Fluoroscopic evaluation of diaphragmatic motion reduction with a respiratory gated radiotherapy system

We report on initial patient studies to evaluate the performance of a commercial respiratory gating radiotherapy system. The system uses a breathing monitor, consisting of a video camera and passive infrared reflective markers placed on the patient's thorax, to synchronize radiation from a linear accelerator with the patient's breathing cycle. Six patients receiving treatment for lung cancer participated in a study of system characteristics during treatment simulation with fluoroscopy. Breathing synchronized fluoroscopy was performed initially without instruction, followed by fluoroscopy with recorded verbal instruction (i.e., when to inhale and exhale) with the tempo matched to the patient's normal breathing period. Patients tended to inhale more consistently when given instruction, as assessed by an external marker movement. This resulted in smaller variation in expiration and inspiration marker positions relative to total excursion, thereby permitting more precise gating tolerances at those parts of the breathing cycle. Breathing instruction also reduced the fraction of session times having irregular breathing as measured by the system software, thereby potentially increasing the accelerator duty factor and decreasing treatment times. Fluoroscopy studies showed external monitor movement to correlate well with that of the diaphragm in four patients, whereas time delays of up to 0.7 s in diaphragm movement were observed in two patients with impaired lung function. From fluoroscopic observations, average patient diaphragm excursion was reduced from 1.4 cm (range 0.7–2.1 cm) without gating and without breathing instruction, to 0.3 cm (range 0.2–0.5 cm) with instruction and with gating tolerances set for treatment at expiration for 25% of the breathing cycle. Patients expressed no difficulty with following instruction for the duration of a session. We conclude that the external monitor accurately predicts internal respiratory motion in most cases; however, it may be important to check with fluoroscopy for possible time delays in patients with impaired lung function. Furthermore, we observe that verbal instruction can improve breathing regularity, thus improving the performance of gated treatments with this system. PACS number(s): 87.53.–j, 87.62.+n

[1]  K. Ohara,et al.  Irradiation synchronized with respiration gate. , 1989, International journal of radiation oncology, biology, physics.

[2]  Chester R. Ramsey,et al.  Clinical experience with a commercial respiratory gating system , 2000 .

[3]  H Shirato,et al.  Three-dimensional movement of a liver tumor detected by high-speed magnetic resonance imaging. , 1999, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[4]  Clinical experience with a system for pediatric respiratory gated radiotherapy , 1998 .

[5]  A method for measuring lung shape in electronic portal images during gated treatment , 2000 .

[6]  D A Jaffray,et al.  Active breathing control (ABC) for Hodgkin's disease: reduction in normal tissue irradiation with deep inspiration and implications for treatment. , 2000, International journal of radiation oncology, biology, physics.

[7]  B. Murray,et al.  Held-breath self-gating technique for radiotherapy of non-small-cell lung cancer: a feasibility study. , 2001, International journal of radiation oncology, biology, physics.

[8]  H. Mostafavi,et al.  Breathing-synchronized radiotherapy program at the University of California Davis Cancer Center. , 2000, Medical physics.

[9]  J Moxham,et al.  The respiratory muscles. , 1988, Praxis und Klinik der Pneumologie.

[10]  C. Pelizzari,et al.  A video-based technique to gate radiotherapy treatments for respiration , 1998 .

[11]  R K Ten Haken,et al.  The reproducibility of organ position using active breathing control (ABC) during liver radiotherapy. , 2001, International journal of radiation oncology, biology, physics.

[12]  J. Verschakelen,et al.  Normal thoracoabdominal motions. Influence of sex, age, posture, and breath size. , 1995, American journal of respiratory and critical care medicine.

[13]  T. Landberg,et al.  What margins should be added to the clinical target volume in radiotherapy treatment planning for lung cancer? , 1998, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[14]  J. Itami,et al.  Target volume definition for upper abdominal irradiation using CT scans obtained during inhale and exhale phases. , 2000, International journal of radiation oncology, biology, physics.

[15]  K. Lam,et al.  Uncertainties in CT-based radiation therapy treatment planning associated with patient breathing. , 1996, International journal of radiation oncology, biology, physics.

[16]  2211 Comparison of different respiratory levels in the treatment of lung cancer: Implications for gated treatment , 1999 .

[17]  S Minohara,et al.  Respiratory gated irradiation system for heavy-ion radiotherapy. , 2000, International journal of radiation oncology, biology, physics.

[18]  C C Ling,et al.  The deep inspiration breath-hold technique in the treatment of inoperable non-small-cell lung cancer. , 2000, International journal of radiation oncology, biology, physics.

[19]  C. Ramsey,et al.  Clinical efficacy of respiratory gated conformal radiation therapy. , 1999, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[20]  H Shirato,et al.  High-speed magnetic resonance imaging for four-dimensional treatment planning of conformal radiotherapy of moving body tumors. , 2000, International journal of radiation oncology, biology, physics.

[21]  G J Kutcher,et al.  Deep inspiration breath-hold technique for lung tumors: the potential value of target immobilization and reduced lung density in dose escalation. , 1999, International journal of radiation oncology, biology, physics.

[22]  E. L. Keatley,et al.  Computer Automated Quantification of Respiratory Motion in a Fluoroscopic Movie , 2000 .

[23]  P. Macklem,et al.  The respiratory muscles. , 1982, The New England journal of medicine.

[24]  C. Ling,et al.  Technical aspects of the deep inspiration breath-hold technique in the treatment of thoracic cancer. , 2000, International journal of radiation oncology, biology, physics.

[25]  M. Halliwell,et al.  Ultrasound quantitation of respiratory organ motion in the upper abdomen. , 1994, The British journal of radiology.

[26]  J. Wong,et al.  The use of active breathing control (ABC) to reduce margin for breathing motion. , 1999, International journal of radiation oncology, biology, physics.

[27]  W. Stanford,et al.  Analysis of movement of intrathoracic neoplasms using ultrafast computerized tomography. , 1990, International journal of radiation oncology, biology, physics.

[28]  D A Jaffray,et al.  The effects of intra-fraction organ motion on the delivery of dynamic intensity modulation. , 1998, Physics in medicine and biology.

[29]  P Poulet,et al.  Oxygen consumption through metabolism and photodynamic reactions in cells cultured on microbeads. , 2000, Physics in medicine and biology.

[30]  H. Shirato,et al.  Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor. , 2000, International journal of radiation oncology, biology, physics.

[31]  K. Lam,et al.  Improvement of CT-based treatment-planning models of abdominal targets using static exhale imaging. , 1998, International journal of radiation oncology, biology, physics.

[32]  H. Kubo,et al.  Respiration gated radiotherapy treatment: a technical study. , 1996, Physics in medicine and biology.

[33]  Linda Hong,et al.  The effects of intra-fraction organ motion on the delivery of intensity-modulated field with a multileaf collimator. , 2003, Medical physics.

[34]  C. Ramsey,et al.  A comparison of beam characteristics for gated and nongated clinical x-ray beams. , 1999, Medical physics.

[35]  Paul J. Keall,et al.  Preliminary results from a study of a respiratory motion tracking system: underestimation of target volume with conventional CT simulation , 2000 .

[36]  R. K. Münch,et al.  A novel tracking technique for the continuous precise measurement of tumour positions in conformal radiotherapy. , 2000, Physics in medicine and biology.

[37]  John F. Nunn,et al.  Nunn's Applied Respiratory Physiology , 1993 .