Rotational x-ray angiography: a method for intra-operative volume imaging of the left-atrium and pulmonary veins for atrial fibrillation ablation guidance

Catheter-based ablation in the left atrium and pulmonary veins (LAPV) for treatment of atrial fibrillation in cardiac electrophysiology (EP) are complex and require knowledge of heart chamber anatomy. Electroanatomical mapping (EAM) is typically used to define cardiac structures by combining electromagnetic spatial catheter localization with surface models which interpolate the anatomy between EAM point locations in 3D. Recently, the incorporation of pre-operative volumetric CT or MR data sets has allowed for more detailed maps of LAPV anatomy to be used intra-operatively. Preoperative data sets are however a rough guide since they can be acquired several days to weeks prior to EP intervention. Due to positional and physiological changes, the intra-operative cardiac anatomy can be different from that depicted in the pre-operative data. We present an application of contrast-enhanced rotational X-ray imaging for CT-like reconstruction of 3D LAPV anatomy during the intervention itself. Depending on the heart size a single or two selective contrastenhanced rotational acquisitions are performed and CT-like volumes are reconstructed with 3D filtered back projection. In case of dual injection, the two volumes depicting the left and right portions of the LAPV are registered and fused. The data sets are visualized and segmented intra-procedurally to provide anatomical data and surface models for intervention guidance. Our results from animal and human experiments indicate that the anatomical information from intra-operative CT-like reconstructions compares favorably with preacquired imaging data and can be of sufficient quality for intra-operative guidance.

[1]  Onno Wink,et al.  Randomized study of the safety and clinical utility of rotational angiography versus standard angiography in the diagnosis of coronary artery disease , 2004, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[2]  O. Alfieri,et al.  Atrial Electroanatomic Remodeling After Circumferential Radiofrequency Pulmonary Vein Ablation: Efficacy of an Anatomic Approach in a Large Cohort of Patients With Atrial Fibrillation , 2001, Circulation.

[3]  Jeremy N Ruskin,et al.  Images in cardiovascular medicine. Integration of 3-dimensional cardiac computed tomography images with real-time electroanatomic mapping to guide catheter ablation of atrial fibrillation. , 2005, Circulation.

[4]  J. Ruskin,et al.  Integration of cardiac magnetic resonance imaging with three-dimensional electroanatomic mapping to guide left ventricular catheter manipulation: feasibility in a porcine model of healed myocardial infarction. , 2004, Journal of the American College of Cardiology.

[5]  Rebecca Fahrig,et al.  AB41-5: Accuracy of cardiac 3-D image reconstruction of the pulmonary veins using a flat-panel C-arm CT system , 2006 .

[6]  William E. Lorensen,et al.  Marching cubes: A high resolution 3D surface construction algorithm , 1987, SIGGRAPH.

[7]  Günter Lauritsch,et al.  Towards cardiac C-arm computed tomography , 2006, IEEE Transactions on Medical Imaging.

[8]  Hugh Calkins,et al.  Anatomic Stereotactic Catheter Ablation on Three-Dimensional Magnetic Resonance Images in Real Time , 2003, Circulation.

[9]  Katja Zeppenfeld,et al.  Fusion of multislice computed tomography imaging with three-dimensional electroanatomic mapping to guide radiofrequency catheter ablation procedures. , 2005, Heart rhythm.

[10]  F. Maes,et al.  Cardiac Three-Dimensional Magnetic Resonance Imaging and Fluoroscopy Merging: A New Approach for Electroanatomic Mapping to Assist Catheter Ablation , 2005, Circulation.

[11]  H. Calkins,et al.  Real-Time Cardiac Catheter Navigation on Three-Dimensional CT Images , 2003, Journal of Interventional Cardiac Electrophysiology.

[12]  JasbirSra,et al.  Registration of Three-Dimensional Left Atrial Computed Tomographic Images With Projection Images Obtained Using Fluoroscopy , 2005 .

[13]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[14]  G. M. Chaudhry,et al.  Three-dimensional rotational angiography of the left atrium and esophagus--A virtual computed tomography scan in the electrophysiology lab? , 2007, Heart rhythm.

[15]  J Clémenty,et al.  Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. , 1998, The New England journal of medicine.

[16]  H. Halperin,et al.  Integrated Electroanatomic Mapping With Three-Dimensional Computed Tomographic Images for Real-Time Guided Ablations , 2006, Circulation.