Exergy based analysis of solar air heater having discrete V-down rib roughness on absorber plate

The artificially rib roughened solar air heaters perform thermally better than the conventional flat-plate solar air heater under same operating conditions. However, the artificial rib roughness leads to higher friction factor thereby increasing pumping power. The second law based exergy analysis is suitable for design of rib roughened solar air heaters as it incorporates quality of useful energy output and pumping power. The exergetic efficiency of a solar air heater having discrete V-down rib roughness is studied analytically and the results obtained are compared with that of a conventional flat-plate solar air heater. Flow Reynolds number and rib-roughness parameters, viz., relative roughness pitch, relative gap position, relative gap width, angle of attack and relative roughness height have combined effect on heat transfer as well as fluid friction. The exergy based criterion suggests use of the discrete V-down rib roughened solar air heater for the Reynolds number range normally used in solar air heaters. It was found that there exist optimum roughness parameters of the discrete V-down rib for a given Reynolds number (or temperature rise parameter) at which the exergetic efficiency is highest. Curves of optimum rib-roughness parameters are also plotted.

[1]  Mehmet Esen,et al.  Experimental investigation of thermal performance of a double-flow solar air heater having aluminium cans , 2009 .

[2]  K. Altfeld,et al.  Second law optimization of flat-plate solar air heaters Part I: The concept of net exergy flow and the modeling of solar air heaters , 1988 .

[3]  Sei-Young Lee,et al.  The Effects of Gap Position in Discrete Ribs on Local Heat/Mass Transfer in a Square Duct , 2003 .

[4]  J. Saini,et al.  Heat transfer and friction characteristics of solar air heater ducts having integral inclined discrete ribs on absorber plate , 2009 .

[5]  Kamil Kaygusuz,et al.  Exergy analysis of solar-assisted heat-pump systems for domestic heating , 1993 .

[6]  Frank P. Incropera,et al.  Fundamentals of Heat and Mass Transfer , 1981 .

[7]  R. Karwa,et al.  Performance evaluation of solar air heaters having v-down discrete rib roughness on the absorber plate , 2010 .

[8]  S. C. Kaushik,et al.  Exergetic performance evaluation and parametric studies of solar air heater , 2008 .

[9]  S. C. Solanki,et al.  Heat transfer and friction in solar air heater duct with V-shaped rib roughness on absorber plate , 2002 .

[10]  Abdulkadir Sengür,et al.  Modelling of a new solar air heater through least-squares support vector machines , 2009, Expert Syst. Appl..

[11]  Abdulkadir Sengür,et al.  Artificial neural network and wavelet neural network approaches for modelling of a solar air heater , 2009, Expert Syst. Appl..

[12]  H. Öztürk,et al.  Exergy‐based performance analysis of packed‐bed solar air heaters , 2004 .

[13]  S. C. Solanki,et al.  Thermo-hydraulic performance of solar air heaters having integral chamfered rib roughness on absorber plates , 2001 .

[14]  A. Midilli,et al.  Energy and exergy analyses of solar drying process of pistachio , 2003 .

[15]  R. P. Saini,et al.  Performance of artificially roughened solar air heaters—A review , 2009 .

[16]  Aydın Durmuş,et al.  Energy and exergy analyses of thin layer drying of mulberry in a forced solar dryer , 2010 .

[17]  Hikmet Esen,et al.  Experimental energy and exergy analysis of a double-flow solar air heater having different obstacles on absorber plates , 2008 .

[18]  S. Chander,et al.  Heat transfer and friction factor correlations of solar air heater ducts artificially roughened with discrete V-down ribs , 2011 .

[19]  S. Mullick,et al.  Heat transfer characteristics of a solar air heater used for drying purposes , 1983 .

[20]  S. C. Kaushik,et al.  Performance evaluation of solar air heater having expanded metal mesh as artificial roughness on absorber plate , 2009 .

[21]  S. C. Kaushik,et al.  Performance evaluation of solar air heater for various artificial roughness geometries based on energy, effective and exergy efficiencies , 2009 .

[22]  Noam Lior,et al.  Energy, exergy, and Second Law performance criteria , 2007 .

[23]  Amir Rahimi,et al.  Energy and exergy analysis of an indirect solar cabinet dryer based on mathematical modeling results , 2011 .

[24]  M. Picon Nunez,et al.  Exergy analysis and optimization of a solar-assisted heat pump , 1998 .

[25]  R. Karwa EXPERIMENTAL STUDIES OF AUGMENTED HEAT TRANSFER AND FRICTION IN ASYMMETRICALLY HEATED RECTANGULAR DUCTS WITH RIBS ON THE HEATED WALL IN TRANSVERSE, INCLINED, V-CONTINUOUS AND V-DISCRETE PATTERN , 2003 .

[26]  R. Shah,et al.  Handbook of single-phase convective heat transfer , 1987 .

[27]  S. C. Solanki,et al.  Second law optimization of a solar air heater having chamfered rib–groove roughness on absorber plate , 2007 .

[28]  Aydın Durmuş,et al.  Efficiency and exergy analysis of a new solar air heater , 2004 .

[29]  A. Uçar,et al.  Thermal and exergy analysis of solar air collectors with passive augmentation techniques , 2006 .

[30]  A. Bejan Advanced Engineering Thermodynamics , 1988 .

[31]  S. J. Kline,et al.  Describing Uncertainties in Single-Sample Experiments , 1953 .

[32]  B. N. Prasad,et al.  Effect of artificial roughness on heat transfer and friction factor in a solar air heater , 1988 .

[33]  S. C. Mullick,et al.  Approximate method for computation of glass cover temperature and top heat-loss coefficient of solar collectors with single glazing , 1999 .