Internal loads in the human tibia during gait.

BACKGROUND Internal loads in long bones are of special interest, for testing and optimization of current implant designs for fracture treatment. Inverse dynamic musculoskeletal models were successfully used to determine the muscle forces in the lower extremities, however the internal loads expressed as forces and moments along the human tibia during gait have not been reported. METHODS A musculoskeletal model of the lower extremities, developed and provided under public domain from the AnyBody research group (www.anybody.aau.dk), was modified to determine the three-dimensional internal loads along the tibial axis during gait. To corroborate this numerical model, the calculated resultant hip contact force as well as the axial force on the tibial plateau were compared to in vivo data from the literature. FINDINGS The highest internal loads were the axial force with up to 4.7 bodyweight and the bending moment in the sagittal plane with up to 71.6 bodyweight times millimetre in the late stance phase. The extreme values of the internal loads along the tibial axis varied up to 1.5 bodyweight and 85.7 bodyweight times millimetre. In the distal part of the tibia, the axial force dominated the three-dimensional internal load case, whereas the internal moments became more significant with increasing distance from the ankle joint. INTERPRETATION This study provides for the first time the three-dimensional internal loads, expressed as forces and moments along the human tibia during normal gait. The results of this study could be used to improve the mechanical behaviour of current implant designs for the treatment of tibial fractures to avoid implant failures under in vivo loading conditions.

[1]  P. Walker,et al.  Forces and moments telemetered from two distal femoral replacements during various activities. , 2001, Journal of biomechanics.

[2]  E. Schneider,et al.  Influence of muscle forces on femoral strain distribution. , 1998, Journal of biomechanics.

[3]  R. Brand,et al.  Comparison of hip force calculations and measurements in the same patient. , 1994, The Journal of arthroplasty.

[4]  B. Prilutsky,et al.  Sensitivity of predicted muscle forces to parameters of the optimization-based human leg model revealed by analytical and numerical analyses. , 2001, Journal of biomechanics.

[5]  D. D’Lima,et al.  THE CHITRANJAN RANAWAT AWARD: In Vivo Knee Forces after Total Knee Arthroplasty , 2005, Clinical orthopaedics and related research.

[6]  G Bergmann,et al.  Direct comparison of calculated hip joint contact forces with those measured using instrumented implants. An evaluation of a three-dimensional mathematical model of the lower limb. , 2003, Journal of biomechanics.

[7]  E Schneider,et al.  Loads acting in an intramedullary nail during fracture healing in the human femur. , 2001, Journal of biomechanics.

[8]  G. Bergmann,et al.  Musculo-skeletal loading conditions at the hip during walking and stair climbing. , 2001, Journal of biomechanics.

[9]  Christopher L. Vaughan,et al.  Dynamics of human gait , 1992 .

[10]  W Baumann,et al.  The three-dimensional determination of internal loads in the lower extremity. , 1997, Journal of biomechanics.

[11]  P S Walker,et al.  Influence of muscle activity on the forces in the femur: an in vivo study. , 1997, Journal of biomechanics.

[12]  G. Bergmann,et al.  Hip joint loading during walking and running, measured in two patients. , 1993, Journal of biomechanics.

[13]  H. Hatze The fundamental problem of myoskeletal inverse dynamics and its implications. , 2002, Journal of biomechanics.

[14]  K Seide,et al.  Three-dimensional load measurements in an external fixator. , 2004, Journal of biomechanics.

[15]  M. Damsgaard,et al.  Muscle recruitment by the min/max criterion -- a comparative numerical study. , 2001, Journal of biomechanics.

[16]  William R Taylor,et al.  Tibio‐femoral loading during human gait and stair climbing , 2004, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[17]  J. O'Connor,et al.  Validation of a lower limb model with in vivo femoral forces telemetered from two subjects. , 1997, Journal of biomechanics.

[18]  R. Nanda,et al.  Biomechanical testing of the locking compression plate: when does the distance between bone and implant significantly reduce construct stability? , 2007, Injury.

[19]  M. Kuster,et al.  Biomechanical Considerations in Plate Osteosynthesis: The Effect of Plate-to-Bone Compression With and Without Angular Screw Stability , 2007, Journal of orthopaedic trauma.

[20]  G. Bergmann,et al.  Hip contact forces and gait patterns from routine activities. , 2001, Journal of biomechanics.

[21]  D T Davy,et al.  Telemetric force measurements across the hip after total arthroplasty. , 1988, The Journal of bone and joint surgery. American volume.

[22]  L. Claes,et al.  Mechanical boundary conditions of fracture healing: borderline indications in the treatment of unreamed tibial nailing. , 2001, Journal of biomechanics.

[23]  M. Doblaré,et al.  Computational comparison of reamed versus unreamed intramedullary tibial nails , 2007, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[24]  R. Brand,et al.  The sensitivity of muscle force predictions to changes in physiologic cross-sectional area. , 1986, Journal of biomechanics.

[25]  J. Winters Hill-Based Muscle Models: A Systems Engineering Perspective , 1990 .

[26]  Jack M. Winters,et al.  Multiple Muscle Systems: Biomechanics and Movement Organization , 2011 .

[27]  Georg N Duda,et al.  Mechanical conditions in the internal stabilization of proximal tibial defects. , 2002, Clinical biomechanics.

[28]  E. Schneider,et al.  Variability of femoral muscle attachments. , 1996, Journal of biomechanics.

[29]  R. Woledge,et al.  The forces in the distal femur and the knee during walking and other activities measured by telemetry. , 1998, The Journal of arthroplasty.