Time-Domain Calibrated Measurements of Wideband Multisines Using a Large-Signal Network Analyzer

This paper presents a calibrated measurement technique that enables phase and magnitude measurements of wideband multisines. This study is based on the use of a large-signal network analyzer (LSNA) performing harmonic sub-sampling and a fine frequency grid (20 MHz) comb generator calibrated using a high-frequency 50-GHz equivalent-time sampling scope. This comb generator is used as a harmonic phase reference generator for the calibration of the LSNA. The research reported here is applied to L-band multisine measurements, but it can be extended to higher microwave frequencies. The motivation of this study is to measure the multipactor phenomena effect in output RF multiplexers of satellite payloads.

[1]  J.B. Scott,et al.  Mixer-based, vector-corrected, vector signal/network analyzer offering 300kHz-20GHz bandwidth and traceable phase response , 2005, IEEE MTT-S International Microwave Symposium Digest, 2005..

[2]  Jan Verspecht,et al.  Calibration of a Measurement System for High Frequency Nonlinear Devices , 1999 .

[3]  Yves Rolain,et al.  Design of narrowband, high-resolution multisines , 1996 .

[4]  P. Roblin,et al.  New Ultra-fast Real-time Active Load-pull Measurements for High Speed RF Power Amplifier Design , 2007, 2007 IEEE/MTT-S International Microwave Symposium.

[5]  Jacques Sombrin,et al.  A MULTIPACTOR THRESHOLD IN WAVEGUIDES: THEORY AND EXPERIMENT , 2006 .

[6]  W. Van Moer,et al.  An improved broadband conversion scheme for the large signal network analyzer , 2005, IEEE MTT-S International Microwave Symposium Digest, 2005..

[7]  Bumman Kim,et al.  Measurement of two-tone transfer characteristics of high-power amplifiers , 2001 .

[8]  P. J. Tasker Non-linear vector network analyser NLVNA , 2005 .

[9]  T.M. Souders,et al.  The effects of timing jitter in sampling systems , 1989, 6th IEEE Conference Record., Instrumentation and Measurement Technology Conference.

[10]  Yves Rolain,et al.  An identification technique for data acquisition characterization in the presence of nonlinear distortions and time base distortions , 2001, IEEE Trans. Instrum. Meas..

[11]  J.B. Scott,et al.  Wide-bandwidth, vector-corrected measurement with high spurious-free dynamic range , 2005, 65th ARFTG Conference Digest, 2005. Spring 2005.

[12]  U. Lott Measurement of magnitude and phase of harmonics generated in nonlinear microwave two-ports , 1989 .

[13]  Denis Barataud,et al.  Measurements of time-domain voltage/current waveforms at RF and microwave frequencies based on the use of a vector network analyzer for the characterization of nonlinear devices-application to high-efficiency power amplifiers and frequency-multipliers optimization , 1998, IEEE Trans. Instrum. Meas..

[14]  A. Cidronali,et al.  Extraction of conversion matrices for P-HEMTs based on vectorial large-signal measurements , 2003, IEEE MTT-S International Microwave Symposium Digest, 2003.

[15]  J.M. Morgan,et al.  Calibrating electro-optic sampling systems , 2001, 2001 IEEE MTT-S International Microwave Sympsoium Digest (Cat. No.01CH37157).

[16]  T. Reveyrand,et al.  Calibrated measurements of waveforms at internal nodes of MMICs with a LSNA and high impedance probes , 2003, Conference, 2003. Fall 2003. 62nd ARFTG Microwave Measurements.

[17]  Kate A. Remley,et al.  Bandwidth Extension using Stitching Approach , 2005 .

[18]  M. El Yaagoubi,et al.  Accurate phase measurements of broadband Multitone signals using a specific configuration of a Large Signal Network Analyzer , 2006, 2006 IEEE MTT-S International Microwave Symposium Digest.

[19]  A. Barel,et al.  A microwave multisine with known phase for the calibration of narrowbanded nonlinear vectorial network analyzer measurements , 1998, 1998 IEEE MTT-S International Microwave Symposium Digest (Cat. No.98CH36192).

[20]  J. Wood,et al.  Extended NVNA bandwidth for long-term memory measurements , 2004, 2004 IEEE MTT-S International Microwave Symposium Digest (IEEE Cat. No.04CH37535).

[21]  Ce-Jun Wei,et al.  Internal-node waveform analysis of MMIC power amplifiers , 1995 .

[22]  T. M. Souders,et al.  The effects of timing jitter in sampling systems , 1989 .

[23]  F. De Groote,et al.  An improved coupling method for time domain load-pull measurements , 2005, 65th ARFTG Conference Digest, 2005. Spring 2005.

[24]  J. Verspecht,et al.  Individual characterization of broadband sampling oscilloscopes with a 'nose-to-nose' calibration procedure , 1993, 1993 IEEE Instrumentation and Measurement Technology Conference.

[25]  J. Verspecht,et al.  An improved coupling method for time domain load-pull measurements , 2005, 2005 European Microwave Conference.

[26]  Yves Rolain,et al.  An Improved Broadband Conversion Scheme for the Large-Signal Network Analyzer , 2009, IEEE Transactions on Instrumentation and Measurement.

[27]  Yves Rolain,et al.  Proving the usefulness of a 3-port nonlinear vectorial network analyser through mixer measurements , 2003, IEEE MTT-S International Microwave Symposium Digest, 2003.

[28]  Yves Rolain,et al.  Signal reconstruction for non-equidistant finite length sample sets: a "KIS" approach , 1998, IEEE Trans. Instrum. Meas..

[29]  J.C.M. Hwang Internal waveform probing of HBT and HEMT MMIC power amplifiers , 2002, 60th ARFTG Conference Digest, Fall 2002..