The influence of occlusal loading location on stresses transferred to implant-supported prostheses and supporting bone: A three-dimensional finite element study.

STATEMENT OF PROBLEM Information about the influence of occlusal loading by location on the stress distribution in an implant-supported fixed partial denture and supporting bone tissue is limited. PURPOSE The purpose of this study was to investigate the effect of loading at 1 to 3 different locations on the occlusal surface of a tooth on the stress distributions in an implant-supported mandibular fixed partial denture (FPD) and surrounding bone, using 3-dimensional finite element analysis. MATERIAL AND METHODS A 3-dimensional finite element model of a mandibular section of bone (Type 2) with missing second premolar and its superstructures were used in this study. A 1-piece 4.1 x 10-mm screw-shape ITI dental implant system (solid implant) was modeled for this study. Cobalt-Chromium (Wiron 99) was used as the crown framework material and porcelain was used for occlusal surface. The implant and its superstructure were simulated in a Pro/Engineer 2000i program. Total loads at 300 N were applied at the following locations: 1) tip of buccal cusp (300 N); 2) tip of buccal cusp (150 N) and distal fossa (150 N); or 3) tip of buccal cusp (100 N), distal fossa (100 N), and mesial fossa (100 N). RESULTS The results demonstrated that vertical loading at 1 location resulted in high stress values within the bone and implant. Close stress levels were observed within the bone for loading at 2 locations and 3 locations; the former created the most extreme stresses and the latter the most even stresses within the bone. With loading at 2 or 3 locations, stresses were concentrated on the framework and occlusal surface of the FPD, and low stresses were distributed to the bone. CONCLUSION For the loading conditions investigated, the optimal combination of vertical loading was found to be loading at 2 or 3 locations which decreased the stresses within the bone. In this situation, von Mises stresses were concentrated on the framework and occlusal surface of the FPD.

[1]  M. Çehreli,et al.  The influence of functional forces on the biomechanics of implant-supported prostheses--a review. , 2002, Journal of dentistry.

[2]  F. Mante,et al.  Evaluating parameters of osseointegrated dental implants using finite element analysis--a two-dimensional comparative study examining the effects of implant diameter, implant shape, and load direction. , 1998, The Journal of oral implantology.

[3]  R. Jaffin,et al.  The excessive loss of Branemark fixtures in type IV bone: a 5-year analysis. , 1991, Journal of periodontology.

[4]  G. Liu,et al.  Application of finite element analysis in implant dentistry: a review of the literature. , 2001, The Journal of prosthetic dentistry.

[5]  P. Branemark,et al.  Long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws. , 1990, The International journal of oral & maxillofacial implants.

[6]  I Naert,et al.  The influence of static and dynamic loading on marginal bone reactions around osseointegrated implants: an animal experimental study. , 2001, Clinical oral implants research.

[7]  T Suetsugu,et al.  Two-dimensional FEM analysis of hydroxyapatite implants: diameter effects on stress distribution. , 1990, The Journal of oral implantology.

[8]  N Matsumoto,et al.  Influence of bone quality on the stress distribution. An in vitro experiment. , 1997, Clinical oral implants research.

[9]  K Tsuga,et al.  The effectiveness of element downsizing on a three-dimensional finite element model of bone trabeculae in implant biomechanics. , 1999, Journal of oral rehabilitation.

[10]  F. A. Peyton,et al.  Current evaluation of plastics in crown and bridge prosthesis , 1963 .

[11]  H. Iplikçioğlu,et al.  Comparative evaluation of the effect of diameter, length and number of implants supporting three-unit fixed partial prostheses on stress distribution in the bone. , 2002, Journal of dentistry.

[12]  S C Bayne,et al.  3D-FEA of osseointegration percentages and patterns on implant-bone interfacial stresses. , 1997, Journal of dentistry.

[13]  D. Cochran,et al.  The scientific basis for and clinical experiences with Straumann implants including the ITI Dental Implant System: a consensus report. , 2000, Clinical oral implants research.

[14]  S. Timoshenko,et al.  Elements Of Strength Of Materials , 1935 .

[15]  L A Weinberg,et al.  A comparison of implant/prosthesis loading with four clinical variables. , 1995, The International journal of prosthodontics.

[16]  B Rangert,et al.  Bending overload and implant fracture: a retrospective clinical analysis. , 1995, The International journal of oral & maxillofacial implants.

[17]  Ismail Yh,et al.  Comparison of two-dimensional and three-dimensional finite element analysis of a blade implant. , 1987 .

[18]  George A. Zarb,et al.  Tissue-Integrated Prostheses: Osseointegration in Clinical Dentistry , 1985 .

[19]  Holmes Dc,et al.  Influence of bone quality on stress distribution for endosseous implants. , 1997 .

[20]  J. Kuiper,et al.  Stress distribution around dental implants: influence of superstructure, length of implants, and height of mandible. , 1992, The Journal of prosthetic dentistry.

[21]  W C Van Buskirk,et al.  The Elastic Properties of a Human Mandible , 1987, Advances in dental research.

[22]  S. Bayne,et al.  Three-dimensional finite element analysis of stress-distribution around single tooth implants as a function of bony support, prosthesis type, and loading during function. , 1996, The Journal of prosthetic dentistry.

[23]  I Lewinstein,et al.  Finite element analysis of a new system (IL) for supporting an implant-retained cantilever prosthesis. , 1995, The International journal of oral & maxillofacial implants.

[24]  K J Anusavice,et al.  Three-dimensional finite element analysis of glass-ceramic dental crowns. , 1990, Journal of biomechanics.

[25]  C. Watson,et al.  Finite element analysis of fixed prostheses attached to osseointegrated implants. , 1990, Quintessence international.

[26]  H. C. Lundeen,et al.  Occlusal forces during chewing--influences of biting strength and food consistency. , 1981, The Journal of prosthetic dentistry.

[27]  C. Stohler,et al.  Determining the force absorption quotient for restorative materials used in implant occlusal surfaces. , 1992, The Journal of prosthetic dentistry.

[28]  Chapman Rj Principles of occlusion for implant prostheses: guidelines for position, timing, and force of occlusal contacts. , 1989 .

[29]  P I Brånemark,et al.  A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. , 1981, International journal of oral surgery.