[3]  Lalu Mansinha,et al.  Localization of the complex spectrum: the S transform , 1996, IEEE Trans. Signal Process..

[4]  A.R. Abdullah,et al.  Power quality analysis using linear time-frequency distribution , 2008, 2008 IEEE 2nd International Power and Energy Conference.

[5]  Tadeusz Lobos,et al.  Analysis of non‐stationary electric signals using the S‐transform , 2009 .

[6]  Irene Yu-Hua Gu,et al.  Signal processing of power quality disturbances , 2006 .

[7]  N. Saad,et al.  Power quality analysis using spectrogram and gabor transformation , 2007, 2007 Asia-Pacific Conference on Applied Electromagnetics.

[8]  Pradipta Kishore Dash,et al.  S-transform-based intelligent system for classification of power quality disturbance signals , 2003, IEEE Trans. Ind. Electron..

[9]  Yu-Hsiang Wang,et al.  The Tutorial : S Transform , 2010 .

[10]  A.Z. Sha'ameri,et al.  Detection and Classification of Power Quality Disturbances Using Time-Frequency Analysis Technique , 2007, 2007 5th Student Conference on Research and Development.

[11]  Abdul Rahim Bin Abdullah,et al.  Classification of power quality signals using smooth-windowed Wigner-Ville distribution , 2010, 2010 International Conference on Electrical Machines and Systems.

[12]  Robert Glenn Stockwell,et al.  A basis for efficient representation of the S-transform , 2007, Digit. Signal Process..

[13]  Zhang Shi,et al.  The research of power quality analysis based on improved S-Transform , 2009, 2009 9th International Conference on Electronic Measurement & Instruments.

[14]  C. Robert Pinnegar,et al.  The S-transform with windows of arbitrary and varying shape , 2003 .

[15]  Ronald L. Allen,et al.  Signal Analysis: Time, Frequency, Scale and Structure , 2003 .