Coupled human erythrocyte velocity field and aggregation measurements at physiological haematocrit levels.

Simultaneous measurement of erythrocyte (RBC) velocity fields and aggregation properties has been successfully performed using an optical shearing microscope and Particle Image Velocimetry (PIV). Blood at 45% haematocrit was sheared at rates of 5.4< or =gamma < or = 252 s(-1) and imaged using a high speed camera. The images were then processed to yield aggregation indices and flow velocities. Negligible levels of aggregation were observed for gamma > or = 54.0 s(-1), while high levels of aggregation and network formation occurred for gamma < or = 11.7 s(-1). The results illustrate that the velocity measurements are dependent on the extent of RBC aggregation. High levels of network formation cause the velocities at gamma > or = 5.4 s(-1) to deviate markedly from the expected solid body rotation profile. The effect of aggregation level on the PIV accuracy was assessed by monitoring the two-dimensional (2D) correlation coefficients. Lower levels of aggregation result in poorer image correlation, from which it can be inferred that PIV accuracy is reduced. Moreover, aggregation is time-dependent, and consequently PIV accuracy may decrease during recording as the cells break up. It is therefore recommended that aggregation and its effects are taken into account in future when undertaking blood flow studies using PIV. The simplicity of the technique, which requires no lasers, filters, or special pretreatments, demonstrates the potential wide-spread applicability of the data acquisition system for accurate blood flow PIV and aggregation measurement.

[1]  Gabriel Acevedo-Bolton,et al.  Intracardiac fluid forces are an essential epigenetic factor for embryonic cardiogenesis , 2003, Nature.

[2]  Sang Joon Lee,et al.  Micro-PIV measurements of blood flow in extraembryonic blood vessels of chicken embryos , 2007, Physiological measurement.

[3]  M W Rampling,et al.  Influence of cell-specific factors on red blood cell aggregation. , 2004, Biorheology.

[4]  Y. Sugii,et al.  In vivo PIV measurement of red blood cell velocity field in microvessels considering mesentery motion. , 2002, Physiological measurement.

[5]  H Schmid-Schönbein,et al.  On the shear rate dependence of red cell aggregation in vitro. , 1968, The Journal of clinical investigation.

[6]  Andreas Fouras,et al.  Three-dimensional synchrotron x-ray particle image velocimetry , 2007 .

[7]  S. Wereley,et al.  A PIV Algorithm for Estimating Time-Averaged Velocity Fields , 2000 .

[8]  H. Meiselman,et al.  Dielectric approach to investigation of erythrocyte aggregation. II. Kinetics of erythrocyte aggregation-disaggregation in quiescent and flowing blood. , 2000, Biorheology.

[9]  S Chien,et al.  Ultrastructural basis of the mechanism of rouleaux formation. , 1973, Microvascular research.

[10]  M. Woodward,et al.  Does sticky blood predict a sticky end? Associations of blood viscosity, haematocrit and fibrinogen with mortality in the West of Scotland , 2003, British journal of haematology.

[11]  E. Kaliviotis,et al.  On the effect of dynamic flow conditions on blood microstructure investigated with optical shearing microscopy and rheometry , 2007, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[12]  E. Kaliviotis,et al.  On the effect of microstructural changes of blood on energy dissipation in Couette flow. , 2008, Clinical hemorheology and microcirculation.

[13]  Henrik Bruus,et al.  Micro particle-image velocimetry of bead suspensions and blood flows , 2005 .

[14]  J. Westerweel,et al.  Single-pixel resolution ensemble correlation for micro-PIV applications , 2004 .

[15]  Jerry Westerweel,et al.  In vivo micro particle image velocimetry measurements of blood-plasma in the embryonic avian heart. , 2006, Journal of biomechanics.

[16]  R. Lima,et al.  Confocal micro-PIV measurements of three-dimensional profiles of cell suspension flow in a square microchannel , 2006 .

[17]  P. S. Ramalho Microcirculation and hemorheology. , 1983, Acta medica portuguesa.

[18]  D. Beebe,et al.  A particle image velocimetry system for microfluidics , 1998 .

[19]  Markus Raffel,et al.  Particle Image Velocimetry: A Practical Guide , 2002 .

[20]  Yohsuke Imai,et al.  Radial dispersion of red blood cells in blood flowing through glass capillaries: the role of hematocrit and geometry. , 2008, Journal of biomechanics.

[21]  E. Kaliviotis,et al.  Fast response characteristics of red blood cell aggregation. , 2008, Biorheology.

[22]  Shigeo Wada,et al.  In vitro confocal micro-PIV measurements of blood flow in a square microchannel: the effect of the haematocrit on instantaneous velocity profiles. , 2007, Journal of biomechanics.

[23]  Piero Tortoli,et al.  Toward a better quantitative measurement of aortic flow. , 2002, Ultrasound in medicine & biology.

[24]  Sang Joon Lee,et al.  Synchrotron microimaging technique for measuring the velocity fields of real blood flows , 2005 .