The force-length relationship of a muscle-tendon complex: experimental results and model calculations

SummaryModels are useful when studying how architectural and physiological properties of muscle-tendon complexes are related to function, because they allow for the simulation of the behaviour of such complexes during natural movements. In the construction of these models, evaluation of their accuracy is an important step. In the present study, a model was constructed to calculate the isometric force-length relationship of the rat extensor digitorum longus muscle-tendon complex. The model is based on the assumption that a muscle-tendon complex is a collection of independent units, each consisting of a muscle fibre in series with a tendon fibre. By intention, values for model parameters were derived indirectly, using only the measured maximal isometric tetanic force, the distance between origin and insertion at which it occurred (optimum lOI) and an estimate of muscle fibre optimal length. The accuracy of the calculated force-length relationship was subsequently evaluated by comparing it to the relationship measured in isometric tetanic contractions of a real complex in the rat. When the length of distal muscle fibres, measured during isometric contraction at optimal lOI of the whole complex, was used as an estimate for muscle fibre optimal length of all muscle fibre — tendon fibre units in the model, the calculated relationship was too narrow. That is, both on the ascending limb and on the descending limb the calculated tetanic force was lower than the measured tetanic force. These discrepancies could be explained partly by assuming that a spread existed in optimal lengths of the units, and that the units which contained the distal muscle fibres were acting below their optimal length during isometric contraction at optimal lOI of the whole complex.

[1]  M. Bobbert,et al.  A model of the human triceps surae muscle-tendon complex applied to jumping. , 1986, Journal of biomechanics.

[2]  D. Stephenson,et al.  Dissociation of force from myofibrillar MgATPase and stiffness at short sarcomere lengths in rat and toad skeletal muscle. , 1989, The Journal of physiology.

[3]  R. D. Woittiez,et al.  A three‐dimensional muscle model: A quantified relation between form and function of skeletal muscles , 1984, Journal of morphology.

[4]  Determinants of length range of active force exertion by muscle , 1988, Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[5]  A. Huxley,et al.  The variation in isometric tension with sarcomere length in vertebrate muscle fibres , 1966, The Journal of physiology.

[6]  S. Walker,et al.  I segment lengths and thin filament periods in skeletal muscle fibers of the rhesus monkey and the human , 1974, The Anatomical record.

[7]  A multipurpose muscle ergometer. , 1987, Journal of biomechanics.

[8]  P A Huijing,et al.  Architecture of the human gastrocnemius muscle and some functional consequences. , 1985, Acta anatomica.

[9]  G H Pollack,et al.  The sarcomere length-tension relation in skeletal muscle , 1978, The Journal of General Physiology.

[10]  Peter A. Huijing,et al.  Properties of tendinous structures of rat EDL muscle-tendon complex , 1989 .

[11]  J A Stephens,et al.  The motor units of cat medial gastrocnemius: Electrical and mechanical properties as a function of muscle length , 1975, Journal of morphology.

[12]  G J van Ingen Schenau,et al.  Isokinetic plantar flexion: experimental results and model calculations. , 1990, Journal of biomechanics.

[13]  E. Otten Concepts and Models of Functional Architecture in Skeletal Muscle , 1988, Exercise and sport sciences reviews.